Probability of detection analysis of round robin test results performed by flash thermography
(2016)
Within the scope of a standardisation research project, a flash thermography round robin test that evaluates reliability, comparability and efficiency of different testing situations was performed. Data recorded at metal test specimens with flat bottom holes (FBHs) were analysed by calculating the signal-to-noise ratio (SNR) of the defect signatures in the thermograms as well as in the phase images as a function of defect parameters. A new multi-parameter probability of detection (POD) model was developed, where an â versus a continuous signal analysis was based on the linear relationship between the SNR and a multi-parameter a. This linear relationship was verified by comparison to data obtained from an analytical model that is considering lateral thermal heat diffusion as well as to data obtained by numerical simulation. The resulting POD curves for the thermograms and phase images give an estimation for the detectability of the FBHs with known geometry in steel using different equipment and obtained by different participants. By comparing the SNRs of FBHs with similar geometries, this POD model was transferred to aluminium and copper as well.
Within the scope of a DIN INS project, a flash thermography round robin test that evaluates reliability, comparability, and efficiency of different testing situations was organized. The results give information about the detectability of defects, e.g. depending on their size and depth, the evaluation methods and the materials used. Besides, the influences of equipment and parameters used by the participants on the results were analysed. All of the quantitative results as well as the feedback given by the participants will be presented in a DIN committee in order to contribute to a flash thermography standard.
Recently, first analyses of single sub-micrometre particles, embedded in liquid droplets, by inductively coupled plasma optical emission spectrometry (ICP-OES) with a size-equivalent detection limit of several hundred nanometres were reported.1,2 To achieve lower detection limits which might allow for the analysis of particles in the nanometre size range a more sensitive technique such as mass spectrometry (MS) is required. Various modifications of particle delivery and data acquisition systems commonly used were carried out to install a setup adequate for ICP-MS detection. These modifications enabled us to supply droplets generated by a commercial microdroplet generator (droplet size: 3040 µm) with nearly 100% efficiency and high uniformity to the ICP. Analyses were performed using both standard solutions of dissolved metals at concentrations of 1 (Ag), 2 (Au), 5 (Au), or 10 (Cu) mg L-1 and highly diluted suspensions of gold and silver nanoparticles with sizes below 110 nm. In doing so, detection efficiencies of 10-6 counts per atom could be achieved while size-related limits of quantification were found to be 21 nm and 33 nm for gold and silver, respectively. Furthermore, the advantages of utilizing microdroplet generators vs. conventional nebulizers for nanoparticle analyses by ICP-MS are discussed.