Wissenschaftliche Artikel der BAM
Filtern
Erscheinungsjahr
- 2013 (34) (entfernen)
Dokumenttyp
- Beitrag zu einem Tagungsband (18)
- Zeitschriftenartikel (15)
- Buchkapitel (1)
Schlagworte
- Thermografie (3)
- Risse (2)
- 13CrMoV9-10 (1)
- Aktive Thermografie (1)
- Algal toxins (1)
- Analytic signal (1)
- Anatoxin-a (1)
- Anatoxin-a(s) (1)
- Anisotropie (1)
- Artificial potential field (1)
Quantifying degradation of collagen in ancient manuscripts: the case of the Dead Sea Temple Scroll
(2013)
Since their discovery in the late 1940s, the Dead Sea Scrolls, some 900 ancient Jewish texts, have never stopped attracting the attention of scholars and the broad public alike, because they were created towards the end of the Second Temple period and the 'time of Christ'. Most of the work on them has been dedicated to the information contained in the scrolls' text, leaving physical aspects of the writing materials unexamined. They are, however, crucial for both historical insight and preservation of the scrolls. Although scientific analysis requires handling, it is essential to establish the state of degradation of these valued documents. Polarized Raman Spectroscopy (PRS) is a powerful tool for obtaining information on both the composition and the level of disorder of molecular units. In this study, we developed a non-invasive and non-destructive methodology that allows a quantification of the disorder (that can be related to the degradation) of protein molecular units in collagen fibers. Not restricted to collagen, this method can be applied also to other protein-based fibrous materials such as ancient silk, wool or hair. We used PRS to quantify the degradation of the collagen fibers in a number of fragments of the Temple Scroll (11Q19a). We found that collagen fibers degrade heterogeneously, with the ones on the surface more degraded than those in the core.
Die Synthetic Aperture Focusing Technique (SAFT) ist ein Verfahren zur Verarbeitung von HF-Bildern, die an unterschiedlichen Prüfkopfpositionen aufgenommen wurden. Es wird in der zerstörungsfreien Werkstoffprüfung genutzt, um eine Abbildung von Materialfehlern innerhalb des Gebietes zu erstellen, auf das die Rekonstruktion angewandt wird. Die nach Abschluss der SAFT-Rekonstruktion zusammengestellten Informationen über Reflektoren liegen zunächst nach wie vor in Form von HF-Daten vor. Die Interpretierbarkeit der SAFT-Bilder ist im Allgemeinen davon abhängig, wie diese Daten vor der endgültigen Darstellung aufbereitet werden. Die Bildung der Amplitudeneinhüllenden aus dem zugehörigen analytischen Signal stellt eine Möglichkeit einer solchen Aufbereitung nach Anwendung des SAFT-Algorithmus dar. Sie ist jedoch nur im eindimensionalen Fall eindeutig definiert. In diesem Beitrag wird das Konzept der analytischen Signale mit single-orthant-Spektren aufgegriffen, um eine Detektion der Einhüllenden an mehrdimensionalen HF-Daten durchzuführen. Dabei wird über die Betragsquadrate aller möglichen nach dieser Definition zu bildenden analytischen Signale gemittelt. Es wird gezeigt, dass die Anwendung des beschriebenen Verfahrens einem Separationsansatz entspricht. Außerdem wird eine Möglichkeit aufgezeigt die Gültigkeit dieses Ansatzes anhand der totalen und partiellen Hilberttransformationen des Signals im konkreten Fall zu überprüfen. Die Ergebnisse dieser Methode zur Verbesserung von SAFT Bildern werden unter Verwendung synthetischer und experimenteller Daten an rekonstruierten Abbildungen verschiedener Reflektorarten beispielhaft dargestellt.
In welding experiments conducted on heavy wall pipes, the penetration mode (full or partial penetration) occurred to be a significant factor influencing appearance of solidification cracks. To explain the observed phenomena and support further optimization of manufacturing processes, a computational model was developed, which used a sophisticated strategy to model the material. High stresses emerged in the models in regions which showed cracking during experiments. In partial penetration welding, they were caused by the prevention of weld shrinkage due to the cold and strong material below the joint. Another identified factor having an influence on high stress localization is bulging of the weld.
Das Monitoring von Bauteilen bei Ermüdungsbelastung mit Hilfe der Schallemission liefert eine große Anzahl an Schallemissionsdaten und –parametern. Um diese in einen Zusammenhang mit dem Schadenszustand des Bauteils zu bringen ist es sinnvoll, einen Bezug zu bekannten bruchmechanischen Kenngrößen herzustellen. Dies wird in dieser Arbeit anhand von Ermüdungsversuchen an Platten aus dem Feinkornstahl P460NL1 versucht. Schallemissionssignale aus Ermüdungsrissen mit und ohne Korrosionseinfluss werden analysiert und mit bekannten bruchmechanischen Kenngrößen wie der Risswachstumsrate und dem Spannungsintensitätsfaktor verglichen.
A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap300® (a multi-bed tube using Carbopack C®, Carbopack B® and Carbosive SIII®) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber
Algal blooms are a frequent phenomenon in nearly all kinds of fresh water. Global warming and eutrophication by waste water, air pollution and fertilizers seem to lead to an increased frequency of occurrence. Many cyanobacteria produce hazardous and quite persistent toxins, which can contaminate the respective water bodies. This may limit the use of the raw water for many purposes. The purification of the contaminated water might be quite costly, which makes a continuous and large scale treatment economically unfeasible in many cases. Due to the obvious risks of algal toxins, an online or mobile detection method would be highly desirable. Several biosensor systems have been presented in the literature for this purpose. In this review, their mode of operation, performance and general suitability for the intended purpose will be described and critically discussed. Finally, an outlook on current developments and future prospects will be given.
Luminescence techniques are among the most widely used detection methods in the life and material sciences. At the core of these methods is an ever-increasing variety of fluorescent reporters (i.e., simple dyes, fluorescent labels, probes, sensors and switches) from different fluorophore classes ranging from small organic dyes and metal ion complexes, quantum dots and upconversion nanocrystals to differently sized fluorophore-doped or fluorophore-labeled polymeric particles. A key parameter for fluorophore comparison is the fluorescence quantum yield (Φf), which is the direct measure for the efficiency of the conversion of absorbed light into emitted light. In this protocol, we describe procedures for relative and absolute determinations of Φf values of fluorophores in transparent solution using optical methods, and we address typical sources of uncertainty and fluorophore class-specific challenges. For relative determinations of Φf, the sample is analyzed using a conventional fluorescence spectrometer. For absolute determinations of Φf, a calibrated stand-alone integrating sphere setup is used. To reduce standard-related uncertainties for relative measurements, we introduce a series of eight candidate quantum yield standards for the wavelength region of ~350950 nm, which we have assessed with commercial and custom-designed instrumentation. With these protocols and standards, uncertainties of 5–10% can be achieved within 2 h.
Für die optische Erwärmung von Prüfteiloberflächen sind Blitz- und Halogenlampen Stand der Technik. Der Vorteil dieser Wärmequellen liegt in ihren relativ geringen Anschaffungskosten bei gleichzeitig hohen Leistungsdichten am Prüfobjekt. Nachteilig ist bei den Halogenlampen die Limitierung der möglichen Modulationsffequenz auf ca. 1 Hz für die Anwendung dieser Quelle in der Lockin-Thermografie. Blitzlampen bieten für gewöhnlich nur eine feste Blitzdauer bei einer geringen Taktrate. Beide Anregungsquellen müssen in Reflexionsanordnung mit Filtern betrieben werden um die entstehende thermische Eigenstrahlung als Störquelle zu eliminieren. Wir stellen Untersuchungen an Hochleistungs-LEDs für den Einsatz in der aktiven Thermografie vor. Diese Lichtquellen werden durch die rasante Entwicklung der möglichen Leistungsdichten nun auch für die thermografische ZfP interessant. Sie zeigen ähnlich dem Laser eine schmale und auf den Werkstoff abstimmbare spektrale Verteilung der Strahlungsleistung bei moderaten Kosten. Die zugrunde liegende Elektrolumineszenz generiert kaum Wärmestrahlung und ermöglicht dadurch die Prüfung während des Erwärmungsvorganges ohne größeren Aufwand. Modulationsfrequenzen über 100 Hz mit thermischen Eindringtiefen < 1 mm sind möglich. Dadurch qualifizieren sich die LEDs zur Anwendung in der Lockin-Thermografie von Metallen und zur oberflächennahen Prüfung von Schichtsystemen. Durch die fast verzögerungsffeie Reaktion der LED auf das steuernde Signal sind nahezu beliebige zeitliche Anregungsformen möglich. Mit solch flexiblen Anregungsformen ließen sich bereits bei den photothermischen Verfahren erfolgreich höhere Tiefenreichweiten und -auflösungen gegenüber den klassischen Methoden der monofrequenten Lockin - und energiereichen Kurzimpuls-Anregung erzielen. Untersuchungen dieser Möglichkeiten im praktischen Einsatz der HochleistungsLEDs werden vorgestellt und mit herkömmlichen Lichtquellen verglichen.
Odour measurements become increasingly important in view of the assessment of indoor air quality and the emissions of building products. Hence they need to be implemented into evaluation schemes such as the AgBB scheme. While there are already standards like DIN ISO 16000-28 and VDI 4302 Part 1 specifying the procedure of odour measurements using a comparison scale, no final validation of the method has been carried out so far. Therefore, a round robin test was conducted in 2012 with 12 participating laboratories that mainly consisted of the following two parts: 1) testing of the available comparison scales with respect to their operational performance and 2) execution of an odour assessment of an acrylic sealant using emission test chambers. Part one included the measurement of the air flow rates and the provided concentrations of the reference substance (acetone). Part two was conducted to test the performance of the laboratories and the applicability of DIN ISO 16000-28 and supplementary VDI 4302 Part 1 by assessing the perceived intensity and the hedonic tone of the air samples. Moreover, samples for VOC analysis were taken from the air in the emission test chamber on the 7th day of testing to allow for quality control. Resulting from this round robin test main deficits were detected and suggestions for the improvement of the odour measurement procedure were made.