Due to the demand of monitoring the water quality regarding emerging pollutants, such as drug residues, selective, high-throughput and multi-target analytical methods must be established. On the one hand, the influence of sewage on natural surface waters must be routinely monitored. On the other hand, estimation of removal efficiencies of pollutants, such as drug residues, is in the focus of industrial and public wastewater treatment. Immunoassays, such as ELISA, offer the possibility to be highly sensitive and selective due to the high target affine and specific recognition of antibodies to target molecules. Batch-wise processing in microtiter plates allow the necessary high-throughput, but only a single analyte can be determined within one measurement.
To overcome these disadvantages, we developed a four-plex micro-bead based flow cytometric assay, which is adaptable for the microtiter plate format. The modular and self-prepared bead support consists of polystyrene-core-silica-shell particles. While the polystyrene core is used for encoding, by introducing different amounts of fluorescent dyes, the silica-shell creates a solid-support for the immunoassay: The target analytes, three drugs, carbamazepine, diclofenac and caffeine and the f ecal marker isolithocholic acid are covalently coupled to amino-groups on the surface via NHS-chemistry. A competitive immunoassay is subsequently conducted in a simple mix-and-read procedure. Finally, we could use SAFIA to assess the influent of treated and untreated waste water on the Douro river estuary in Portugal. The results of the analysis are comparable to ELISA. However, measurements could be carried out in 25% the time of analysis.
Monitoring water quality regarding emerging pollutants, such as drug residues, demands for selective, high-throughput and multi-target analytical methods. On the one hand, the influence of sewage on natural surface waters must be routinely monitored. On the other hand, estimation of removal efficiencies of pollutants, such as drug residues, is in the focus of industrial and public wastewater treatment. Immunoassays, such as ELISA, offer the possibility to be highly sensitive and selective due to the high target affinity and specificity of target recognition by antibodies. Batch-wise processing in microtiter plates allows for the necessary high-throughput, but only a single analyte can be determined within one measurement.
To overcome these disadvantages, we developed a four-plex Suspension Array Fluorescence Immunoassay (SAFIA), which is adaptable for the microtiter plate format. The modular and self-prepared bead support consists of polystyrene-core silica-shell microparticles. While the polystyrene core is used for encoding, by introducing different amounts of fluorescent dyes, the silica shell creates a solid-support for the immunoassay: the target analytes, three drugs, carbamazepine, diclofenac and caffeine, and the fecal marker isolithocholic acid are covalently coupled to amino groups on the surface via NHS chemistry. Specific recognition of these haptens is accomplished by further introduction of PEG moieties, suppressing non-specific binding. A competitive immunoassay is subsequently conducted in a simple mix-and-read procedure, eliminating the demand for laborious washing steps and decreasing time-to-result. An automated flow cytometer is used for simultaneous decoding and quantification.
After optimization, the SAFIA showed limits of detection for all analytes in the low µg L 1 range, meeting the sensitivity criteria for wastewater analysis. Then, applicability of the SAFIA was studied on real wastewater samples from three different wastewater treatment plants in Berlin. The results were in good comparability to LC-MS/MS indicating high matrix stability. Moreover, the accuracy of the assay exceeded that of the respective ELISA. Finally, we used SAFIA to assess the influent of treated and untreated wastewater on the Douro river estuary in Portugal. The obtained results of the analysis were comparable to ELISA. However, the measurements by SAFIA could be carried out in one quarter the time of analysis required for ELISA.
Acknowledgements: The authors acknowledge financial support from Deutscher Akademischer Austauschdienst and from Fundação das Universidades Portuguesas under the protocol CRUP-DAAD (Ações Integradas Luso-Alemãs nºE-20/16, DAAD Zuwendungsvertrag 57212899).
The improvement of immunoanalytical methods for the determination of pharmaceuticals in wastewaters is a crucial yet challenging endeavor. In this work, the development of an automated miniaturized ELISA based on micro-Bead Injection Spectroscopy (μ-BIS) [1] for the determination of carbamazepine, a widely employed anti-epileptic drug and emergent pollutant [2], was pursued.
The experimental workflow comprised the offline functionalization of Sepharose beads with specific anti-CBZ antibodies via affinity immobilization using protein G, and 3 online steps inside the microfluidic analyzer lab-on-valve (LOV): I) packing of the bead column into the detection unit; II) sequential percolation of sample and a CBZ competitor- labeled with horseradish peroxidase (tracer) through the bead column; and III) on-column colorimetric detection employing the enzyme substrate 3,3’,5,5’-tetramethylbenzidine. After each analysis, the bead column was discarded, and the flow cell was washed before receiving new beads.
The elimination of manual washing steps is a novel feature compared to batch-wise ELISA, making the method less error-prone and therefore more robust. The replacement of the solid support prevents memory effects and cross-contamination between runs. The use of microparticles as solid support for the molecular recognition elements accounts for high area-to-volume ratios, and low molecular diffusion distances. For that reason, time-to-result was reduced from several hours to less than 10 min. The consumption of reagents was also very low. For instance, only ca. 200 μg of solid support and 900 ng of anti-CBZ antibody were required per determination. At last, the versatility of the LOV platform offers the possibility of adapting the assay to other relevant pharmaceuticals and anthropogenic markers in water.
Acknowledgements: Inês I. Ramos thanks FCT (Fundação para a Ciência e a Tecnologia) and POPH (Programa Operacional Potencial Humano) for her grant (SFRH/BD/97540/2013). This work received financial support from the European Union (FEDER funds POCI/01/0145/FEDER/007265) and National Funds (FCT/MEC - Ministério da Educação e Ciência) under the Partnership Agreement PT2020 UID/QUI/50006/2013. Financial support from Deutscher Akademischer Austauschdienst and from Fundação das Universidades Portuguesas under the protocol CRUP-DAAD (Ações Integradas Luso-Alemãs nºE-20/16) is also acknowledged.
[1] Gutzman, Y.; Carrol, A. D. Analyst 2006, 131, 809.
[2] Murray, K. E.; Thomas, S. M.; Bodour, A. A. Environ. Pollut. 2010, 158, 3462.
Perfluorocarboxylic acids (PFCAs) are a family of compounds that consist of a fully perfluorinated carbon backbone and a carboxylic acid moiety1. PFCAs have been classified as substances of very high concern by REACH regulations due to their persistence in the environment, non biodegradability and toxicological effects2. Thus, there is significant interest in detecting PFCAs in ground, waste, surface and drinking water. Fluorescence detection is a portable, easy-to-operate and cost-effective alternative, enabling the onsite detection of these analytes e.g., with miniaturized fluidic sensors.
Here, a guanidine benzoxadiazole (BD) dye covalently attached to a polymerizable methacrylate unit was developed for the integration of the dye into polymers and on surfaces. The response behavior of the dye toward PFCAs was assessed in monophasic (EtOAc) and biphasic (EtOAc-H2O) solvent systems, the biphasic system being advantageous for the extraction of the hydrophobic organic acids from the aqueous phase.
The BD dye was integrated into sensory silica core-polymer shell particles for the sensing of PFCAs directly in aqueous media. Submicron SiO2 particles were functionalized with 3 (trimethoxysilyl)propyl methacrylate followed by radical polymerization with the BD dye and ethylene glycol dimethacrylate. TEM images showed a homogeneous polymer shell with a thickness of 75±2 nm.
By incorporating the BD dye into core-shell particles, lower limits of detection (1.52 µM for perfluorooctanoic acid, PFOA) were achieved if compared to the use of the neat BD dye in a biphasic assay (17.3 µM for PFOA), and excellent discrimination against inorganic acids thanks to the hydrophobic polymer shell. The particle sensory platform has proven to be an alternative for the sensing of PFCAs directly in water.
Oxidative degradation processes of tetrabromobisphenol A (TBBPA), a brominated flame retardant (BFR) in wood, plastics and electronics, were investigated by electrochemistry (EC) coupled online to electrospray ionization mass spectrometry (ESI/MS). Oxidative phase I and II metabolites production was achieved using an electrochemical flow-through cell equipped with a boron doped diamond electrode. Structural elucidation and prediction of oxidative metabolism pathways of TBBPA according to type II ipso-substitution were based on retention time, m/z ratio in negative mode and fragmentation pattern. Using the data obtained through high resolution MS analysis and the identification of single electron transfer (SET) as the initial step of a two-electron oxidation provided the necessary information to propose a mechanism for the electrochemical oxidation of TBBPA. Oxidation reactions involving aromatic hydroxylation and β-scission were the main degradation observed when studying the electrochemical behavior of TBBPA. Computational chemistry experiments using density functional theory (DFT) allowed to identify mono-hydroxylated reaction intermediate and dismissed the mechanism involving two concurrent hydroxylation. TBBPA oxidation products were compared to known metabolites of its biological and environmental degradation confirming the ability of electrochemistry to simulate β-scission reactions.