Sealing and strengthening of the subsoil by injection is a major issue in the field of geotechnical engineering. This involves also jet grouting, which allows creating columns of grouted soil by eroding and mixing the in-situ soil with a thin cement suspension. A general difficulty of this method is to predict the column diameter and its material strength. Here, we present two-dimensional finite-difference numerical simulation results of a promising non-destructive quality assurance testing tool to evaluate the diameter of jet grout columns. This approach incorporates crosshole and downhole seismic measurements. Preliminary tests showed that this tool is applicable under real site conditions.
In this paper we present results of our recent efforts to understand the mechanical interface behaviour of single-walled carbon nanotubes (CNTs) embedded in metal matrices. We conducted experimental pull-out tests of CNTs embedded in Pd or Au and found Maximum forces in the range 10 - 102 nN. These values are in good agreement with forces obtained from molecular Dynamics simulations taking into account surface functional Groups (SFGs) covalently linked to the CNT material. The dominant failure mode in experiment is a CNT rupture, which can be explained with the presence of SFGs. To qualify the existence of SFGs on our used CNT material, we pursue investigations by means of fluorescence labeling of surface species in combination with Raman imaging. We also report of a tensile test system to perform pull-out tests inside a transmission electron microscope to obtain in situ images of CNT-metal interfaces under mechanical loads at the atomic scale.
CONRAD-2 is an imaging instrument using low-energy (cold) neutrons. The instrument is installed at the end of a curved neutron guide which avoids the direct line of sight towards the reactor core. This ensures a very low background of high-energy neutrons and. photons at the sample position. The cold neutron beam provides a wavelength range which is suitable for phase-and diffraction-contrast imaging such as grating interferometry and Bragg edge mapping. The instrument is well suited for high resolution imaging due to the high efficiency of the very thin scintillators that can be used for the detection of cold neutrons. An instrument upgrade was performed recently as a part of an upgrade program for the cold neutron instrumentation at HZB. The parameters of the instrument as well as some research highlights will be presented.
An experimental investigation has been carried out to characterize and discriminate seven saffron samples and to verify their declared geographical origin using a voltammetric electronic tongue (VE-tongue). The ability of multivariable analysis methods such as Principal Component Analysis (PCA), Hierarchical Cluster Analysis (HCA) to classify the saffron samples according to their geographical origin have been investigated. A good discrimination has reached using PCA and HCA in the VE-tongue characterization case. Furthermore, cross validation and Partial Least Square (PLS) techniques were applied in order to build suitable management and prediction models for the determination of safranal concentration in saffron samples based on SPME-GC-MS and UV-Vis Spectrophotometry. The obtained results reveals that some relationships were established between the VE-tongue signal, SPMEGC-MS and UV-Vis spectrophotometry methods to predict safranal concentration levels in saffron samples by using the PLS model. In the light of these results, we can say that the proposed electronic system offer a fast, simple and efficient tool to recognize the declared geographical origin of the saffron samples.
Laser-induced breakdown spectroscopy (LIBS) is a combination of plasma generation on the sample surface by a high power laser pulse and optical emission spectroscopy (OES). It is a direct measurement method without an extensive sample preparation. Concrete is a multi phase system. With LIBS it is possible to distinguish the different phases and based on that to correlate the chloride content to the cement mass. This is done by scanning the surface with a resolution of up to 0.1 mm. The high measurement frequency of 100 Hz or even higher allows the in-situ visualization of the chloride content over the measured area. With a calibration a quantification of chloride concentration is possible. As an example the LIBS measurement on a 50 mm by 70 mm area with a resolution of 0.5 mm and the visualization of the chloride distribution takes only 10 minutes. Additionally it is possible to evaluate the carbonation depth from the same measurement. Examples of practical application to determine the chloride-to-cement-content on concrete samples are presented. The possibilities and the limitations of LIBS are discussed.