Datei im Netzwerk der BAM verfügbar ("Closed Access")
Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (19)
- Vortrag (15)
- Zeitschriftenartikel (6)
- Posterpräsentation (5)
- Forschungsbericht (2)
Schlagworte
- Emission test chamber (10)
- VOC (9)
- Volatile organic compounds (7)
- Formaldehyd (6)
- Formaldehyde (6)
- VVOC (5)
- OSB (4)
- Particle board (4)
- Construction products (3)
- Emission (3)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (15)
There has been an increasing use of oriented strand boards (OSBs) for the construction of floors, ceilings and walls of buildings. In Germany and other European countries, OSBs are mainly produced from pine wood (Pinus sylvestris). In response to complaints about the odour and irritation of mucous membranes in connection with the use of OSBs, samples of OSBs were bought from do-it-yourself stores to test their volatile organic compound (VOC) emissions by using emission test chambers. The boards emitted predominantly monoterpenes, aldehydes, acids and acetone. Aldehydes are generated during the production process by the oxidation of unsaturated fatty acids such as linoleic acid. Pine wood, compared with other wood species, contains more unsaturated fatty acids. Of the six acquired OSBs, four boards from three manufacturers would not meet the requirements of the German AgBB (Ausschuss zur gesundheitlichen Bewertung von Bauprodukten, Committee for Health Evaluation of Building Products), mainly because of the emissions of unsaturated aldehydes. These compounds have low LCI values (lowest concentration of interest) and are therefore problematic substances based on a health-related evaluation of building products according to the AgBB scheme.
Wood and wood products are often used as construction material for buildings and even more for furniture and indoor decoration. Therefore Chemical emissions from wood have an influence on the indoor air quality. A research project financed by the Federal Environmental Agency focused on VOC emissions from oriented Strand boards (OSB) and also from plywood made from pine and spruce (Wilke et al., 2011a). This paper shows results of the plywood testing because only little information is available about plywood emission behaviour and its impact on indoor air quality.
11 laser printers from 5 manufacturers were purchased in 2017 and tested for their UFP emissions. Size resolved sampling of the emitted particles was done with a 13 stage (30 nm to 10 µm) low pressure cascade impactor. The sampled particles were analysed for their chemical composition by thermal extraction (vaporization at 290°C) followed by GC-MS analysis. High boiling cyclic siloxanes (D10 to D16) were detected as constituents of UFP from laser printers. In comparison to measurements in 2008, aliphatic long-chain alkanes (C22 to C34) were detected additionally as chemical constituents of UFP from most of the tested printers and their amounts were higher than for cyclic siloxanes. Printers of one manufacturer showed very low UPF emissions compared to the other manufacturers.
A screening test for potential emissions of volatile organic compounds (VOC) was run on different thermoplastic filaments used for 3D printing. The method of direct thermal desorption was used to simulate the high temperatures during the 3D printing process and to identify the main compounds emitted from the filaments. A )arge number of unexpected compounds were detected that might affect the user's health and have an impact on indoor air chemistry.
Der Innenraumluftrichtwert für Formaldehyd in Höhe von 0,1 ppm ist durch das BfR bestätigt worden und bleibt bis auf weiteres bestehen. Die Prüfbedingungen für Formaldehydemissionen aus Holzwerkstoffen dagegen sind nicht mehr aktuell. Das Prüfverfahren für Holzwerkstoffe gilt seit 1991 und basiert auf dem Gebäudestandard von 1984. Eine Definition und Anpassung der Prüfbedingungen an moderne „dichtere“ Bauweise ist notwendig. Es zeigt sich, dass für Verbraucherinnen und Verbraucher eine Unterscheidung von formaldehydbelasteten und -unbelasteten Produkten in der Praxis schwierig ist. Es kann zu fehlerhaftem Einsatz und nicht fachgerechter Verarbeitung der Holzwerkstoffe kommen. Das Ziel des Vorhabens ist die möglichst sichere Einhaltung des Schutzniveaus durch die Anpassung der Prüfbedingungen an den heutigen Gebäudestandard. Es werden das Projekt (UFOPLAN-Vorhaben FKZ 3714 95 310 0) und erste Messergebnisse vorgestellt. Erste Messungen von Holzwerkstoffen im laufenden Vorhaben unter „worst case“-Bedingungen (erhöhte Beladung, geringer Luftwechsel) zeigen hohe Formaldehyd-Emissionen.
A method for the determination of very volatile organic compounds (VVOC) in air was developed and successfully tested for methanol and ethanol. Carbotrap 300 (R) (a multi-bed tube using Carbopack C (R), Carbopack B (R) and Carbosive SIII (R)) was selected as sorption material for thermal desorption and tested for its suitability for emission test chamber measurements. The adsorption behaviour and the chromatographic results are influenced negatively by spiking aqueous solutions on the adsorption medium for calibration purposes. The latter effect can be reduced by blowing dry air across the adsorbent to remove the adsorbed water. Detection and quantification limits were determined for a GC-FID system and compared to GC-MS. The applicability of the method was tested with a methanol eliminating silane modified polymeric adhesive (SMP-adhesive for parquet) in an emission test chamber.
Im Januar 2018 wurde die DIN EN 16516 „Bauprodukte: Bewertung der Freisetzung gefährlicher Stoffe – Bestimmung von Emissionen in die Innenraumluft“ als harmonisierte europäische Prüfnorm veröffentlicht. Für die Etablierung der DIN EN 16516 als neue Referenznorm wurden verschiedene Emissionsprüfungen mit dem Ziel durchgeführt, ein neues Prüfverfahren für Formaldehydemissionen aus Holzwerkstoffen zu erarbeiten. Das übergeordnete Ziel ist die Minimierung des Risikos von Überschreitungen des Innenraumrichtwertes für Formaldehyd. Die Untersuchungen ergaben teilweise hohe Formaldehydemissionen, insbesondere bei höheren Beladungsfaktoren und Temperaturen, sowie bei niedrigen Luftwechselraten. Eine getestete Spanplatte hätte aufgrund ihrer hohen Formaldehydemission nicht auf den deutschen Markt gebracht werden dürfen. Durch vergleichende Untersuchungen konnte ein Umrechnungsfaktor in Höhe von 2,0 für die Umrechnung von Prüfwerten nach DIN EN 717-1 zu DIN EN 16516 abgeleitet werden.
The latest version of the German AgBB evaluation scheme (2015) for construction products includes some VVOC, e.g. formaldehyde, acetaldehyde and acetone. For these VVOC so-called LCI values (lowest concentration of interest) were derived which are used for the calculation of the so-called R-value (risk index, see reference 1 for the calculation). Test chamber measurements of particle boards show that the emissions of VVOC might have significant impact on the R-value and therefore for the health evaluation.
UBA und BAM schlagen die Durchführung der Prüfkammermessungen bei 23 °C und 50% relativer Luftfeuchte, einer Beladung von 1,8 m²/m³ und einem Luftwechsel von 0,5 pro Stunde vor. Diese Parameter orientieren sich an der EN 16516, die als zukünftige „Referenznorm“ zu betrachten ist. Die Schmalflächenversiegelung ist auch zukünftig wie in der EN 717-1 beschrieben vorzunehmen. Nach 28 Tagen wird der Mittelwert einer Doppelbestimmung als Endkonzentration („entsprechend der Ausgleichskonzentration“) berechnet. Alternativ dazu kann die Prüfung vorzeitig abgebrochen werden, wenn an 5 Messtagen der Prüfung eine Formaldehydkonzentration von 0,1 ppm nicht überschritten wird.
Prüfungen nach der EN 717-1 sollen weiterhin gleichberechtigt möglich sein. Ergebnisse von Messungen, die nach der EN 717-1 ermittelt wurden, sind mit dem Faktor 2,0 zu multiplizieren.
Abgeleitete Verfahren wie z.B. das Gasanalyseverfahren sollen weiterhin möglich sein. Das Perforatorverfahren entfällt hier, da eine allgemeine für alle Holzwerkstoffe gültige Korrelationen nicht existiert.
Die entsprechenden Änderungen sind in der vom BMUB veröffentlichten „Bekanntmachung analytischer Verfahren für Probenahmen und Untersuchungen für die im Anhang der Chemikalien-Verbotsverordnung genannten Stoffe und Stoffgruppen“ entsprechend zu ändern.
Comparison of Formaldehyde Concentrations in Emission Test Chambers Using EN 717-1 and EN 16516
(2018)
For more than 25 years EN 717-1 (Wood-based panels - Determination of formaldehyde re-lease - Part 1: Formaldehyde emission by the chamber method) is the standard for formalde-hyde emission testing of wooden boards. In 2017 EN 16516 (Construction products - Assess-ment of release of dangerous substances - Determination of emissions into indoor air) was published as a new harmonised standard for the emission testing of construction products. Because test chamber conditions are different, both standards give different concentrations for formaldehyde. To determine a conversion factor four test series were set up with different wooden boards. For a loading of 1 m²/m³ the conversion factor is 1.6. This means that the formaldehyde concentration measured under the conditions of EN 16516 is a factor of 1.6 higher compared to EN 717-1.