Datei im Netzwerk der BAM verfügbar ("Closed Access")
Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (75)
- Vortrag (29)
- Posterpräsentation (4)
- Beitrag zu einem Tagungsband (3)
- Sonstiges (1)
Schlagworte
- Immunoassay (31)
- ELISA (24)
- Biosensoren (14)
- Antikörper (9)
- Biosensor (9)
- Abwasser (8)
- Carbamazepine (8)
- Biomarkers (7)
- Wastewater (7)
- Antibody (6)
Organisationseinheit der BAM
- 1.8 Umweltanalytik (58)
- 1 Analytische Chemie; Referenzmaterialien (56)
- 1.9 Chemische und optische Sensorik (5)
- 6 Materialchemie (4)
- P Präsident (4)
- P.0 Präsident und andere (4)
- 6.1 Oberflächen- und Dünnschichtanalyse (3)
- 1.5 Proteinanalytik (2)
- 1.1 Anorganische Spurenanalytik (1)
- 6.3 Strukturanalytik (1)
Paper des Monats
- ja (1)
Eingeladener Vortrag
- nein (29)
Der Vortrag beschreibt den Stand der Arbeiten an der BAM, Fachbereich Umweltanalytik zur Entwicklung von Sensoren für die Wasseranalytik. Er stellt die bisherigen Arbeiten da, die ausgehend von ELISAs, zunehmend portable Plattformen wie FPIA und LFIA umfassen. Beas-based Formate werden von mikrotiterplatten-basierten Techniken auf mikrofluidische Lab-on-Chip-Systeme übertragen, die bei geeigneter Miniaturisierung und Automatisierung als Sensorsysteme angesehen werden können. Der Vortrag endet mit einem Blick auf ein laufendes Monitoring-Projekt von anthropogenen Markern in Abwasser und charakterisiert die Treiber, die die Entwicklung von Sensoren für die Wasseranalytik in den letzten Jahren vorantreiben.
Analytische Methoden für die Quantifizierung von Mikroschadstoffen (Synonym für Spurenstoffe) und Pathogenen im Wasser sind eine Grundvoraussetzung für die Umsetzung des Ziels Nr. 6 für Nachhaltige Entwicklung der UN, weltweit sauberes Wasser zur Verfügung zu stellen. Dafür sind schnelle, einfach zu bedienende und kostengünstige Überwachungssysteme notwendig. Antikörperbasierte Biosensoren haben das Potential, z.B. die Eliminationsleistung bezüglich kleiner organischer Moleküle durch die vierte Reinigungsstufe von Kläranlagen vor Ort zu überwachen. Darüber hinaus kommt modernen bioanalytischen Verfahren bei der Quantifizierung von Pathogenen eine immer wichtigere Rolle zu. Neben einer Bestandsaufnahme zu diesen Themen ist es das Ziel dieses Beitrags, die Anwendungsbarrieren von Biosensoren für die Wasseranalytik von Mikroschadstoffen abbauen zu helfen und die Vorzüge moderner bioanalytischer Methoden für die Quantifizierung von Pathogenen aufzuzeigen.
Alternative Tools (AT) such as on-site test kits, on-site portable devices and continuous measuring devices, are useful to improve water quality assessment under EU directives, and water treatment processes, thus contributing to improving water management, as well as get insights on the dynamic of pollutants within water bodies. Although these tools have clear advantages (e.g. fast response allowing for real-time monitoring, ease-of-use, lower cost), they are perceived as less reliable than conventional analytical methods. Their alternative nature, innovative status, and non-standard operation mode require specific validation strategies that differ significantly from those of conventional analytical methods. Nevertheless, the validation of ATs, especially on-site test kits, portable devices and continuous measuring devices for water quality monitoring is crucial to support their acceptance, promote their use and make their application sustainable. In this paper, a validation procedure in 4 steps is proposed: (1) Comprehensive description of the AT; (2) Assessment of intrinsic metrological performance and operational factors within a single laboratory; (3) Assessment of inter-laboratory performances through an inter-laboratory comparison and, (4) Demonstration of the equivalence of results between the AT and a reference method. This paper discusses each step of the validation procedure, and examples to illustrate critical issues are provided.
The environmental fate of the frequently used broad-spectrum β-lactam antibiotic amoxicillin (AMX) is of high concern regarding the potential evolution of antimicrobial resistance (AMR). Moreover, it is known that AMX is prone to hydrolysis, yielding a variety of hydrolysis products (HPs) with yet unknown effects. Studies to identify those HPs and investigate their formation mechanisms have been reported but a long-term study on their stability in real water samples was missing. In this regard, we investigated the hydrolysis of AMX at two concentration levels in four distinct water types under three different storage conditions over two months. Concentrations of AMX and four relevant HPs were monitored by an LC-MS/MS method revealing pronounced differences in the hydrolysis rate of AMX in tap water and mineral water on the one hand (fast) and surface water on the other(slow). In this context, the occurrence, relative intensities, and stability of certain HPs are more dependent on the water type than on the storage condition. As clarified by ICP-MS, the main difference between the water types was the content of the metals copper and zinc which are supposed to catalyze AMX hydrolysis demonstrating an effective method to degrade AMX at ambient conditions.
Functionalized Ti3C2Tx nanosheets based biosensor for point-of-care detection of SARS-CoV‑2 antigen
(2023)
MXenes are considered a promising class of two-dimensional materials with extraordinary physical and electrochemical properties. Distinguished features like high specific surface area and outstanding electrical conductivity make them suitable for electrochemical biosensing applications. Here, we report the development of a biosensor involving the functionalized MXene−titanium carbide nanosheets (Ti3C2Tx-NS) and monoclonal antibodies against the SARS-CoV-2 nucleocapsid protein (anti-SARS-CoV-2 mAb) to design a point-of-care device for detection of the SARS-CoV-2 nucleocapsid protein (SARS-CoV-2 NP) antigen. Few-layered titanium carbide nanosheets (denoted as FL-Ti3C2Tx-NS) have been synthesized using a single-step etching and delamination method and characterized using optical and electron microscopy techniques revealing the suitability for immunosensing applications. Binding studies revealed the excellent affinity between the biosensor and the SARS-CoV-2 NP. Electrochemical detection of SARS-CoV-2 NP is performed using differential pulse voltammetry and read by a smartphone-based user interface. The proposed FL-Ti3C2Tx-NS based biosensor offers the detection of SARS-CoV-2 NP with a limit of detection of 0.91 nM in a wide detection range in spiked saliva samples. Additionally, there is no cross-reactivity in the presence of potential interferants like SARS-CoV-2 spike glycoprotein and bovine serum albumin. These findings demonstrate the potential of MXenes in developing a rapid and reliable tool for SARS-CoV-2 NP detection. While we report the biosensing of SARS-CoV-2 NP, our system also paves the way for the detection of other SARS-CoV-2 antigens like spike protein or other biomolecules based on antigen−antibody interactions.
Im Vorhaben „MARKERIA - Bestimmung von anthropogenen Markerkonzentrationen für die SARS-CoV-2 Quantifizierung mittels eines Hochdurchsatzverfahrens (ELISA)“ geht es um die Bestimmung von Carbamazepin, Diclofenac, Koffein und einer endogenen Gallensäure als potentielle Marker für die Kalibrierung der SARS-CoV-2 Quantifizierung im Abwasser. Der Vortrag wurde gehalten im Rahmen der 22. Sitzung des Begleitkreises des übergeordneten Projektes ESI-CorA. Er gab den Projektstand wieder, den die BAM bis dahin erzielt hatte. Die Marker waren in sämtlichen untersuchten Abwasser-Zulaufproben enthalten und zeigten spezifische Trends. Weitere Korrelationen müsse die weitergehende Datenauswertung ergeben.A
Immunoassays, based on analyte recognition and capture by highly selective antibodies with high affinity, are intensively used in all fields of laboratory diagnostics and in screen-ings of food and environmental samples. Yet, for many purposes, online sensors are desir-able, and, in principle, all immunoassay tech-niques can be integrated into lab-on-chip set-ups that can work as continuous monitoring devices. Yet, the challenge remains to devel-op platforms and elements that are fit for a quick transition of laboratory microplate as-says to immunosensors.
The poster describes how molecular biology, especially recombinant expression of proteins, in this case, an enzyme, can underpin developments of biosensors. The fumonisin oxidase produced by the fungus Aspergillus niger (AnFAO) is highly selective for the toxic mycotoxin fumonisin. Its structure and sequence has been published before. We took this information and expressed the enzyme in E. coli. The enzyme proved active and could be employed in an amperometric biosensor for the detection of the mycotoxin.