Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
- 2019 (209) (entfernen)
Dokumenttyp
- Zeitschriftenartikel (163)
- Beitrag zu einem Tagungsband (40)
- Buchkapitel (3)
- Sonstiges (2)
- Forschungsbericht (1)
Schlagworte
- Fluorescence (8)
- Nanoparticles (6)
- Ultraschall (6)
- Corrosion (5)
- Additive manufacturing (4)
- Flame retardant (4)
- Mechanochemistry (4)
- Sustainability (4)
- Zerstörungsfreie Prüfung (4)
- Additive Fertigung (3)
- Concrete (3)
- Energy label (3)
- IgG (3)
- Nanomaterial (3)
- Quantum yield (3)
- Africa (2)
- Antibody coating (2)
- Artificial neural networks (2)
- Atomic force microscopy (2)
- BODIPY (2)
- Benz[a]anthracene (BaA) (2)
- Benzo[a]pyrene (BaP) (2)
- Biochip (2)
- Bioconjugation (2)
- Biosensor (2)
- Boehmite (2)
- Carbon steel (2)
- Cellulose (2)
- Characterization (2)
- Corrosion Fatigue (2)
- DNA origami (2)
- Discotic Liquid Crystals (2)
- Distributed fiber optic sensing (2)
- Distributed vibration sensing (2)
- Dual sensing (2)
- ELISA (2)
- EPDM (2)
- ESEM (2)
- Electrochemistry (2)
- Embedded sensors (2)
- Energy transfer (2)
- Epoxy (2)
- Ettringite (2)
- Explicit dynamics (2)
- Fatigue (2)
- Fatigue tests (2)
- Fatty acid metabolism (2)
- Ferromagnetism (2)
- Friction (2)
- Gadolinium (2)
- Gas chromatography (GC) (2)
- Geruch (2)
- High Alloyed Steel (2)
- Hyperbranched (2)
- Imaging (2)
- Immunoassay (2)
- Immunocapture (2)
- Immunoglobulins (2)
- Immunoprecipitation (2)
- Immunosensor (2)
- Impact simulation (2)
- In situ (2)
- Indium phosphide (2)
- Interphase (2)
- Isogeometric analysis (2)
- Isotope dilution (ID) (2)
- Lapis lazuli (2)
- Laser beam melting (2)
- Lifetime (2)
- Lipidomic profile (2)
- Liquid chromatography (LC) (2)
- MALDI-TOF MS (2)
- Manuscripts (2)
- Mass spectrometry (MS) (2)
- Materials (2)
- Metabolic stress (2)
- Micro-XRF (2)
- NDT (2)
- Nanostructures (2)
- Normen (2)
- Optical fiber sensor (2)
- PGAA (2)
- PIXE (2)
- Phosphorus (2)
- Pigment analyses (2)
- Pitting (2)
- Polycyclic aromatic hydrocarbon (PAH) (2)
- Polylactide (2)
- Polymers (2)
- Protein A (2)
- Protein G (2)
- Provenance studies (2)
- Proximity-enhanced reaction (2)
- Quantum dots (2)
- Raman spectroscopy (2)
- Reinforced concrete (2)
- SAXS (2)
- Scattering (2)
- Sensitization (2)
- Sensor (2)
- Small-angle scattering (2)
- Standards (2)
- Structural health monitoring (2)
- Surface (2)
- Synthesis (2)
- Technical crack detection (2)
- Thermal anhydrite (2)
- ToF-SIMS (2)
- Toxicity (2)
- Tubular X-joints (2)
- Tumor metabolism (2)
- Ultrasound (2)
- Upconversion nanoparticles (2)
- VOC Emissionen (2)
- Wear (2)
- X-ray diffraction (2)
- 3D Druck (1)
- 3D inspection (1)
- 3D printing (1)
- AISI 304L (1)
- Acoustic-Structure Interaction (1)
- Additives (1)
- Adulteration (1)
- Advanced Materials (1)
- Aerial robot olfaction (1)
- Affinity chromatography (1)
- Affinitätschromatographie (1)
- Affinitätsextraktion (1)
- AgBB Bewertung (1)
- Ageing (1)
- Aggregates (1)
- Agriculture (1)
- Air conditioner (1)
- Air-conditioning (1)
- Air-coupled (1)
- Al/SiO2 composite (1)
- Alexander von Humboldt (1)
- Alkali-activated materials (1)
- Alkali-activated slag (1)
- Alpha (1)
- Altenuene (1)
- Alternaria mycotoxins (1)
- Alumina (1)
- Aluminium (1)
- Aluminum diethylphosphinate (1)
- Aluminum trihydroxide (ATH) (1)
- Amorphous carbon (1)
- Analytical methods (1)
- Analytics (1)
- Anisotropic fiber orientation (1)
- Anobium punctatum (1)
- Anomalous Small Angle X-ray Scattering (1)
- Antibacterial (1)
- Antifouling surface (1)
- Antikörper (1)
- Apis mellifera (1)
- Archaeometry (1)
- Array (1)
- Art restauration (1)
- Artificial neural network (1)
- Automated Modal Analysis for Tracking Structural Change during Construction and Operation Phases (1)
- Automated arc welding (1)
- Autophagy (1)
- BODIPYs (1)
- Bacterial adhesion (1)
- Ball milling (1)
- Bead injections (1)
- Bead-based assay (1)
- Bee diseases (1)
- Bee health (1)
- Benzin (1)
- Beton-Oberflächenschutzsysteme (1)
- Bewertung (1)
- Bias (1)
- Bildqualität (1)
- Binder (1)
- Bioactive glass (1)
- Biodegradable (1)
- Biofilm (1)
- Biological pest control (1)
- Biomarkers (1)
- Biomaterials (1)
- Biopolymer (1)
- Biosilicification (1)
- Blade (1)
- Blended cement (1)
- Bloch wall (1)
- Boden (1)
- Bodenbelag (1)
- Bodenbeläge (1)
- Boehmite nanoparticles (1)
- Borosilikatglas (1)
- Brennfleck (1)
- Brick clay (1)
- Bridge monitoring (1)
- Bridges (1)
- Broadband dielectric microscopy (1)
- Brückenmonitoring (1)
- Building materials (1)
- Bulk temperature (1)
- C-C coupling (1)
- C-OTDR (1)
- CCQM (1)
- CCUS (1)
- CFK (1)
- CO2 (1)
- CO2 separation membranes (1)
- COD-AGE (1)
- COK-12 (1)
- CONSENS (1)
- Calcined clay (1)
- Calcium phosphate (1)
- Calorimetry (1)
- Carbamazepine (1)
- Carbide (1)
- Carbon capture, utilization and storage technology (1)
- Carbon emissions (1)
- Carriers (1)
- Catalyst (1)
- Catalysts (1)
- Categorisation scheme (1)
- Cationic photocuring (1)
- Cell size (1)
- Cement admixtures (1)
- Cement clinker remnants (1)
- Cement hydration (1)
- Ceramic (1)
- Chemometrics (1)
- Chloride extraction (1)
- Chunky graphite (1)
- Civil Engineering (1)
- Civil engineering (1)
- Cleridae (1)
- Click chemistry (1)
- Clones (1)
- Co (1)
- Coating (1)
- Cobaloxime complex (1)
- Cobalt (1)
- Coda wave interferometry (1)
- Coherent optical time domain reflectometry (1)
- Cold to fast neutron testing (1)
- Coleoptera (1)
- Colourants (1)
- Compatibility evaluation (1)
- Competitive Immunoassay (1)
- Components of excitation (1)
- Composite (1)
- Composite material (1)
- Composite-Druckgefäß (1)
- Composites (1)
- Compression set (1)
- Compressive strength (1)
- Computed Tomography (1)
- Computed tomography (1)
- Condensate (1)
- Condition monitoring (1)
- Cone calorimeter (1)
- Conference (1)
- Construction (1)
- Continuous processes (1)
- Coptic (1)
- Coputed tomography (1)
- Core-shell nanoparticles (1)
- Core−shell particles (1)
- Corresponding relative humidity (1)
- Corrosion monitoring (1)
- Corrosion rate (1)
- Cr(III) complex (1)
- Crack detection (1)
- Crack formation (1)
- Crack pattern (1)
- Cracks (1)
- Cross-linking (1)
- Crosslinker (1)
- Crosslinking density (1)
- Crystalline cones (1)
- Crystallization (1)
- Cultural heritage (1)
- Curie temperature (1)
- Cybersecurity Act (1)
- Cybersicherheit (1)
- Cyclic (1)
- Cyclic load (1)
- Cyclic softening (1)
- Cyclization (1)
- Cycloaliphatic epoxy oligosiloxane (1)
- Cytotoxicity (1)
- DFA (1)
- DFG SPP 2005 (1)
- DFT (1)
- DLO (1)
- DMA (1)
- DPA (1)
- DRIFTS (1)
- DTGS (1)
- DVS (1)
- Damage detection (1)
- Dampfdruck (1)
- Damping factor (1)
- Data Fusion (1)
- Dead Sea Scrolls (1)
- Decision support (1)
- Degradation of refrigerants (1)
- Delta value (1)
- Dendritic (1)
- Density Functional Theory (1)
- Deuterium (1)
- Dibenzo[d,f][1,3,2]dioxaphosphepine 6-oxide (1)
- Dielectric breakdown (1)
- Diffraction (1)
- Digitale Radiographie (1)
- Disposal (1)
- Distributed acoustic sensing (1)
- Distributed acoustic sensing (DAS) (1)
- Distributed acoustic sensor (DAS) (1)
- Distributed fiber optic sensors (1)
- Distributed humidity sensing (1)
- Distributed sensing (1)
- Distributed strain sensing (1)
- Distributed temperature gradient sensing (1)
- Distributed vibrations sensing (DVS) (1)
- Domain wall (1)
- Double complex salts (1)
- Drone (1)
- Druckbehältern (1)
- Druckstabilität (1)
- Dual phase steel (1)
- Dye (1)
- Dynamic test method (1)
- EC definition of a nanomaterial (1)
- EC nanomaterial definition (1)
- EC/MS (1)
- EXAFS (1)
- Early oxidation (1)
- Early sulfidation (1)
- Education (1)
- Elastin (1)
- Electric impedance (1)
- Electro-fused zirconia (1)
- Electrochemical characterisation (1)
- Electrochemical impedance spectroscopy (1)
- Electromagnetic stirring (1)
- Electron microscopy (1)
- Electron transfer (1)
- Endurance Limit (1)
- Energetic Materials (1)
- Engineered Barrier System (EBS) (1)
- Epoxies (1)
- Epoxy conversion degree (1)
- Europium (1)
- Exchange interaction (1)
- Exchange length (1)
- Excimers (1)
- Expert system (1)
- FAME (1)
- FPLC (1)
- FSDC (1)
- False Positives (1)
- Faserverbund (1)
- Fe (1)
- Femtosecond laser (1)
- Fenton’s reagent (1)
- Ferritic spheroidal graphite cast iron (1)
- Ferritic steels (1)
- Ferritic–martensitic steel (1)
- Ferumoxytol (1)
- Fiber optic sensor (1)
- Fiber optic sensors (1)
- Fiber optics sensors (1)
- Fiber reinforced polymer (1)
- Fiber structuring (1)
- Fiber-optic sensing (1)
- Fiber-reinforced concrete (1)
- Fiberoptic sensors (1)
- Finite element analysis (1)
- Fire resistance (1)
- Fire test (1)
- Flame retardance (1)
- Flame retardants (1)
- Fluidic oscillator (1)
- Fluidischer Oszillator (1)
- Fluoreszenz (1)
- Fluoroacetic acid (1)
- Foams (1)
- Food (1)
- Food fermentation (1)
- Food safety (1)
- Formation (1)
- Formic Acid (1)
- Frequenzanalyse (1)
- Fs-inscription (1)
- Full Matrix Capture (1)
- Full penetration (1)
- Fully aromatic frameworks (1)
- Fungus (1)
- Funtional Groups (1)
- Galvanic corrosion (1)
- Gamma (1)
- Gas explosion (1)
- Gas sensing (1)
- Gas tomography (1)
- Gasoline (1)
- Genome (1)
- Genotoxicity testing (1)
- Geology (1)
- Geothermal (1)
- Giant magnetoresistance (1)
- Glasmonolith (1)
- Glass fiber reinforced polymers (1)
- Glass scanning (1)
- Glass-fiber-reinforced plastic transport tank (1)
- Graphene (1)
- Graphene Oxide (1)
- Ground water (1)
- Grout (1)
- Grouted connection (1)
- Guided Waves (1)
- Gypsum dehydration (1)
- HNBR (1)
- HPLC (1)
- HTS (1)
- Hapten Immunoassay (1)
- Hard metals (1)
- Hardmetal (1)
- Heat pump (1)
- Heating oil with 10 % FAME (1)
- Herbaspirillum seropedicae (1)
- Herceptin (1)
- High-fired gypsum (1)
- High-fired medieval gypsum mortars (1)
- High-voltage testing (1)
- Hot-electrons (1)
- Humboldt Codices (1)
- Hybrid laser-arc welding (1)
- Hybridoma (1)
- Hydrogel (1)
- Hydrogen (1)
- Hydrolysis (1)
- Hydrothermal fluid (1)
- Icing conditions (1)
- Illite (1)
- Imidazole (1)
- Immunglobulin (1)
- Immunoaffinity extraction (1)
- Impurities (1)
- In-situ testing (1)
- In-vivo (1)
- Inconel 718 (1)
- Incremental lifetime models (1)
- Indenter modulus (1)
- Independent test method (1)
- Infrared nano AFM (1)
- Ink (1)
- Innenraumluftqualtität (1)
- Innovation (1)
- Inspection planning (1)
- Interlaboratory comparison (1)
- Intermodulation (1)
- Intermodulation AFM (1)
- Intermodulation-AFM (1)
- Inverse analysis (1)
- Iron (1)
- Iron oxide (1)
- Isotope ratio (1)
- Isotope-labeled (1)
- Issues (1)
- Kaolinite (1)
- Kinetics (1)
- Klassifizierung (1)
- Konformitätsbewertung (1)
- Korynetes caeruleus (1)
- Künstliche Bewitterung (1)
- LC/HRMS (1)
- LL equation (1)
- LLG (1)
- Lab-on-a-Chip (1)
- Laboratory breeding (1)
- Lache (1)
- Ladder sequencing (1)
- Laminography (1)
- Landau Lifshitz Gilbert equation (1)
- Landau Lifshitz equation (1)
- Lanthanide (1)
- Large-pore (1)
- Laser Powder Bed Fusion (1)
- Laser beam welding (1)
- Laser welding (1)
- Laser-Doppler-Vibrometer (1)
- Laser-induced X-ray emission (1)
- Laser-induced nanostructures (1)
- Laser-induced periodic surface structures (LIPSS) (1)
- Laser-modified surface (1)
- Lattice structure (1)
- Layers (1)
- Leak-tightness (1)
- Lebensdauerversuche (1)
- Life history data (1)
- Lightweight materials (1)
- Local fatigue approaches (1)
- Local fatigue spproaches (1)
- Localised corrosion (1)
- Long term monitoring (1)
- Longst luminescence lifetime (1)
- Low cycle fatigue (1)
- Luftgekoppelt (1)
- Luminescence (1)
- Lysosome (1)
- MALDI (1)
- MOF (1)
- Magnesium (1)
- Magnet coupling (1)
- Magnetic (1)
- Magnetic Nanoparticles (1)
- Magnetic anisotropy (1)
- Magnetic interacion (1)
- Magnetic moment (1)
- Magnetic properties (1)
- Magnetic sensors (1)
- Magnetic thin films (1)
- Magnetization dynamics (1)
- Magnetocaloric effect (1)
- Magnéli phase (1)
- Maritime Atmosphäre (1)
- Maritime atmosphere (1)
- Market surveillance (1)
- Martensite (1)
- Maskinteknik (1)
- Mass spectrometry (1)
- Material moisture (1)
- Measurement campaigns (1)
- Mechanical Engineering (1)
- Mechanical property (1)
- Mechanical strength (1)
- Mechanistic study (1)
- Medical implants (1)
- Mehrfachreflexion (1)
- Melamine cyanurate (1)
- Melamine polyphosphate (1)
- Mesofluidics (1)
- Mesoporous Silica (1)
- Metal carbides (1)
- Metal phosphonates (1)
- Metal-Oxide Gas Sensor Array (1)
- Metal–organic frameworks (1)
- Metathesis (1)
- Method (1)
- Metrology (1)
- Microarray (1)
- Microbeads (1)
- Microcracking (1)
- Microfine Cement (1)
- Micromagnetism (1)
- Mikro-Computertomographie (1)
- Mikroplastik (1)
- Minimum energy performance standards (1)
- Mix-design (1)
- Mixed surface (1)
- Mobile robot olfaction (1)
- Modal Analysis (1)
- Model (1)
- Modified mycotoxins (1)
- Moisture (1)
- Molecular MRI (1)
- Molecular sieves (1)
- Molecule (1)
- Monensin (1)
- Monoclonal Antibodies (1)
- Mortar method (1)
- Mukuru (1)
- Multiple-layered scaffold (1)
- Multiplex (1)
- Multivariate (1)
- Multivariate data analysis (1)
- NIR (1)
- NIR Spectroscopy (1)
- NIR dyes (1)
- NMR (1)
- NMR Spectroscopy (1)
- NMR relaxometry (1)
- Nanaoparticles (1)
- Nanocasting (1)
- Nanocomposite (1)
- Nanocomposites (1)
- Nanoconfinement (1)
- Nanolenses (1)
- Nanomechanical properties (1)
- Nanomechanics (1)
- Nanoparticle dimers (1)
- Nanoporous (1)
- Nanosciences (1)
- Nanostructured material (1)
- Naphthalene (Nap) (1)
- Natural (1)
- Neel wall (1)
- Neutron Imaging (1)
- Ni (1)
- Nickel (1)
- Niobium carbide (1)
- Non-destructiv testing (1)
- Non-invasive analysis (1)
- Nosema ceranae (1)
- OOMMF (1)
- OTDR (1)
- Object oriented micromagnetic framework (1)
- Offshore foundations (1)
- Offshore wind turbines (1)
- Oligonucleotides (1)
- Optical backscatter reflectometry (1)
- Optical frequency-domain reflectometry (1)
- Optical time domain reflectometry (1)
- Organic calibration solution (1)
- Organic contaminants (1)
- Organic–inorganic nanostructures (1)
- Oriented immobilization (1)
- Origami (1)
- Oscillating magnetic field (1)
- Osmia bicornis (1)
- Oxidative metabolism (1)
- Oxygen permability (1)
- Oxygen sensitive (1)
- P92 (1)
- POD (1)
- Parabolic flight (1)
- Paramagnetism (1)
- Passive RFID (1)
- Pathogen (1)
- Pathogen transmission (1)
- Peptide library (1)
- Performance (1)
- Permeability (1)
- Pesticide (1)
- Pflanzenwachstum (1)
- Pharmaceutical (1)
- Phase transition (1)
- Phase-sensitive (1)
- Phased Array (1)
- Phospha-Michael addition (1)
- Phosphinine (1)
- Photocatalytic reduction (1)
- Photochemistry (1)
- Photon counting detector (1)
- Photophysics (1)
- Photostability (1)
- Physical relaxation (1)
- Phytoliths (1)
- Pipeline integrity (1)
- Pitting corrosion (1)
- Plant pathogen (1)
- Plasmonic heating (1)
- Plume (1)
- Polyaniline (1)
- Polycaprolactone (1)
- Polycarbonate (1)
- Polyethylene (1)
- Polyimide-coated optical fibers (1)
- Polyisocyanurate (1)
- Polymerbeschichtungen auf Beton (1)
- Polymere (1)
- Polyphosphoester (1)
- Pore fluids (1)
- Pore size distribution (1)
- Porous building materials (1)
- Porous materials (1)
- Porphyrin (1)
- Portland cement (1)
- Powder X-ray diffraction (1)
- Powder analysis (1)
- Prediction (1)
- Prevention (1)
- Probe (1)
- Properties (1)
- Ptinidae (1)
- Quality assurance (1)
- Quantitative Analysis (1)
- Quantitative moisture measurement (1)
- Quantum dot (1)
- Quellfleckgröße (1)
- RFA (1)
- RFID based sensors (1)
- Radiation protection (1)
- Rainwater (1)
- Raman (1)
- Raman band width (1)
- Raman microscopy (1)
- Raman microspectroscopy (1)
- Raman-spectroscopy (1)
- Rapid mass calorimeter (1)
- Rayleigh scattering (1)
- Re-assessment of exiting bridges (1)
- Real time measurement (1)
- Real use behavior (1)
- Real-time imaging (1)
- Real-time infrared spectroscopy (1)
- Real-time process monitoring (1)
- Real-time quality control (1)
- Refracto-vibrometry (1)
- Refraktovibrometrie (1)
- Regeneration (1)
- Regenerator (1)
- Regulatory identification of nanomaterials (1)
- Relaxation fatigue (1)
- Reliability (1)
- Repair patch (1)
- Research (1)
- Residual stress (1)
- Resistance spot welding (1)
- Restoration and conservation (1)
- Reverse glass painting (1)
- Reverse microemulsion (1)
- Rhizopus and Aspergillus oryzae (1)
- Rice (1)
- Richtcharakteristik (1)
- Risk (1)
- Risk assessment (1)
- Rissbildung in Stahl (1)
- Rosin (1)
- Roughness (1)
- Rubber (1)
- Röntgenröhre (1)
- SDC (1)
- SEM (1)
- SERS (1)
- SHM (1)
- SI Traceability (1)
- SIDA-LC-MS/MS (1)
- Safe by design (1)
- Salicylate (1)
- Salicylic acid (1)
- Salinization (1)
- Salts (1)
- Samarium doped ceria (1)
- Sandwich (1)
- Scaffolds (1)
- Scaled Boundary Finite Element Method (1)
- Scanning electrochemical microscope (SECM) (1)
- Scavenging effect of iron (1)
- Schallemission (1)
- Schallemissionsanalyse (1)
- Schallemissionsprüfung (1)
- Schichtdickenbestimmung (1)
- Schiene (1)
- Schienenprüfung (1)
- Schmiedeteile (1)
- Science (1)
- Sciences (1)
- Scission (1)
- Screed (1)
- Screening (1)
- Screening method (1)
- Seal failure (1)
- Seasonal energy efficiency ratio (1)
- Seasonal performance factor (1)
- Seismic measurement (1)
- Selective Laser Melting (1)
- Sensors (1)
- Shrinkage Reducing Admixture (1)
- Silica (1)
- Silica coating (1)
- Simulation (1)
- Single molecule (1)
- Single-source precursors (1)
- Sintering (1)
- Small angle scattering (1)
- Smart structures (1)
- Soil (1)
- Soil-structure interaction (1)
- Solid state NMR (1)
- Solid state cooling (1)
- Solitary bees (1)
- Sorghum (1)
- Spectral elements (1)
- Spectroscopic imaging (1)
- Spectroscopy (1)
- Spill evaporation (1)
- Spin (1)
- SrTiO3 (1)
- SsNMR (1)
- Stabilization (1)
- Stained glass (1)
- Standardisation (1)
- Standardisierung (1)
- Standardization (1)
- Static load (1)
- Static load monitoring (1)
- Steel (1)
- Steel structures (1)
- Stepwise growth (1)
- Stereocomplex (1)
- Stimulated Brillouin scattering (1)
- Stochastic Landau Lifshitz Gilbert equation (1)
- Stochastic Landau Lifshitz equation (1)
- Stretchable electronics (1)
- Structured light scanning (1)
- Struvite (1)
- Sub-oxide (1)
- Sulfide sensing (1)
- Superparamagnetism (1)
- Superplasticizer (1)
- Supplementary Cementitious Materials (1)
- Surface Chemistry (1)
- Surface chemistry (1)
- Surface relaxivity (1)
- Surface structures (1)
- Surface-enhanced Raman scattering (1)
- Suzuki coupling (1)
- Suzuki-Miyaura coupling (1)
- Synchrotron FTIR (1)
- Synchrotron X-ray diffraction (1)
- Synchrotron computed tomography (1)
- Synchrotron x-ray refraction radiography (SXRR) (1)
- Synergy (1)
- Synthetic Aperture Focusing Technique (1)
- T-SEM (1)
- TDLAS (1)
- TFA (1)
- THz-TDS (1)
- TW-COTDR (1)
- Tape casting (1)
- Target (1)
- Temeprature scaling (1)
- Temperature (1)
- Temperature effects (1)
- Temple Scroll (1)
- Test strips (1)
- Teststreifen (1)
- Thermal expansion (1)
- Thermoelectrics (1)
- Thermografie (1)
- Thermoplastic polyurethane (1)
- Thermoplastics (1)
- Thick materials (1)
- Thick shells (1)
- Thin film systems (1)
- Thin magnetic films (1)
- Ti-6Al-4V (1)
- Titan-Halterung (1)
- Tomographie, (1)
- Tomography of wood samples (1)
- Total Focusing Methode (1)
- Train-induced ground vibration (1)
- Transformation product (1)
- Transformation products (1)
- Trastuzumab (1)
- Tribology (1)
- Trilobite compound eyes (1)
- Triplet-triplet annihilation (1)
- Tumble dryer (1)
- UV Vis (1)
- Ultrashort laser material interaction (1)
- Ultrashort laser pulses (1)
- Upconverstion (1)
- Urban planning (1)
- Urbanisation (1)
- VIS- Spektroskopie (1)
- Validation trial (1)
- Value of action analysis (1)
- Variable frequency drive (1)
- Varroa destructor (1)
- Vehicle-track-soil interaction (1)
- Verdampfung (1)
- Verdunstung (1)
- Versalzung (1)
- Veterinary drugs (1)
- Vibration (1)
- Virulence (1)
- Vorlaufkeile (1)
- Water (1)
- Water layer thickness (1)
- Water transport (1)
- Wavenumber integrals (1)
- Wellenprüfung (1)
- Wheelset accelerations (1)
- Wild bees (1)
- Wind Turbines (1)
- Wind energy (1)
- Wind turbine (1)
- Wind turbine blades (1)
- Windgeschwindigkeit (1)
- Wirbelstrom (1)
- Wirbelstromprüfung (1)
- Wood protection (1)
- Work function (1)
- Writing materials (1)
- X-ray Photoelectron Spectroscopy (1)
- X-ray absorption Fine Spectroscopy (1)
- X-ray and electron diffraction (1)
- X-ray computed tomography (CT) (1)
- X-ray computed tomography (XCT) (1)
- X-ray reflectivity (1)
- XPS (1)
- XRD (1)
- XRF (1)
- Yb(III) complex (1)
- Yerba mate tea (1)
- Zearalenone sulfate (1)
- Zellulose (1)
- ZfP (1)
- Zuverlässigkeit (1)
- a-zearalenol (1)
- biokompatibel (1)
- gesintert (1)
- mortar method (1)
- qPCR (1)
- spectral elements (1)
- temeprature dependent exchange length (1)
- thermografisches Verfahren (1)
- µ-gravity (1)
- γ-H2AX assay (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (51)
- 8 Zerstörungsfreie Prüfung (51)
- 6 Materialchemie (37)
- 7 Bauwerkssicherheit (35)
- 4 Material und Umwelt (18)
- 5 Werkstofftechnik (16)
- 6.3 Strukturanalytik (13)
- 8.5 Röntgenbildgebung (12)
- 9 Komponentensicherheit (12)
- 1.2 Biophotonik (11)
Thermal decomposition of [Co(NH₃)₆][Fe(C₂O₄)₃]∙3H₂O in argon atmosphere, at a low heating rate (3°/min), and in large amounts of the initial complex (~0.1 mole), has been studied. It was possible to distinguish four decomposition steps upon heating: In the temperature range of 50⁻100 °C-the loss of crystal water; 100⁻190 °C-stability region of dehydrated complex; 230⁻270 °C-the range of stability of intermediate phase with the formula CoFe(NH₃)₂(C₂O₄)₂; 270⁻350 °C-thermal decomposition of the intermediate with the formation of metallic products and further air oxidation with the formation of Co1.5Fe1.5O₄. Catalytic properties of thermolysis products were tested in the decomposition reaction of H₂O₂ (inactive), oxidation of acetone (average activity), and decomposition of ammonium perchlorate (highly active).
Due to their excellent creep resistance and good oxidation resistance, 9–12% Cr ferritic–martensitic stainless steels are widely used as high temperature construction materials in power plants. However, the mutual combination of different loadings (e.g., creep and fatigue), due to a “flexible” operation of power plants, may seriously reduce the lifetimes of the respective components. In the present study, low cycle fatigue (LCF) and relaxation fatigue (RF) tests performed on grade P92 helped to understand the behavior of ferritic–martensitic steels under a combined loading. The softening and lifetime behavior strongly depend on the temperature and total strain range. Especially at small strain amplitudes, the lifetime is seriously reduced when adding a hold time which indicates the importance of considering technically relevant small strains.
Das Ziel dieses Kapitels besteht darin, die Rolle von Konformitätsbewertung für die Erhöhung der Cybersicherheit von Produkten, Dienstleistungen und Prozessen zu betrachten. Dazu wird der Begriff Cybersicherheit beleuchtet sowie ausgewählte Cybersicherheitsnormen kurz vorgestellt. Im Folgenden wird der regulative europäische Rahmen für die Konformitätsbewertung aus ordnungspolitischer Sicht sowie der aktuelle Verordnungsentwurf zum Cybersecurity Act dargestellt und kritsch beleuchtet.
To study the effects of condensed acid liquid, hereafter referred to as condensate, on the CO2 transport pipeline steels, gas mixtures containing a varying concentration of H2O, O2, NO2, and SO2, were proposed and resulted in the condensate containing H2SO4 and HNO3 with the pH ranging from 0.5 to 2.5. By exposing the pipeline steel to the synthetic condensate with different concentration of acidic components, the corrosion kinetic is significantly changed. Reaction kinetic was studied using electrochemical methods coupled with water analysis and compared with surface analysis (scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and X-ray diffractometry (XRD)) of corroded coupons. The results showed that, although the condensation of NO2 in the form of HNO3 causes faster general corrosion rate, it is the condensation of SO2 in the form of H2SO4 or the combination of SO2 and NO2 that may cause much more severe problems in the form of localized and pitting corrosions. The resulting corrosion forms were depended on the chemical nature of acids and their concentration at the same investigated pH. The effects of changing CO2 flow rate and renewing condensate on pitting corrosion were further studied.
We report on the ferromagnetism of Sn1-xZnxO2 (x < 0.1) hierarchical nanostructures with various morphologies synthesized by a solvothermal route. A room temperature ferromagnetic and paramagnetic response was observed for all compositions, with a maximum in ferromagnetism for x = 0.04. The ferromagnetic behaviour was found to correlate with the presence of zinc on substitutional Sn sites and with a low oxygen vacancy concentration in the samples. The morphology of the nanostructures varied with zinc concentration. The strongest ferromagnetic response was observed in nanostructures with well-formed shapes, having nanoneedles on their surfaces. These nanoneedles consist of (110) and (101) planes, which are understood to be important in stabilizing the ferromagnetic defects. At higher zinc concentration the nanostructures become eroded and agglomerated, a phenomenon accompanied with a strong decrease in their ferromagnetic response. The observed trends are explained in the light of recent computational studies that discuss the relative stability of ferromagnetic defects on various surfaces and the role of oxygen vacancies in degrading ferromagnetism via an increase in free electron concentration.
The thermoelectric properties of Sr1-xBixTiO3-δ (0 ≤ x ≤ 0.07) have been investigated. Dense ceramics of Sr1-xBixTiO3-δ and Sr0.95TiO3-δ have been prepared by solid-state reaction and conventional sintering in air followed by annealing in a reducing atmosphere. XRD and SEM analyses show that the rutile TiO2 in Sr0.95TiO3 formed after sintering becomes Magnéli phase of TinO2n-1 after annealing. Moreover, Bi resolves from Sr1-xBixTiO3 after annealing, resulting in the formation of Sr1-xBixTiO3-δ/Bi/TinO2n-1 composites. With increasing Bi content in Sr1-xBixTiO3-δ, the electrical conductivity increases while the absolute values of the Seebeck coefficient decrease as a result of increasing carrier concentration. The thermal conductivity of SrTiO3-δ is reduced by doping Bi up to x = 0.07. Highest ZT ~ 0.13 is obtained in Sr0.93Bi0.07TiO3-δ at 1000 K.
Commercial bead-based assays are commonly built upon polystyrene particles. The polymeric carrier can be encoded with organic dyes and has ideal material properties for cytometric applications such as low density and high refractive index. However, functional groups are conventionally integrated during polymerization and subsequent modification is limited to the reactivity of those groups. Additionally, polystyrene as the core material leads to many hydrophobic areas still being present on the beads’ surfaces even after functionalization, Rendering the particles prone to nonspecific adsorption during an application. The latter calls for several washing steps and the use of additives in (bio)analytical assays. In this contribution, we show how these limitations can be overcome by using monodisperse polystyrene (PS) core/silica (SiO2) shell particles (SiO2@PS). Two different hydrophobic BODIPY (boron−dipyrromethene) dyes were encapsulated inside a poly(vinylpyrrolidone) (PVP) -stabilized polystyrene core in different concentrations to create 5-plex arrays in two separate detection channels of a cytometer. A subsequent modification of the silica shell with an equimolar APTES/PEGS (aminopropyltriethoxysilane/polyethylene glycol silane) blend added multifunctional properties to the hybrid core/Shell microparticles in a single step: APTES provides amino groups for the attachment of a caffeine derivative (as a hapten) to create antigen-coupled microspheres; the PEG moiety effectively suppresses nonspecific binding of antibodies, endowing the surface with antifouling properties. The particles were applied in a competitive fluorescence immunoassay in suspension, and a highly selective wash-free assay for the detection of caffeine in beverages was developed as a proof of concept.
Real-time observation of high- temperature gas corrosion in dry and wet SO2-containing atmosphere
(2019)
Sulfur and water have a fundamental impact on the corrosion rate and potential failure of materials. It is therefore necessary to understand the mechanisms, rates, and potential means of transport, as well as the reactions of these elements with an alloy. This paper investigates the effect of water vapor in the initial stages of SO2 corrosion of an Fe-9Cr-0.5Mn model alloy at 650°C in situ under laboratory conditions using energy-dispersive x-ray diffraction analysis. Two separate experiments were run, one with a 99.5% Ar + 0.5% SO2 atmosphere and one with a 69.5% Ar + 0.5% SO2 + 30% H2O atmosphere. With a wet atmosphere, the alloy formed a scale with decreasing oxygen content towards the scale–alloy interface. Sulfides were identified above and below a (Fe, Cr)3O4 layer in the inner corrosion zone. In contrast to this, the overall scale growth was slower in a dry SO2 atmosphere.
The multicomponent flame retardant system of melamine polyphosphate (MPP), melamine cyanurate (MC) and aluminum diethylphosphinate (AlPi) is proposed and investigated for thermoplastic polyurethane (TPU). The synergy between those additives and the resulting superior fire performance are discussed. Systematically varied sets of flame retarded TPU with various MPP/MC/AlPi ratios were investigated in terms of fire behavior, pyrolysis products and mechanical properties. The total amount of the additives was always 30 wt.-%. Further, the influence of various AlPi concentrations was investigated. The optimal MPP:MC ratio was determined while keeping the amount of AlPi constant. The combination of 8 wt.-% MPP, 12 wt.-% MC and 10 wt.-% is proposed as the most promising halogen free flame retardant formulation for TPU, because it yielded a reduction in PHRR from 2660 kW/m2 (TPU) to 452 kW/m2 and enabled V-0 classification in the UL 94 test. Combinations of MPP and MC as well a high concentration of AlPi are beneficial for the mechanical properties e.g. tensile strength and elongation at break of the formulations and could be a strong competitor to commercial flame retarded TPUs.
Natural keratin fibres derived from Mexican tannery waste and coconut fibres from coconut processing waste were used as fillers in commercially available, biodegradable thermoplastic starch-polyester blend to obtain sustainable biocomposites. The morphology, rheological and mechanical properties as well as pyrolysis, flammability and forced flaming combustion behaviour of those biocomposites were investigated. In order to open up new application areas for these kinds of biocomposites, ammonium polyphosphate (APP) was added as a flame retardant. Extensive flammability and cone calorimeter studies revealed a good flame retardance effect with natural fibres alone and improved effectiveness with the addition of APP. In fact, it was shown that replacing 20 of 30 wt. % of APP with keratin fibres achieved the same effectiveness. In the case of coconut fibres, a synergistic effect led to an even lower heat release rate
and total heat evolved due to reinforced char residue. This was confirmed via scanning electron microscopy of the char structure. All in all, these results constitute a good approach towards sustainable and biodegradable fibre reinforced biocomposites with improved flame retardant properties.
The assessment of Coda Wave Interferometry (CWI) and Distributed Fiber Optics Sensing (DFOS) techniques for the detection of damages in a laboratory size reinforced concrete beam is presented in this paper. The sensitivity of these two novel techniques to micro cracks is discussed and compared to standard traditional sensors. Moreover, the capacity of a DFOS technique to localize cracks and quantify crack openings is also assessed. The results show that the implementation of CWI and DFOS techniques allow the detection of early subtle changes in reinforced concrete structures until crack formation. With their ability to quantify the crack opening, following early detection and localization, DFOS techniques can achieve more effective monitoring of reinforced concrete structures. Contrary to discrete sensors, CWI and DFOS techniques cover larger areas and thus provide more efficient infrastructures asset management and maintenance operations throughout the lifetime of the structure.
Carbon dots have attracted much attention due to their unique optical, chemical and electronic properties enabling a wide range of applications. The properties of carbon dots can be effectively adjusted through modifying their chemical composition. However, a major challenge remains in understanding the core and surface contributions to optical and electronic transitions. Here, three blue luminescent carbon dots with carboxyl, amino and hydroxyl groups were comprehensively characterized by UV-vis absorption and emission spectroscopy, synchrotron-based X-ray spectroscopy, and infrared spectroscopy. The influence of the surface functionality on their fluorescence was probed by pH-dependent photoluminescence measurements. Moreover, the hydrogen bonding interactions between water and the surface groups of carbon dots were characterized by infrared spectroscopy. Our results show that both core and surface electronic states of blue luminescent carbon dots contribute to electronic acceptor levels while the chemical nature of the surface groups determines the hydrogen bonding behavior of the carbon dots. This comprehensive spectroscopic study demonstrates that the surface chemistry has a profound influence on the electronic configuration and surface–water interaction of carbon dots, thus affecting their photoluminescence properties.
Photon upconversion nanomaterials have a wide range of applications, including biosensing and deep-tissue imaging. Their typically very weak and narrow absorption bands together with their size dependent luminescence efficiency can limit their application potential. This has been addressed by increasingly sophisticated core-shell particle architectures including the sensitization with organic dyes that strongly absorb in the near infrared (NIR). In this work, we present a simple water-dispersible micellar system that features energy transfer from the novel NIR excitable dye, 1859 SL with a high molar absorption coefficient and a moderate fluorescence quantum yield to oleate-capped NaYF4:20%Yb(III), 2%Er(III) upconversion nanoparticles (UCNP) upon 808 nm excitation. The micelles were formed using the surfactants Pluronic F-127 and Tween 80 to produce a hydrophilic dye-UCNP system. Successful energy transfer from the dye to the UCNP could be confirmed by emission measurements that revealed the occurrence of upconversion emission upon excitation at 808 nm and an enhancement of the green Er(III) emission compared to direct Er(III) excitation at 808 nm.
In this paper we report on the characterization by X-ray computed tomography of calcium phosphate (CaP) and polycaprolactone (PCL) coatings on Ti-6Al-4V alloy scaffolds used as a material for medical implants. The cylindrical scaffold has greater porosity of the inner part than the external part, thus, mimicking trabecular and cortical bone, respectively. The prismatic scaffolds have uniform porosity. Surface of the scaffolds was modified with calcium phosphate (CaP) and polycaprolactone (PCL) by dip-coating to improve biocompatibility and mechanical properties. Computed tomography performed with X-ray and synchrotron radiation revealed the defects of structure and morphology of CaP and PCL coatings showing small platelet-like and spider-web-like structures, respectively.
Worldwide there is a variety of regulatory provisions addressing nanomaterials. The identification as nanomaterial in a regulatory context often has the consequence that specific legal rules apply. In identifying nanomaterials, and to find out whether nanomaterial-specific provisions apply, the external size of particles is globally used as a criterion. For legal certainty, its assessment for regulatory purposes should be based on measurements and methods that are robust, fit for the purpose and ready to be accepted by different stakeholders and authorities. This should help to assure the safety of nanomaterials and at the same time facilitate their international trading. Therefore, we propose a categorisation scheme which is driven by the capabilities of common characterisation techniques for particle size measurement. Categorising materials according to this scheme takes into account the particle properties that are most important for a determination of their size. The categorisation is exemplified for the specific particle number based size metric of the European Commission's recommendation on the definition of nanomaterial, but it is applicable to other metrics as well. Matching the performance profiles of the measurement techniques with the material property profiles (i) allows selecting the most appropriate size determination technique for every type of material considered, (ii) enables proper identification of nanomaterials, and (iii) has the potential to be accepted by regulators, industry and consumers alike. Having such a scheme in place would facilitate the regulatory assessment of nanomaterials in regional legislation as well as in international relations between different regulatory regions assuring the safe trade of nanomaterials.
Extraction, chromatographic separation, and quantification of low-concentration organic compounds in complex matrices are core challenges for reference material producers and providers of calibration services. Evidence of successful participation in formal, relevant international comparisons is needed to document measurement capability claims made by national metrology institutes (NMIs) and designated institutes (DIs). To enable NMIs and DIs to update or establish their claims, in 2014 the Organic Analysis Working Group (OAWG) initiated CCQM-K95.1 "Low-Polarity Analytes in a Botanical Matrix: Polycyclic Aromatic Hydrocarbons (PAHs) in Tea". This was a follow-on comparison from CCQM-K95 which was completed in 2014.
The polycyclic aromatic hydrocarbons (PAHs) benz[a]anthracene (BaA) and benzo[a]pyrene (BaP) are considered priority pollutants by U.S. Environmental Protection Agency and are regulated contaminants in food, pose chromatographic separation challenges, and for which exist well-characterized measurement procedures and standard materials. BaA and BaP in a smoked tea were therefore selected as representative target measurands for CCQM-K95.1. Ten NMIs participated in CCQM-K95.1. The consensus summary mass fractions for the two PAHs are in the range of (50 to 70) ng/g with relative standard deviations of (6 to 10) %.
Successful participation in CCQM K95.1 demonstrates the following measurement capabilities in determining mass fraction of organic compounds, with molar mass of 100 g/mol to 500 g/mol and having polarity pKow −2, in a botanical matrix ranging in mass fraction from 10 ng/g to 1000 ng/g: (1) value assignment of primary reference standards (if in-house purity assessment carried out), (2) value assignment of single and/or multi-component organic solutions, (3) extraction of analytes of interest from the matrix, (4) cleanup and separation of analytes of interest from interfering matrix or extract components, and (5) separation and quantification using gas chromatography or liquid chromatography.
Solutions of organic analytes of known mass fraction are typically used to calibrate the measurement processes used to determine these compounds in matrix samples. Appropriate value assignments and uncertainty calculations for calibration solutions are critical for accurate measurements. Evidence of successful participation in formal, relevant international comparisons is needed to document measurement capability claims (CMCs) made by national metrology institutes (NMIs) and designated institutes (DIs). To enable NMIs and DIs to update or establish their claims, in 2015 the Organic Analysis Working Group (OAWG) sponsored CCQM-K131 "Low-Polarity Analytes in a Multicomponent Organic Solution: Polycyclic Aromatic Hydrocarbons (PAHs) in Acetonitrile".
Polycyclic aromatic hydrocarbons (PAHs) result from combustion sources and are ubiquitous in environmental samples. The PAH congeners, benz[a]anthracene (BaA), benzo[a]pyrene (BaP), and naphthalene (Nap) were selected as the target analytes for CCQM-K131. These targets span the volatility range of PAHs found in environmental samples and include potentially problematic chromatographic separations. Nineteen NMIs participated in CCQM-K131. The consensus summary mass fractions for the three PAHs are in the range of (5 to 25) μg/g with relative standard deviations of (2.5 to 3.5) %.
Successful participation in CCQM-K131 demonstrates the following measurement capabilities in determining mass fraction of organic compounds of moderate to insignificant volatility, molar mass of 100 g/mol up to 500 g/mol, and polarity pKow < −2 in a multicomponent organic solution ranging in mass fraction from 100 ng/g to 100 μg/g: (1) value assignment of primary reference standards (if in-house purity assessment carried out), (2) value assignment of single and/or multi-component organic solutions, and (3) separation and quantification using gas chromatography or liquid chromatography.
Recent recommendations by the Food and Drug Administration1 and the European Medicines Agency2 are to limit the clinical use of linear gadolinium-based contrast agents (GBCAs) due to convincing evidence of deposition in tissues. Macrocyclic GBCA continued to be considered safe, provided that patients have normal renal function. To date, given the low sensitivity of conventional MRI, there has been a debate about the signal increase following the injections of a macrocyclic GBCA.