Fatigue is one of the most prevalent issues, which directly influences the service life expectancy of concrete structures. Fatigue has been investigated for years for steel structures. However, recent findings suggest that concrete structures may also be significantly subjected to fatigue phenomena that could lead to premature failure of certain structural elements. To date, fatigue of reinforced concrete has been given little focus. Knowledge on the influence factors and durability/capacity effects on this material should be improved. Current technological means to measure fatigue in civil structures like bridges and wind turbines (both onshore and offshore) are outdated, imprecise and inappropriate.
Meanwhile, this topic has got much more attention as time-variant loading on concrete structures plays an increasing role, e.g. in bridges with increasing traffic and heavier trucks, and for wind turbines for renewable energy production, e.g. for offshore wind turbine support structures affected by wind and waves.
The European Innovative Training Networks (ITN) Marie Skłodowska-Curie Actions project INFRASTAR (Innovation and Networking for Fatigue and Reliability Analysis of Structures - Training for Assessment of Risk) provides research training for 12 PhD students. The project aims to improve knowledge for optimizing the design of new structures as well as for more realistic verification of structural safety and more accurate prediction of the remaining fatigue lifetime of existing concrete structures.
First, the INFRASTAR research framework is detailed. Then it will be exemplified through the presentation of the major results of the four PhD students involved in the work package dealing with auscultation and monitoring. This includes the development and improvement of Fiber Optics (FO) and Coda Wave Interferometry (CWI) for crack sizing and imagery, new sensor technologies and integration, information management, monitoring strategy for fatigue damage investigation and lifetime prediction.
Decades of non-destructive evaluation (NDE) for the quality assurance of concrete bridges revealed the necessity of developing procedures for building reference specimens for different defects. External objects have been widely used in specimen construction to represent defects. However, embedded materials can alter the actual defect characteristics, interrupting the NDE responses. This study proposes new approaches to fabricating reference specimens for reinforced concrete that feature substantial defects, including cracks, delamination, honeycombing and rebar corrosion, without external objects. As a result, realistic responses can be acquired to identify promising NDE methods for characterising actual deteriorations. The procedures were produced with the intent of being reproducible in any laboratory. Destructive and non-destructive testing methods were performed to verify the effectiveness of the processes in creating defects. This study provides research laboratories with techniques for
fabricating reference specimens for characterising defects and assessing the performance of NDE technologies.
The through-life management of our constantly ageing infrastructure is a basic requirement in order to ensure their structural safety and serviceability. Each structure experiences deterioration processes with time leading to a decrease of structural safety and serviceability. The design of new structures considers the expected deterioration for a defined period, the design service life. However, a frequent survey of structural safety controlling structural condition should be mandatory and a maintenance plan should be an integral part of the design. In addition, many structures have exceeded their design service life already or are very close to it leading to an increasing demand for condition assessment. On the one hand, assumptions made during design are not valid any more due to change of the loads, e.g., increasing traffic loads in terms of number and weights. On the other hand, design codes evolved over time in such a way that existing structures do not comply with today’s standards. In all these cases, the through-life management is an important tool to maintain the accessibility of existing structures with known reliability.
In line with the new Model Code for Concrete Structures, which includes guidance for both – design of new structures and assessment of existing structures, the Task Group 3.3 focused on the compilation of a state-of-the-art guideline for the through-life management of existing concrete structures, including:
Data acquisition by testing and monitoring techniques;
Condition assessment for the evaluation of existing structures;
Performance prediction using advanced methods;
Decision-making procedures to perform a complete assessment of existing structure.
The overall objective of the through-life management is the assessment of the current condition and the estimation of the remaining service life under consideration of all boundary conditions.
Motivation:
• Air-coupled ultrasound (AC-US) enables faster measurements in non-destructive testing for civil engineering
• Current state of the art: piezo and capacitive transducers are mostly used for AC US
• Currently >99.9% sound intensity loss due to impedance mismatches
Innovation:
• Fluidic transducers generate US (30-60 kHz) by rapid switching of a supersonic jet
• Fluidic transducers rely on external components such as solenoid valves and tubing
--> How do repetition time and tube length influence the signal?
Ultrasonic measurement technology has become indispensable in NDT. In order to reduce measurement time and extend the application to other materials, contactless ultrasound is the subject of many different research groups. Department 8 has been researching successfully in this field for years. A novel approach is based on so-called fluidic devices. These devices can be used to perform binary logic operations with the help of natural flow instabilities. Hence the abbreviated name, Fluidic (FLUID+LogIC). Only a pressure reservoir of the used fluid is required as energy supply. This enables the production of very robust actuators that generate ultrasonic signals in an extremely energy efficient way.
The presentation includes the research results of the ZIM innovation project OsciCheck. The original idea will be presented and its application on different building materials is validated. Beyond this, the possible application areas are much larger and a detailed outlook is given to discuss the future potential of fluidic ultrasonic actuators.
Development of an Accurate and Robust Air-Coupled Ultrasonic Time-of-Flight Measurement Technique
(2022)
Ultrasonic time-of-flight (ToF) measurements enable the non-destructive characterization of material parameters as well as the reconstruction of scatterers inside a specimen. The time-consuming and potentially damaging procedure of applying a liquid couplant between specimen and transducer can be avoided by using air-coupled ultrasound. However, to obtain accurate ToF results, the waveform and travel time of the acoustic signal through the air, which are influenced by the ambient conditions, need to be considered. The placement of microphones as signal receivers is restricted to locations where they do not affect the sound field. This study presents a novel method for in-air ranging and ToF determination that is non-invasive and robust to changing ambient conditions or waveform variations. The in-air travel time was determined by utilizing the azimuthal directivity of a laser Doppler vibrometer operated in refracto-vibrometry (RV) mode. The time of entry of the acoustic signal was determined using the autocorrelation of the RV signal. The same signal was further used as a reference for determining the ToF through the specimen in transmission mode via cross-correlation. The derived signal processing procedure was verified in experiments on a polyamide specimen. Here, a ranging accuracy of <0.1 mm and a transmission ToF accuracy of 0.3μs were achieved. Thus, the proposed method enables fast and accurate non-invasive ToF measurements that do not require knowledge about transducer characteristics or ambient conditions.
This data article presents characteristic acoustic and flow data of a fluidic ultrasonic transducer as well as acoustic data of a commercial piezoelectric ultrasonic transducer used in non-destructive testing for civil engineering. The flow data has been acquired using hot-wire anemometry and a Pitot tube. The three-dimensional acoustic data of both devices has been acquired using a calibrated microphone. The distribution of characteristic acoustic properties of both transducers are extracted and given in addition to the raw data. The data presented in the article will be a valuable source for reference and validation, both for developing fluidic and alternate ultrasound generation technologies. Furthermore, they will give additional insight into the acoustic-flow interaction phenomena of high speed switching devices. This article is accompanying the paper Experimental Analysis of the Acoustic Field of an Ultrasonic Pulse Induced by a Fluidic Switch (Bühling et al., 2021) published in The Journal of the Acoustical Society of America, where the data is interpreted in detail and the rationale for characteristic sound properties of the fluidic transducer are given.
AbstractAir‐coupled ultrasonic testing (ACU) is a pioneering technique in non‐destructive testing (NDT). While contact testing and fluid immersion testing are standard methods in many applications, the adoption of ACU is progressing slowly, especially in the low ultrasonic frequency range. A main reason for this development is the difficulty of generating high amplitude ultrasonic bursts with equipment that is robust enough to be applied outside a laboratory environment. This paper presents the fluidic ultrasonic transducer as a solution to this challenge. This novel aeroacoustic source uses the flow instability of a sonic jet in a bistable fluidic switch to generate ultrasonic bursts up to 60 kHz with a mean peak pressure of 320 Pa. The robust design allows operation in adverse environments, independent of the operating fluid. Non‐contact through‐transmission experiments are conducted on four materials and compared with the results of conventional transducers. For the first time, it is shown that the novel fluidic ultrasonic transducer provides a suitable acoustic signal for NDT tasks and has potential of furthering the implementation of ACU in industrial applications.This article is protected by copyright. All rights reserved