8.3 Thermografische Verfahren
Filtern
Dokumenttyp
- Vortrag (87)
- Zeitschriftenartikel (65)
- Beitrag zu einem Tagungsband (37)
- Posterpräsentation (21)
- Preprint (4)
- Buchkapitel (1)
- Dissertation (1)
- Sonstiges (1)
Sprache
- Englisch (217) (entfernen)
Schlagworte
- Thermography (99)
- NDT (35)
- Additive Manufacturing (30)
- Super resolution (28)
- Additive manufacturing (27)
- Laser thermography (21)
- Process monitoring (14)
- Internal defects (13)
- Thermografie (13)
- DLP (12)
Organisationseinheit der BAM
- 8.3 Thermografische Verfahren (217)
- 8 Zerstörungsfreie Prüfung (216)
- 9 Komponentensicherheit (42)
- 9.3 Schweißtechnische Fertigungsverfahren (25)
- 8.5 Röntgenbildgebung (20)
- 9.6 Additive Fertigung metallischer Komponenten (20)
- 8.4 Akustische und elektromagnetische Verfahren (8)
- 1 Analytische Chemie; Referenzmaterialien (7)
- 5 Werkstofftechnik (7)
- 1.9 Chemische und optische Sensorik (5)
- 7 Bauwerkssicherheit (5)
- 9.4 Integrität von Schweißverbindungen (5)
- 4 Material und Umwelt (3)
- 5.1 Mikrostruktur Design und Degradation (3)
- 5.4 Multimateriale Fertigungsprozesse (3)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (3)
- 2 Prozess- und Anlagensicherheit (2)
- 2.1 Sicherheit von Energieträgern (2)
- 4.2 Material-Mikrobiom Wechselwirkungen (2)
- 5.0 Abteilungsleitung und andere (2)
- 6 Materialchemie (2)
- 6.3 Strukturanalytik (2)
- 7.5 Technische Eigenschaften von Polymerwerkstoffen (2)
- 1.4 Prozessanalytik (1)
- 1.6 Anorganische Referenzmaterialien (1)
- 4.5 Kunst- und Kulturgutanalyse (1)
- 5.2 Metallische Hochtemperaturwerkstoffe (1)
- 7.1 Baustoffe (1)
- 7.2 Ingenieurbau (1)
- 7.4 Baustofftechnologie (1)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (1)
- 8.6 Faseroptische Sensorik (1)
- S Qualitätsinfrastruktur (1)
- S.0 Abteilungsleitung und andere (1)
Paper des Monats
- ja (3)
For assuring the safety and reliability of components and constructions in energy applications made of fiber-reinforced polymers (e.g., blades of wind turbines and tidal power plants, engine chassis, flexible oil and gas pipelines) innovative non-destructive testing methods are required. Within the European Project VITCEA complementary methods (shearography, microwave, ultrasonics and thermography) have been further developed and validated. Together with partners from the industry, test specimens have been constructed and selected on-site containing different artificial and natural defect artefacts. As base materials, carbon and glass fibers in different orientations and layering embedded in different matrix materials (epoxy, polyamide) have been considered. In this contribution, the validation of flash and lock-in thermography to these testing problems is presented. Data analysis is based on thermal contrasts and phase evaluation techniques. Experimental data are compared to analytical and numerical models. Among others, the influence of two different types of artificial defects (flat bottom holes and delaminations) with varying diameters and depths and of two different materials (CFRP and GFRP) with unidirectional and quasi-isotropic fiber alignment is discussed.
We present an in situ triple coupling of synchrotron X-ray diffraction with Raman spectroscopy, and thermography to study milling reactions in real time. This combination of methods allows a correlation of the structural evolution with temperature information. The temperature information is crucial for understanding both the thermodynamics and reaction kinetics. The reaction mechanisms of three prototypical mechanochemical syntheses, a cocrystal formation, a C@C bond formation (Knoevenagel condensation), and the formation
of a manganese-phosphonate, were elucidated. Trends in the temperature development during milling are identified. The heat of reaction and latent heat of crystallization of the product contribute to the overall temperature increase. A decrease in temperature occurs via release of, for example, water as a byproduct.
Solid and liquid intermediates are detected. The influence of the mechanical impact could be separated from temperature effects caused by the reaction.
Pulse thermography (PT) has proven to be a valuable non-destructive testing method to identify and quantify defects in fiber-reinforced polymers. To perform a quantitative defect characterization, the heat diffusion within the material as well as the material parameters must be known. The heterogeneous material structure of glass fiber-reinforced polymers (GFRP) as well as the semitransparency of the material for optical excitation sources of PT is still challenging. For homogeneous semitransparent materials, 1D analytical models describing the temperature distribution are available.
Here, we present an analytical approach to model PT for laterally inhomogeneous semitransparent materials.We show the validity of the model by considering different configurations of the optical heating source, the IR camera, and the differently coated GFRP sample. The model considers the lateral inhomogeneity of the semitransparency by an additional absorption coefficient. It includes additional effects such as thermal losses at the samples surfaces, multilayer systems with thermal contact resistance, and a finite duration of the heating pulse. By using a sufficient complexity of the analytical model, similar values of the material parameters were found for all six investigated configurations by numerical fitting.
Additive manufacturing (AM) opens the route to a range of novel applications.However, the complexity of the manufacturing process poses a challenge for the production of defect-free parts with a high reliability. Since process dynamics and resulting microstructures of AM parts are strongly influenced by the involved temperature fields, thermography is a valuable tool for process surveillance. The high process temperatures in metal AM processes allow one to use cameras usually operating in the visible spectral range to detect the thermally emitted radiation from the process. In our work, we compare the results of first measurements during the manufacturing processes of a commercial laser metal deposition (LMD) setup and a laser beam melting (LBM) setup using a MWIR camera with those from a VIS high-speed camera with band pass filter in the NIR range.
Additive manufacturing (AM) offers a range of novel applications. However, the manufacturing process is complex and the production of defect-free parts with a high reliability is still a challenge. Thermography is a valuable tool for process surveillance, especially in metal AM processes. The high process temperatures allow one to use cameras usually operating in the visible spectral range. Here, we compare the results of first measurements during the manufacturing process of a commercial laser metal deposition (LMD) setup using a MWIR camera with those from a VIS high-speed camera with band pass filter in the NIR range.
In flash thermography, the temperature transient is strongly influenced by the temporal shape of the heating pulse for samples with high thermal diffusivity or very thin samples. Here, we present a closed phenomenological approximation of the temporal shape of pulses of Xe-flash lamps. It is a non-stitched solution, has a simple Laplace transform and is suitable for different lamps and energy settings. It is demonstrated that simulated temperature transients, based on this approximation, are well consistent with experimental data.
In the field of optically excited thermography, flash lamps (impulse shaped planar heating) and halogen lamps (modulated planar heating) have become established for the specific regimes of impulse and lock-in thermography. Flying-spot laser thermography is implemented by means of a rasterized focused laser, e. g. for crack detection (continuous wave operation) and photothermal material characterization (high-frequency modulated). The availability of novel technologies, i. e. fast and high-resolution IR cameras, brilliant innovative light sources and high-performance data acquisition and processing technology will enable a paradigm shift from stand-alone photothermal and thermographic techniques to uniform quantitative measurement and testing technology that is faster and more precise. Similar to an LED array, but with irradiance two orders of magnitude higher, a new type of brilliant laser source, i. e. the VCSEL array (vertical-cavity surface-emitting laser), is now available. This novel optical energy source eliminates the strong limitation to the temporal dynamics of established light sources and at the same time is spectrally clearly separated from the detection wavelength. It combines the fast temporal behavior of a diode laser with the high optical irradiance and the wide illumination area of flash lamps. In addition, heating can also be carried out in a structured manner, because individual areas of the VCSEL array can be controlled independently of each other. This new degree of freedom enables the development of completely new thermographic NDT methods.
Influence of the real energy input on the sensitivity of thermographic testing in case of GFRP
(2018)
Thermographic testing (TT) is an upcoming nondestructive method, which requires no contact at all to the specimen and can be applied on larger areas simultaneously. The measurement concept is based on the production of a thermal imbalance at the surface of the object under test. When the surface of this object is heated by an external source for a certain time, the surface temperature drops subsequently, influenced by inner defects of the sample. This leads to thermal contrasts at the surface. It is crucial that those contrasts are large enough to be detectable above the noise level. In a first approximation, the observed temperature contrast at a defect is proportional to the energy which was really introduced into the specimen during the heating period. However, the real energy input in a TT experiment is almost always unknown due to distinct parameters of the experimental setup or the material investigated. Typically, only the power consumption of the heating sources is reported, sometimes combined with the distance to the specimen surface.
This contribution describes the thermographic inspection of a rear side thickness variation from 1 to 2 cm at GFRP. This could represent a rear side adhesive bond i.e. in a wind turbine rotor blade. The front side heating was realized by usual halogen lamps with variable radiation power. The detected temperature contrast at the front side will be related to the different energy inputs determined by means of a simple analytical model applied to the experimental data. Additionally, the experimental data are compared with results of FEM simulations performed by COMSOL Multiphysics.
The results clearly demonstrate the key role of the real energy input in a real TT setup, if detection limits have to be evaluated.
Systematic errors in the evaluation of uncorrected data from thermographic lock-in measurements
(2018)
Lock-in thermography (LT) is based on the correct evaluation of phase differences between the temperature oscillations at different surface regions of the object under test during periodic heating. Since the usual heating procedures contain a DC component, the actual heating pattern achieved is not harmonic. This causes systematic deviations when phase differences are determined by means of harmonic analysis, e.g. with FFT analysis. The resulting errors depend clearly on the ratio between DC and AC amplitude, which is demonstrated at simulated and experimentally recorded temperature transients. Further experimental LT data obtained by different oscillating energy inputs showed a variety of possible shapes of transients with different DC components.
Active thermography with flash and halogen light excitation is used as a method for non-destructive testing of 3D-printed polymer components. Test specimens with artificial defects have been generated, using laser sintering and fused layer modeling. These test specimens have been investigated in different measurement configurations with both excitation methods. Afterwards, the different measurement conditions were compared regarding their capability to detect the defects. Furthermore, advanced analysis methods are used, to fully exploit the capabilities of these techniques.