In structural parts under vibrational loading fatigue cracks can initiate and grow, which can lead to structural failure. Conventional non-destructive testing methods for crack detection provide just a snapshot of fatigue crack evolution, whereas crack luminescence coating realizes clear visibility of the entire crack formation. Fatigue causing cyclic tensile tests and examinations on special test bodies allowing control of the crack opening width demonstrate a high sensitivity of the coating.
Messtechnische Systeme zur Dauerüberwachung von Bauwerken ermöglichen Einblicke in deren reale Trag- und Verformungsverhalten. Die Planung und technische Umsetzung solcher Maßnahmen erfordern für die erfolgreiche Erfüllung der Aufgabenstellungen eine hohe Fachkompetenz, sowohl auf der planerischen Seite, als auch für die fachliche Bewertung von angebotenen Monitoringlösungen. Als Hilfestellung dafür wurde von der Deutschen Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) das Merkblatt „Dauerüberwachung von Ingenieurbauwerken“ erarbeitet, welches nun verfügbar ist. In diesem Beitrag werden die Inhalte des neuen Merkblatts vorgestellt und dieses in die vorhandene Literatur eingeordnet.