Präsentation
Filtern
Erscheinungsjahr
- 2017 (23) (entfernen)
Dokumenttyp
- Vortrag (12)
- Posterpräsentation (11)
Sprache
- Englisch (23)
Referierte Publikation
- nein (23)
Schlagworte
- Nanoparticles (17)
- SEM/EDX (6)
- Nanomaterial classification (5)
- TiO2 (5)
- XPS (5)
- Electrospray deposition (4)
- SEM (4)
- Electron microscopy (3)
- Nanomaterial (3)
- Particle sizing techniques (3)
- Perovskite (3)
- TEM (3)
- ToF-SIMS (3)
- Auger Electron Spectroscopy (2)
- Auger electron spectroscopy (2)
- BET (2)
- EDX (2)
- Fluorine (2)
- Functionalization (2)
- Inter-laboratory comparison (2)
- Nanoplatelets (2)
- Solar cells (2)
- Titania (2)
- Agglomeration (1)
- Bipyramidal TiO2 nanoparticles (1)
- Characterization techniques (1)
- EC definition of a nanomaterial (1)
- EPMA (1)
- EU definition of a nanomaterial (1)
- Electron micrsocopy (1)
- ISO/TC 229 (1)
- Layer analysis (1)
- Layer analytics (1)
- Measurement (1)
- Metrology (1)
- Nanomaterial classfication (1)
- Nanoparticle size distribution (1)
- Number-weighted median size (1)
- Particle size analysis (1)
- Particle size and shape distribution (1)
- Porous layers (1)
- Powder (1)
- Sample preparation (1)
- Shape (1)
- Shape-enegineered nanoparticles (1)
- Size (1)
- Size and shape distribution (1)
- Standardization (1)
- Substrates (1)
- TEM grid (1)
- TEM grids (1)
- TKD (1)
- Thin film analysis (1)
- Thin films (1)
- Traceability (1)
- VAMAS inter-laboratory comparison (1)
- VSSA (1)
- Volume specific surface area (VSSA) (1)
- k-values (1)
Eingeladener Vortrag
- nein (12)
The motivation of this work is to produce thin films perovskite solar cells with constant high light conversion efficiency over time. Loss of efficiency may be caused by structural and/or chemical alterations of the complex layered system. As these changes might take place either in the bulk and/or on the surface of the stratified material, analytical tools addressing both key issues are selected and combined. SEM/EDS combined with XPS were chosen as appropriate methodical approach to characterise perovskite laboratory cells in depth and complementary on top, before and after light exposure. The layered perovskite system investigated here is based on glass covered with fluorine doped tin oxide (FTO), followed by three porous thin films of TiO2, ZrO2 and a thick monolithic carbon. The TiO2 film is subdivided into a dense layer covered by a porous one constituted of nanoparticles with a truncated bipyramidal shape. This layered system serves as the matrix for the perovskite. After infiltration of perovskite solution and annealing, EDS
spectral maps on cross-sections of the specimen have been measured. The distribution of relevant
elements – Si, Sn, Ti, Zr and C – correlates conclusively with layers visible in the acquired SEM images. Lead and iodine are distributed throughout the porous layers C, ZrO2 and TiO2. Specimens were exposed to ambient daylight for 7 weeks. In a SEM micrograph taken of the cross-section of a sample after illumination, the glass substrate and all layers FTO, TiO2, ZrO2 as well as C are clearly identified. EDS data have been acquired under the same measurement conditions as before the illumination. It was found that several weeks of ambient daylight did not change significantly the qualitative elemental composition of lead and iodine throughout the solar cell system. It was confirmed with EDS that nanoparticles identified in high-resolution SEM micrographs contain mainly Pb and I, indicating these to be the perovskite
crystals. However, a time-dependent compositional and chemical altering was observed with XPS for the near-surface region of the outermost ~10 nm after 2 months of illumination.
Although there are many experimental techniques for measuring particle sizes and size distributions, electron microscopy (EM) is still considered as the gold standard in this field, especially when it comes to particle sizes in the nanorange (1 nm – 100 nm). Furthermore, high-resolution X-ray spectroscopy (EDS) can be applied to individual nanoparticles. To be able to extract accurate information from the EM micrographs and EDS elemental maps that are representative for the material under investigation, one needs to assure the representativity of the particles as sampled on the substrate and their homogeneous spatial distribution, to avoid operator bias when selecting the imaged area. Furthermore, agglomeration should be avoided as far as possible. Several sample preparation techniques exist since a long time, the most common way being suspending the particles in a liquid and depositing them on the grid. However, this procedure includes the drying of larger solvent amounts on the substrate itself, which can affect the spatial distribution of the deposited particles. One possibility to overcome this problem is the use of an electrospray system, where the suspension of particles is sprayed onto the substrate in charged droplets that are so small that they either dry off on the substrate immediately without affecting the position of particles, or even already during their flight time to the substrate. No dedicated commercial instruments are available for the preparation of TEM grids yet, only electrostatic deposition of aerosols on TEM grids has been reported so far. To test the prototype and assess its performance, several materials have been sprayed onto TEM grids and the resulting particle distributions were compared to more traditional sample preparation strategies like the “drop on grid” method. Operation parameters such as the sample flow-rate, capillary – substrate distance, electric field strength and sampling period length have been optimised. It was found that the particles deposited by electrospray generally show a much more homogeneous spatial distribution on the substrate and a substantial increase of the number of single particles, which are much better suited to an automatic image evaluation procedure than the agglomerated particles observed otherwise. The applicability of the technique to a broad range of materials is demonstrated by various examples, but also the influence of the substrate, the choice of the particular TEM grid, on the obtained spatial particle distribution is assessed.
The overall objective of project Improved traceability chain of nanoparticle size measurements is to improve the traceability chain for nanoparticle size measurements. The main impact will be achieved by manifold contributions to standard documents for CEN/TC 352 “Nanotechnologies”, which directly addresses the research needs of CEN, CENELEC and ETSI mandated by EC to develop standards for methods and reference materials to accurately measure the size and size distribution of nanoparticles. This will take place in collaboration with ISO/TC229 ‘Nanotechnologies’, ISO/TC24/SC4 ‘Particle characterization’ and ISO/TC201 ‘Surface analysis’/ SC9 ‘Scanning probe microscopy’.
The presentation goes into the characterization of TiO2 engineered nanoparticles within EU/FP7 SETNanoMetro Project and the nanomaterial classification according to the EC definition tested within EU/FP7 NanoDefine Project. Further, ISO/TC 229/JWG 2 activities related on ISO standards in development and inter-laboratory comparisons on measurement of nanoparticle size and shape distribution by SEM and TEM are discussed.
The capability of currently available particle sizing techniques for reliable classification of materials that potentially fall under the EU Definition of a nanomaterial is discussed. A systematic quantitative evaluation of the sizing techniques is presented together with representative case studies of analysis of industrially relevant materials.
Recommendations on the most appropriate and efficient use of techniques for different types of material are given.
The large European nanometrology Project NanoDefine is presented briefly with respect to the challenges of measurement of particle size distribution for complex nanoparticulate materials.
The methods chosen for a tiered approach for the classification of a nanomaterial are discussed with regard to their peformance. Representative resuls on real life, complex shaped nanoparticulate materials are shown.
The recently initiated VAMAS inter-laboratory comparisons to determine the reproducibility necessary for international standardisation have been also presented.
First results of an inter-laboratory comparsion launched in the frame of ISO/TC 229 'Nanotechnologies' / JWG 2 'Measurement and Characterization' are presented and the further data treatment discussed.
Feret min, Feret and Aspect Ratio of bipyramidal TiO2 nanoparticles as determined according to the measurememnt protocol distributed by BAM are compared for all 17 participants for the first time. The inclusion of the case study into the ongoing ISO/TC 229/JWG 2 project on Measurement of size and shape distribution of nanoparticles by TEM is discussed.
A short overview of thin film analysis by SEM/EDX is presented. Relevant steps such as optimization of instrumnetal parameters, extraction of net peak areas, use of standards, calculation of k-values and quantification with the dedicated thin film analysis software (Stratagem) are explained. Examples of different layered aystems are given together with validation of the results.
The press conference on the results of the European Project FP7 constitutes a dissemination event dedicated to the production and characterization of "Shape-engineered TiO2 nanoparticles for metrology of functional properties: setting design rules from material synthesis to nanostructured devices" with the main large-scale applications in the three reference sectors: energy, health and environment.
At the Final Outreach Event of the European FP7 NanoDefine project the results achieved during 4 years of intensive research and development work (2013-2017) with relevant stakeholders and wider community, and their practical implications and impact are presented and discussed. The newly developed particle-size related measurement tools and their practical suitability and applicability to classify materials, formulations and products according to the EC recommendation on the definition of a nanomaterial (2011/696/EU) are demonstrated.