Forschungsdatensätze der BAM
Filtern
Erscheinungsjahr
Dokumenttyp
- Forschungsdatensatz (139)
Referierte Publikation
- nein (139)
Schlagworte
- SEM (23)
- XPS (23)
- HAXPES (22)
- Automation (17)
- NanoSolveIT (15)
- SAXS (15)
- X-ray scattering (15)
- Bonding analysis (14)
- Computational Chemistry (10)
- Database (10)
- MOUSE (10)
- Materials Informatics (10)
- Nanoparticles (9)
- Software (7)
- Mechanical testing (5)
- Additive manufacturing (4)
- Ontology (4)
- R package (4)
- Sample holder (4)
- Shear modulus (4)
- Ultrasound (4)
- Young's modulus (4)
- Aging (3)
- Aluminium alloy (3)
- Artificial neural networks (3)
- BAM reference data (3)
- Concrete (3)
- Creep (3)
- Data processing (3)
- Elastic modulus (3)
- High-throughput computations (3)
- Mass Spectrometry (3)
- Microdosimetry (3)
- Nanomaterials (3)
- Nondestructive testing (3)
- Python (3)
- Reference data (3)
- SANS (3)
- Scattering pattern analysis (3)
- Simulation (3)
- Titania nanoparticles (3)
- Validation (3)
- X-ray (3)
- Copper alloys (2)
- Data analysis (2)
- Data conversion (2)
- Dataset (2)
- Digitalization (2)
- Dosimetry (2)
- Elastic wave (2)
- Fe3O4 (2)
- Fenics (2)
- Framework (2)
- G5P (2)
- Geant4 (2)
- HDF5 (2)
- Interlaboratory comparison (2)
- MCS (2)
- Measurement data conversion (2)
- Monte-Carlo simulation (2)
- NXsas (2)
- Nanocomposite (2)
- NeXus (2)
- Neutron (2)
- Non-destructive testing (2)
- Online NMR spectroscopy (2)
- Particle scattering (2)
- Phonons (2)
- Process industry (2)
- Pulse echo method (2)
- Real-time process monitoring (2)
- Reference material (2)
- Scanning electron microscopy (2)
- Small angle scattering (2)
- Stress relaxation (2)
- Surface area (2)
- Synthetic Aperture Focusing Technique (2)
- TOPAS (2)
- TOPAS-nBio (2)
- Tensile test (2)
- Two-photon polymerization (2)
- XRD (2)
- 3D Fourier Transform (1)
- 3D printing (1)
- 60-230V (1)
- 7790634 (1)
- AIF (1)
- AISI 316L (1)
- ANFO (1)
- Acoustic-flow interaction (1)
- Additive Manufacturing (1)
- Adsorption (1)
- Air-coupled ultrasound (1)
- Aktivkohle (1)
- Al2CuMg (1)
- AlOOH (1)
- Alkali activated concrete (1)
- Alkyls (1)
- Analyses (1)
- Analysis (1)
- Analysis approach (1)
- Anhydrite (1)
- Antiaromaticity (1)
- Antibody (1)
- Arbitrary shapes (1)
- Argon (1)
- Aromatic hydrocarbons (1)
- Au Nanoparticles (1)
- AuNP (1)
- Automated image analysis (1)
- Automated synthesis (1)
- Benchmarking (1)
- Biofilms (1)
- Boehmite (1)
- Bonding Analysis (1)
- Brinell hardness (1)
- Building Floors (1)
- CONSENS (1)
- Calcium sulfate (1)
- Calibration structure (1)
- Cancer therapy (1)
- Ce0.1Zr0.9O2 nanoparticles (1)
- Ce0.25Zr0.75O2 nanoparticles (1)
- Ce0.5Zr0.5O2 nanoparticles (1)
- Ce0.75Zr0.25O2 nanoparticles (1)
- Ce0.9Zr0.1O2 (1)
- CeO2 (1)
- CeO2 nanoparticles (1)
- CeO2/Co3O4 (1)
- Cell (1)
- Cement (1)
- Ceramic microprinting (1)
- Ceria (1)
- Certified reference material (1)
- Channel access (1)
- Charpy test (1)
- Co0.75Fe2.25O4 nanoparticles (1)
- Co1.5Fe1.5O4 nanoparticles (1)
- Co2.25Fe0.75O4 nanoparticles (1)
- Co3O4 nanoparticles (1)
- Coffee (1)
- Columnar ionic liquid crystals (1)
- Command line (1)
- Command-line interface (1)
- Compressive Concrete Strength (1)
- Compressive concrete strength (1)
- Computational Materials Science (1)
- Concrete modelling (1)
- Continuous Manufacturing (1)
- Conventional method (1)
- Covalent Organic Frameworks (1)
- Crack growth (1)
- Creep-fatigue (1)
- DFT (1)
- DNA-Binding protein (1)
- Data (1)
- Data Interoperability (1)
- Data Management (1)
- Data Structures (1)
- Data fitting (1)
- Data format (1)
- Data management (1)
- Data set (1)
- Dataset merging (1)
- Datasets (1)
- Density functional theory (1)
- Digital representation (1)
- Dwell-Fatigue (1)
- EBSD (1)
- EDS (1)
- EN AW 2618A a (1)
- EN AW-2618A (1)
- EPICS (1)
- Ectoine (1)
- Elastic microstructure (1)
- Electric Safety Interlock (1)
- Electrochemical Degradation (1)
- Electron energy (1)
- Electron microscopy (1)
- Elemental composition (1)
- Energy distribution (1)
- Energy-dispersive X-ray fluorescence spectrometers (1)
- Environmental Stress Cracking (1)
- Ermüdung (1)
- Espressokanne (1)
- Exchange interaction (1)
- Experimental data (1)
- Explosives (1)
- FAIR (1)
- FAIR data (1)
- FEM (1)
- FFT (1)
- FNCT (1)
- Fe2O3 nanoparticles (1)
- Feedstock powder (1)
- Ferromagnetism (1)
- Flow-through (1)
- Fluidics (1)
- Flux Analysis (1)
- Full-Notch Creep Test (1)
- Full-notch creep test (1)
- Fungus (1)
- GPR (1)
- GV5 (1)
- Geant4-DNA (1)
- Geological material (1)
- Gold (1)
- Graphene related 2D materials (1)
- Graphs (1)
- Hard-energy X-ray photoelectron spectroscopy (1)
- Hardness test (1)
- Heated (1)
- High Resolution (1)
- Human factor (1)
- Human influence (1)
- ICP-MS (1)
- IN718 (1)
- Image averaging (1)
- Image segmentation (1)
- Images (1)
- Imaging techniques (1)
- Impact-Echo (1)
- Impact-echo (1)
- Indium Tin Oxide (1)
- Instrument control (1)
- Instrumentation (1)
- Kikuchi pattern (1)
- Knowledge Representation (1)
- LLG (1)
- Laboratory (1)
- Laboratory automation (1)
- Landau Lifshitz equation (1)
- Laser writing (1)
- Liquid crystals (1)
- Localized model order reduction (1)
- Low-cycle fatigue. (1)
- MALDI (1)
- Magnetic moment (1)
- Magnetic nanoparticles (1)
- Magnetism (1)
- Magnetron Sputtering (1)
- Mass Isotopomer Distribution (1)
- Mass spectrometry (1)
- Material Moisture (1)
- Materials informatics (1)
- Measurement methodology (1)
- Measurement uncertainty (1)
- Medium Entropy Alloys (1)
- Membrane polymers (1)
- Mesocrystal (1)
- Metabolomics (1)
- Metallic glasses (1)
- Methodology (1)
- Micorscopic dose-damage relation (1)
- Micromagnetism (1)
- Microporous polymers (1)
- Microprinting (1)
- Microstructural characterization (1)
- Microstructure analysis (1)
- Mitochondria (1)
- Moka Pot (1)
- Monte carlo (1)
- Monte-Carlo simulations (1)
- Motor controller (1)
- Multi-photon light structuring (1)
- Multi-scale measurements (1)
- Multiscale methods (1)
- Multivariate Data Analysis (1)
- NMR spectroscopy (1)
- Nano powder (1)
- Nanoindentation (1)
- Nanoparticle (1)
- Near Infrared Spectroscopy (1)
- Neural networks (1)
- Neutron scattering (1)
- Nickel-base alloy (1)
- Nimonic 75 (1)
- Nitrogen (1)
- Nuclear Magnetic Resonance (1)
- Nucleus (1)
- OOMMF (1)
- Object oriented micromagnetic framework (1)
- Olive oil (1)
- Olivine (1)
- On-Site (1)
- Open Data (1)
- Open data (1)
- Open science (1)
- Optical constants (1)
- PDF (1)
- PE-HD (1)
- PMD Core Ontology (1)
- Particle size distribution (1)
- Photon counting detectors (1)
- Physisorption (1)
- Piezoelectric transducer (1)
- Plattform MaterialDigital (1)
- Polydispersity (1)
- Polyethylene (1)
- Polymer nanocomposite (1)
- Polymers (1)
- Porosity (1)
- Powder Characterization (1)
- Powder X-ray diffraction (1)
- Process Analytical Technology (1)
- Proper Generalized Decomposition (1)
- Proper orthogonal (1)
- Protein (1)
- Proteins (1)
- Pulse-echo technique (1)
- Quantitative estimation (1)
- Radiation protection (1)
- Radiation therapy (1)
- Radii distribution (1)
- Radiography (1)
- Rebound Hammer (1)
- Rebound number (1)
- Reconstruction algorithm (1)
- Reduced Order Model (1)
- Reference material BCR-425 (1)
- Reference structure (1)
- Refractory high entropy alloys (1)
- Reproducibility, scientific workflow (1)
- Research data management (1)
- Round Robin (1)
- Round robin (1)
- S-phase (1)
- S1-ZGV mode (1)
- S355 steel sheet (1)
- SAXS/WAXS (1)
- STL file input (1)
- Sample cell (1)
- Saxs (1)
- Scattering (1)
- Scattering pattern (1)
- Scattering pattern simulation (1)
- Scientific software (1)
- Screening method (1)
- Semantic Web Technologies (1)
- Semantic Web technologies (1)
- Sequential learning (1)
- Shiny-App (1)
- Silver (1)
- Small-angle Scattering (1)
- Small-angle scattering (1)
- Spectra annotation (1)
- Spectral response (1)
- Spectroscopic Ellipsometry (1)
- Spectroscopic techniques (1)
- Stochastic Landau Lifshitz Gilbert equation (1)
- Strength (1)
- Strontium isotope ratio (1)
- Structure prediction (1)
- Structured Data (1)
- Systems architecture (1)
- TED-GC/MS (1)
- TEM (1)
- Targeted nanoparticle (1)
- Temperature (1)
- Temperature scaling (1)
- Tempered martensite-ferritic steel (1)
- Tensile Test (1)
- Tensile testing (1)
- Test structure (1)
- Thermal conductivity (1)
- Thermoanalytik (1)
- Thetaevolve (1)
- Ti-6Al-4V (1)
- TiO2 D540 nanoparticles (1)
- TiO2 PVP (1)
- TiO2 nanoparticles (1)
- Tool comparison (1)
- Traceability derivation (1)
- Transmission electron microscopy (1)
- Transparency (1)
- USAXS (1)
- Ultrasonic Pulse Velocity (1)
- Ultrasonic guided waves (1)
- Ultrasonic pulse velocity (1)
- VSSA (1)
- Vacuum compatible (1)
- Value assignment (1)
- Variational multiscale method (1)
- Volume specific surface area (1)
- WAXS (1)
- Waxs (1)
- Weathering (1)
- WelDX (1)
- Welding (1)
- Workflow management (1)
- X-Ray (1)
- X-Ray Computed Tomography (1)
- X-ray diffraction (1)
- X-ray photoelectron spectroscopy (1)
- X-ray reflectivity (1)
- X-ray science (1)
- XCT (1)
- Yttria-stabilized zirconia (1)
- Zenodo (1)
- ZnO (1)
- ZnO nanoparticles (1)
- ZrO2 nanoparticles (1)
- extension (1)
- module (1)
- stl code (1)
- technical drawings (1)
- total scattering (1)
- ultra-small-angle X-ray scattering (1)
Organisationseinheit der BAM
- 6 Materialchemie (81)
- 6.1 Oberflächen- und Dünnschichtanalyse (29)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (28)
- 5 Werkstofftechnik (21)
- 6.0 Abteilungsleitung und andere (19)
- 8 Zerstörungsfreie Prüfung (18)
- 5.2 Metallische Hochtemperaturwerkstoffe (16)
- VP Vizepräsident (12)
- VP.1 eScience (12)
- 1 Analytische Chemie; Referenzmaterialien (11)
Electric Safety Interlock
(2023)
This interlock is designed to prevent electrical shock from high voltage (>60V) equipment.
While the general safety interlock can be generically applied, this particular example employs an external vacuum-activated switch. It is for safeguarding human operations inside a vacuum sample chamber while the chamber doors are open. The circuit is closed (output is active) when a sufficient level of vacuum is reached, i.e. when all accessible openings are necessarily closed.
The initial application is to interrupt power to a 220V, 250W heating cartridge (itself mounted inside a small sample holder with potentially exposed contacts) when the sample chamber is open.
The external circuit can be modified to use different interlock mechanisms as needed. Note that the external interlock circuit is only a single circuit (with two signal lines) and thus is not protected against external shorts.
To accomodate a range of safety interlocks, the 4-pin M12 connector is wired as follows: Pin 1 (Brown): +24V for power supply, max current 0.6A Pin 2 (White): Safety interlock system signal 1 (0 or 24V) Pin 3 (Blue) : Safety interlock system signal 2 (0 or 24V) Pin 4 (Black): 0V for power supply
The safety is interlocked (output active) when both signal pins are set high (24V), with sufficient current to activate the two relays. Pin 1 and 4 can be used to power safety hardware (such as light curtains or proximity detectors) with 24VDC up to a current of 0.6A. A larger power supply can be installed when higher currents are needed, while staying within the current limits imposed by the wiring cross-section.
Despite the advances in hardware and software techniques, standard numerical methods fail in providing real-time simulations, especially for complex processes such as additive manufacturing applications. A real-time simulation enables process control through the combination of process monitoring and automated feedback, which increases the flexibil- ity and quality of a process. Typically, before producing a whole additive manufacturing structure, a simplified experiment in form of a bead-on- plate experiment is performed to get a first insight into the process and to set parameters suitably. In this work, a reduced order model for the transient thermal problem of the bead-on-plate weld simulation is devel- oped, allowing an efficient model calibration and control of the process. The proposed approach applies the proper generalized decomposition (PGD) method, a popular model order reduction technique, to decrease the computational effort of each model evaluation required multiple times in parameter estimation, control and optimization. The welding torch is modeled by a moving heat source, which leads to difficulties separating space and time, a key ingredient in PGD simulations. A novel approach for separating space and time is applied and extended to 3D problems allowing the derivation of an efficient separated representation of the tem- perature. The results are verified against a standard finite element model showing excellent agreement. The reduced order model is also leveraged in a Bayesian model parameter estimation setup, speeding up calibrations and ultimately leading to an optimized real-time simulation approach for welding experiment using synthetic as well as real measurement data.
X-ray scattering and sorption data associated with the publication "Antiaromatic Covalent Organic Frameworks Based on Dibenzopentalenes". X-ray scattering data is provided for COF and POP materials, including data from stability tests, as three-column ascii files with columns q (nm-1), I (m-1) and uncertainty on I, as well as being provided in 2θ.
The dataset contains experimental mechanical data from complex service-like creep-fatigue experiments performed isothermally at 620 °C and a low strain amplitude of 0.2 % on tempered martensite-ferritic grade P92 steel. The data sets in text file format provide cyclic deformation (min. and max. stresses) and the total (hysteresis) data of all recorded fatigue cycles for three different creep-fatigue experiments: 1) a standard relaxation fatigue (RF) test with symmetrical dwell times of three minutes introduced at minimum and maximum strain, 2) a fully strain-controlled service-like relaxation (SLR) test combining these three-minute peak strain dwells with a 30-minute dwell in between at zero strain, and 3) a partly stress-controlled service-like creep (SLC) test combining the three-minute peak strain dwells with 30-minute dwells at constant stress.
Further information on data and data acquisition, analysis, and experimental details are given in “Experimental Data from Service-Like Creep-Fatigue Experiments on Grade P92 Steel”, submitted to Data in Brief. Additional analyses of these datasets, as well as experimental findings and discussions are presented in “Creep-Fatigue of P92 in Service-Like Tests with Combined Stress- and Strain-Controlled Dwell Times”, submitted to International Journal of Fatigue.
The fourth dataset dedicated to the Open Guided Waves platform presented in this work aims at a carbon fiber composite plate with an additional omega stringer at constant temperature conditions. The dataset provides full ultrasonic guided wavefields.
A chirp signal in the frequency range 20-500 kHz and Hann windowed tone-burst signal with 5 cycles and carrier frequencies of 16.5 kHz, 50 kHz, 100 kHz, 200 kHz and 300kHz are used to excite the wave. The piezoceramic actuator used for this purpose is attached to the center of the stringer side surface of the core plate.
Three scenarios are provided with this setup: (1) wavefield measurements without damage, (2) wavefield measurements with a local stringer debond and (3) wavefield measurements with a large stringer debond. The defects were caused by impacts performed from the backside of the plate. As result, the stringer feet debonds locally which was verified with conventional ultrasound measurements.
The dataset can be used for benchmarking purposes of various signal processing methods for damage imaging.
The detailed description of the dataset is published in Data in Brief Journal.
The dataset provided in this repository comprises data obtained from a series of full-notch creep tests (FNCT) performed on selected high-density polyethylene (PE-HD) materials (for further details, see section 1 Materials in this document) in accordance with the corresponding standard ISO 16770.
The FNCT is one of the mechanical testing procedures used to characterize polymer materials with respect to their environmental stress cracking (ESC) behavior. It is widely applied for PE-HD materials, that are predominantly used for pipe and container applications. It is based on the determination of the time to failure for a test specimen under constant mechanical load in a well-defined and temperature controlled liquid environment. The test device used here also allows for continuous monitoring of applied force, specimen elongation and temperature.
Dataset and Jupyter worksheet interpreting the (results from) small- and wide-angle scattering data from a series of boehmite/epoxy nanocomposites. Accompanies the publication "Competition of nanoparticle-induced mobilization and immobilization effects on segmental dynamics of an epoxy-based nanocomposite", by Paulina Szymoniak, Brian R. Pauw, Xintong Qu, and Andreas Schönhals.
Datasets are in three-column ascii (processed and azimuthally averaged data) from a Xenocs NanoInXider SW instrument. Monte-Carlo analyses were performed using McSAS 1.3.1, other analyses are in the Python 3.7 worksheet. Graphics and result tables are output by the worksheet.
This dataset accompanies the following publication, first published in Scientific Reports (www.nature.com/articles/s41598-021-84287-6):
B. Ruehle, J. Krumrey, V.-D. Hodoroaba, Scientific Reports, Workflow towards Automated Segmentation of Agglomerated, Non-Spherical Particles from Electron Microscopy Images using Artificial Neural Networks, DOI: 10.1038/s41598-021-84287-6
It contains electron microscopy micrographs of TiO2 particles, the corresponding segmentation masks, and their classifications into different categories depending on their visibility/occlusion. Please refer to the publication and its supporting information for more details on the acquisition and contents of the dataset, as well as the GitHub repository at https://github.com/BAMresearch/automatic-sem-image-segmentation
A tool for merging and/or rebinning single or multiple datasets to achieve a lower point density with best possible statistics. highly scriptable, CLI, no GUI
Version 0.1: works but could do with a cleanup. Weighting by uncertainty currently always on, but should be optional for use as an azimuthal or radial averager
This contribution contains the raw data used to compare experimental results with thermodynamic calculations using the CALPHAD method, which is related to the research article “The AlMo0.5NbTa0.5TiZr refractory high entropy superalloy: experimental findings and comparison with calculations using the CALPHAD method” [1] , and therefore this article can be used as a basis for interpreting the data contained therein. The AlMo0.5NbTa0.5TiZr refractory superalloy was characterized in the cast and annealed condition (1400 °C for 24 h) in order to measure grain size and to identify and measure the size and area fraction of the phases present. The raw data of this article include X-ray diffraction (XRD) measurements, microstructural characterization by scanning and transmission electron microscopy (SEM and TEM), and elemental analysis by energy dispersive X-ray spectroscopy (EDX). XRD includes the determination of phases and the lattice parameters (A2, B2, and hexagonal structure). Microstructural analysis by scanning and transmission electron microscopy includes (1) identification of composition, size, and volume fraction of the present phases and (2) determination of grain size. Based on these experimental data, it is possible to identify similarities and discrepancies with the data calculated using the CALPHAD method for the alloy under study in Ref. [1] , which provides the basis for better and more efficient development of reliable databases.
This dataset represents the electronic supplementary material (ESM) of the publication entitled "Characterisation of conventional 87Sr/86Sr isotope ratios in cement, limestone and slate reference materials based on an interlaboratory comparison study", which is published in Geostandards and Geoanalytical Research under the DOI: 10.1111/GGR.12517. It consists of four files. 'ESM_Data.xlsx' contains all reported data of the participants, a description of the applied analytical procedures, basic calculations, the consensus values, and part of the uncertainty assessment. 'ESM_Figure-S1' displays a schematic on how measurements, sequences and replicates are treated for the uncertainty calculation carried out by PTB. 'ESM_Technical-protocol.pdf' is the technical protocol of the interlaboratory comparison, which has been provided to all participants together with the samples and which contains bedside others the definition of the measurand and guidelines for data assessment and calculations. 'ESM_Reporting-template.xlsx' is the Excel template which has been submitted to all participants for reporting their results within the interlaboratory comparison. Excel files with names of the the structure 'GeoReM_Material_Sr8786_Date.xlsx' represent the Rcon(87Sr/86Sr) data for a specific reference material downloaded from GeoReM at the specified date, e.g. 'GeoReM_IAPSO_Sr8786_20221115.xlsx' contains all Rcon(87Sr/86Sr) data for the IAPSO seawater standard listed in GeoReM until 15 November 2022.
This file contains all the data used for the figures shown in the Dissertation of Ruben Gerrits with the title "An experimental study of fungal olivine weathering".
In this study, the weathering-affecting, rock-inhabiting fungus, Knufia petricola A95 and the Fe-bearing olivine (Fe0.2Mg1.8SiO4) were selected to investigate fungi-induced effects on mineral dissolution. The availability of a melanin-deficient mutant (ΔKppks) of K. petricola A95, that produced more extracellular polymeric substances (EPS) than the wild type (WT), enabled comparative studies of the role of melanin and EPS in weathering processes.
Data for the publication "The role of extracellular polymeric substances of fungal biofilms in mineral attachment and weathering" (https://doi.org/10.1038/s41529-022-00253-1). It includes:
- The Summary of the EPS concentration, EPS sugar components and EPS linkages.
- The Summary of the XPS analysis of freeze-dried biofilm samples of all strains.
- The Summary of the pH, Mg, SI and Fe concentration, biomass and olivine dissolution rate for each time point of all dissolution experiments.
Data file (RData) containing measurement data recorded during the production process of the Certified Reference Material BAM-A001 containing Polycyclic Aromatic Hydrocarbons (PAH) in olive oil. The data can be most conveniently openend using the Shiny-App eCerto which is accessible at https://www.bam.de/eCerto.
Metabolomics, the analysis of potentially all small molecules within a biological system, has become a valuable tool for biomarker identification and the elucidation of biological processes. While metabolites are often present in complex mixtures at extremely different concentrations, the dynamic range of available analytical methods to capture this variance is generally limited. Here, we show that gas chromatography coupled to atmospheric pressure chemical ionization mass spectrometry (GC-APCI-MS), a state of the art analytical technology applied in metabolomics analyses, shows an average linear range (LR) of 2.39 orders of magnitude for a set of 62 metabolites from a representative compound mixture. We further developed a computational tool to extend this dynamic range on average by more than 1 order of magnitude, demonstrated with a dilution series of the compound mixture, using robust and automatic reconstruction of intensity values exceeding the detection limit. The tool is freely available as an R package (CorrectOverloadedPeaks) from CRAN (https://cran.r-project.org/) and can be incorporated in a metabolomics data processing pipeline facilitating large screening assays.
The investigation of metabolic fluxes and metabolite distributions within cells by means of tracer molecules is a valuable tool to unravel the complexity of biological systems. Technological advances in mass spectrometry (MS) technology such as atmospheric pressure chemical ionization (APCI) coupled with high resolution (HR), not only allows for highly sensitive analyses but also broadens the usefulness of tracer-based experiments, as interesting signals can be annotated de novo when not yet present in a compound library. However, several effects in the APCI ion source, i.e., fragmentation and rearrangement, lead to superimposed mass isotopologue distributions (MID) within the mass spectra, which need to be corrected during data evaluation as they will impair enrichment calculation otherwise. Here, we present and evaluate a novel software tool to automatically perform such corrections. We discuss the different effects, explain the implemented algorithm, and show its application on several experimental datasets. This adjustable tool is available as an R package from CRAN.
This dataset is a complete set of raw, processed and analyzed data, complete with Jupiter notebooks, associated with the manuscript mentioned in the title.
In the manuscript, we provide a "systems architecture"-like overview and detailed discussions of the methodological and instrumental components that, together, comprise the "MOUSE" project (Methodology Optimization for Ultrafine Structure Exploration). Through this project, we aim to provide a comprehensive methodology for obtaining the highest quality X-ray scattering information (at small and wide angles) from measurements on materials science samples.
Models for TOPAS/Geant4 to estimate the microscopic dose received by biomolecules during bioSAXS experiments.
The C++ classes in this repository extend the functionality of the TOPAS (http://www.topasmc.org/) Monte-Carlo program, which is itself a wrapper of the Geant4 MCS Toolkit (http://geant4.org).
Software-driven scientific workflows are often characterized by a complex interplay of various pieces of software executed in a particular order. The output of a computational step may serve as input to a subsequent computation, which requires them to be processed sequentially with a proper mapping of outputs to inputs. Other computations are independent of each other and can be executed in parallel. Thus, one of the main tasks of a workflow tool is a proper and efficient scheduling of the individual processing steps.
Each processing step, just as the workflow itself, typically processes some input and produces output data. Apart from changing the input data to operate on, processing steps can usually be configured by a set of parameters to change their behavior. Moreover, the behavior of a processing step is determined by its source code and/or executable binaries/packages that are called within it. Beyond this, the computation environment not only has a significant influence on its behavior, but is also crucial in order for the processing step to work at all. The environment includes the versions of the interpreters or compilers, as well as all third-party libraries and packages that contribute to the computations carried out in a processing step.
The elastic properties (Young's modulus, shear modulus) of titanium alloy Ti-6Al-4V were investigated between room temperature and 400 °C in an additively manufactured variant (laser-based directed energy deposition with powder as feedstock, DED-LB/M) and from a conventional process route (hot rolled bar). The moduli were determined using the dynamic resonance method. The data set includes information on processing parameters, heat treatments, microstructure, grain size, specimen dimensions and weight, Young’s and shear modulus as well as their measurement uncertainty.
The dataset was generated in an accredited testing lab using calibrated measuring equipment. The calibrations meet the requirements of the test procedure and are metrologically traceable. The dataset was audited as BAM reference data.
The elastic properties (Young's modulus, shear modulus) of Ni-based alloy Inconel IN718 were investigated between room temperature and 800 °C in an additively manufactured variant (laser powder bed fusion, PBF‑LB/M) and from a conventional process route (hot rolled bar). The moduli were determined using the dynamic resonance method. The data set includes information on processing parameters, heat treatments, grain size, specimen dimensions and weight, Young’s and shear modulus as well as their measurement uncertainty.
The dataset was generated in an accredited testing lab using calibrated measuring equipment. The calibrations meet the requirements of the test procedure and are metrologically traceable. The dataset was audited as BAM reference data.
The elastic properties (Young's modulus, shear modulus) of austenitic stainless steel AISI 316L were investigated between room temperature and 900 °C in an additively manufactured variant (laser powder bed fusion, PBF‑LB/M) and from a conventional process route (hot rolled sheet). The moduli were determined using the dynamic resonance method. The data set includes information on processing parameters, heat treatments, grain size, specimen dimensions and weight, Young’s and shear modulus as well as their measurement uncertainty.
The dataset was generated in an accredited testing lab using calibrated measuring equipment. The calibrations meet the requirements of the test procedure and are metrologically traceable. The dataset was audited as BAM reference data.
ABID
(2022)
In order to automate the spectral comparison for larger libraries of antibodies, we developed the online software ABID 2.0. This open-source software determines the number of matching peptides in the fingerprint spectra. We propose that publications and other documents critically relying on monoclonal antibodies with unknown amino acid sequences should include at least one antibody fingerprint. By fingerprinting an antibody in question, its identity can be confirmed by comparison with a library spectrum at any time and context.
This database consists of bonding data computed using Lobster for 1520 solid-state compounds consisting of insulators and semiconductors. The files are named as per ID numbers in the materials project database.
Here we provide the larger computational data JSON files for the rest of the 820 compounds. This file consists of all important LOBSTER computation output files data stored as a dictionary.
This database consists of bonding data computed using Lobster for 1520 solid-state compounds consisting of insulators and semiconductors. It consists of two kinds of json files. Smaller lightweight JSONS consists of summarized bonding information for each of the compounds. The files are named as per ID numbers in the materials project database.
Here we provide also the larger computational data json files for 700 compounds. This files consists of all important LOBSTER computation output files data stored as dictionary.
2PP-TestArtifact
(2023)
This repository contains a test artifact (TA), also called test structure, designed for two-photon polymerization (also known as Direct Laser Writing (DLW) or Two/Multi-photon lithography (2PA/MPA)). Test artifacts can be used to compare structures, to check options used by the slicer, check the state of the 2PP machine itself or to get a construction guidelines for a certain combination of power, velocity and settings.
The associated paper can be found here: https://dx.doi.org/10.1088/1361-6501/acc47a
General ideas behind the test artifact:
1. optimized for 2PP-DLW
2. should be fast and easy to analyse with optical microscopy or 3. scanning electron microscopy without tilt.
3. short time to fabricate
4. include a reasonable amount of different features
5. bulk and small structures on the substrate