This paper presents an experimental study on the hydraulic failure of a submerged layer of cemented soil stressed by a localized upward water flow. Different mixtures of glass beads bonded with solid paraffin bridges were used as artificial material for the cemented granular soil. Variations in the cementation strength of the material were carefully introduced with different particle sizes and binder contents. The hydraulic fracture tests were then carried out with an upward flow injected at a controlled rate through a small section at the bottom of the samples. From a phenomenological perspective, the results reveal the existence of at least three modes of failure for a cemented soil layer: (1) overall block uplift, (2) block rupture by median crack at the inflow zone, and (3) progressive excavation of a fluidized path along the walls. The critical flow rate and pressure drop conditions at failure have been carefully quantified for the different mixtures and layer thicknesses, leading to a fair estimation of the hydraulic resistance of the samples, which here is found to be virtually independent of the grain size. However, the test results also showed inconsistent failure modes precluding so far the derivation of a simple phase diagram. Nevertheless, it was possible to rationalize all the measured data by employing appropriate modifications of the classical dimensionless numbers that describe the fluidization of purely frictional materials, whereby the cementation strength of the soil is quantified at the microscale through the yield tensile force of the intergranular bonds. Irrespective of its subsequent development, during which boundary conditions obviously play a major role, the initiation of the instability appears to take place very locally at the inlet when the drag force induced by the flow overcomes the cementation strength of the paraffin bonds. The results of this study thus appear to endorse the extension of the dimensional relationships of particulate systems in interaction with fluid flows to the case of cemented granular materials, in a similar vein as in recent previous studies.
Structural Health Monitoring (SHM) wird zunehmend zur kontinuierlichen Zustandsbewertung von Ingenieurbauwerken eingesetzt. Wichtige Bewertungsparameter sind globale Systemeigenschaften, wie z. B. Eigenfrequenzen, zu deren Bestimmung Beschleunigungssensoren eingesetzt werden. Häufig werden sog. MEMS-Sensoren (Micro Electro Mechanical Systems) verwendet, die jedoch ein hohes Rauschniveau aufweisen. Alternativ können rauschärmere IEPE-Sensoren (Integrated Electronics Piezo Electric) eingesetzt werden, die auch bei geringster Strukturanregung Schwingungen zuverlässig erfassen. Ferner besteht das Problem, dass Änderungen der Eigenfrequenzen infolge Bauwerksschädigung schwer von Änderungen der Eigenfrequenzen infolge Umwelteinflüssen zu unterscheiden sind. Letztere verändern die Eigenschaften der Struktur und die des Messsystems. Um Umwelteinflüsse auf das Messsystem im Anwendungsgebiet Ingenieurbau zu untersuchen, wurden IEPE-Beschleunigungsaufnehmer hinsichtlich ihres Übertragungsverhaltens im niederfrequenten Beschleunigungsbereich analysiert. Es zeigt sich, dass das Verhalten nicht nur frequenz-, sondern auch temperaturabhängig ist, während die Luftfeuchte keinen Einfluss hat. Diese für das Bauwerk unbedenklichen Einflüsse müssen für eine robuste Zustandsüberwachung kompensiert werden. Für die Anwendung im Ingenieurbau werden IEPE-Sensoren empfohlen, da sie ein hohes Signal-zu-Rausch-Verhältnis aufweisen und niederfrequente Bauwerksschwingungen zuverlässig erfassen.
Im Forschungsprojekt DiMoWind-Inspect wurde untersucht, welche Grundvoraussetzungen geschaffen werden müssen, um digitale Methoden für die Instandhaltung von Offshore-Windenergieanlagen einsetzen zu können. Daten aus allen Lebensphasen der Anlagen werden derzeit nur selten effizient dafür genutzt, um die sinnvollsten Instandhaltungsmaßnahmen am richtigen Ort, zum richtigen Zeitpunkt und mit den geringsten Kosten durchzuführen. Eine im Vorhaben entwickelte einheitliche Strukturierung der bisher häufig unstrukturierten Bau- und Instandhaltungsdaten ermöglicht ihre übergreifende, anwenderspezifische Verfügbarkeit. Hierfür werden Prinzipien des Referenzkennzeichnungssystems RDS-PP adaptiert. Es wird aufgezeigt, wie neben Bauteilen auch zusätzliche Informationen wie Instandhaltungsmaßnahmen oder Mängel strukturiert werden können. Dem Ansatz des Building Information Modeling folgend werden die Bauwerkskomponenten direkt mit den Informationen aus Inspektionen und weiteren Instandhaltungsmaßnahmen verknüpft. So können Informationen aus dem Betrieb über den Zustand der Struktur verarbeitet und für die maßgebenden Berechnungen und Nachweise zur Verfügung gestellt werden. Als Anwendungsfall wird ein zweistufiges Konzept vorgestellt, das zur Bewertung der Ermüdungslebensdauer eines korrosionsgeschädigten Konstruktionsdetails der Gründungsstruktur einer Offshore-Windenergieanlage mit Informationen aus der Instandhaltung eingesetzt wird.
The Bundesanstalt für Materialforschung und -prüfung (BAM) collaborates with TNO to develop a software framework for automated calibration of structural models based on monitoring data. The ultimate goal is to include such models in the asset management process of engineering structures. As a basis for developing the framework, a multi-span road bridge consisting of ten simply supported steel box girders was selected as a test case. Our group measured output-only vibration data from one box girder under ambient conditions. From the data, we determined eigenfrequencies and mode shapes. In parallel, we developed a preliminary structural model of the box girder for the purpose of predicting its modal properties. In this contribution, we provide an overview of the measurement campaign, the operational modal analysis, the structural modeling and qualitatively compare the identified with the predicted modes. As an outlook, we discuss the further steps in the calibration process and future applications of the calibrated model.
Managing aging engineering structures requires damage identification, capacity reassessment, and prediction of remaining service life. Data from structural health monitoring (SHM) systems can be utilized to detect and characterize potential damage. However, environmental and operational variations impair the identification of damages from SHM data. Motivated by this, we introduce a Bayesian probabilistic framework for building models and identifying damage in monitored structures subject to environmental variability. The novelty of our work lies (a) in explicitly considering the effect of environmental influences and potential structural damages in the modeling to enable more accurate damage identification and (b) in proposing a methodological workflow for model‐based structural health monitoring that leverages model class selection for model building and damage identification. The framework is applied to a progressively damaged reinforced concrete beam subject to temperature variations in a climate chamber. Based on deflections and inclinations measured during diagnostic load tests of the undamaged structure, the most appropriate modeling approach for describing the temperature‐dependent behavior of the undamaged beam is identified. In the damaged state, damage is characterized based on the identified model parameters. The location and extent of the identified damage are consistent with the cracks observed in the laboratory. A numerical study with synthetic data is used to validate the parameter identification. The known true parameters lie within the 90% highest density intervals of the posterior distributions of the model parameters, suggesting that this approach is reliable for parameter identification. Our results indicate that the proposed framework can answer the question of damage identification under environmental variations. These findings show a way forward in integrating SHM data into the management of infrastructures.
Nowadays geotechnical engineering firms have powerful software tools to extent their consult-ing business also into dynamic soil-structure interaction, which before has been restricted to a rather small community of specialized experts in this field, and they certainly do. This is par-ticularly true with respect to non-seismic sources, that is all kinds of human induced vibrations. Hence, there is a demand from clients as well as from contractors to have guidance on the re-quirements as well as the limits of numerical modelling of soil-structure interaction. From the literature as well as from relevant standards, recommendations for the numerical modelling of soil-structure interaction problems involving seismic actions are well known, e. g. ASCE/SEI 4-16. There are, however, some particularities when dealing with human-induced vibrations, which are absent in seismic analyses. For human-induced excitations very little specific guid-ance has been published in the past. A machine foundation on a homogeneous half space ex-cited by harmonic loads with excitation frequency between 4 Hz and 64 Hz has been ana-lysed by means of several commercially available software packages. Parametric studies have been performed to verify if recommendations for seismic soil-structure analyses are valid for non-seismic analyses as well. This paper provides details on the benchmark example and the most important conclusions from the undertaken parametric studies.
ISO 14837-32:2015 and DIN EN 1998-1/NA:2021 as well as prEN 1997-2:2022 allow for us-ing correlations between the results of in-situ soil penetration tests and shear wave velocity (or shear modulus) to determine soil properties to be used in dynamic analyses. While the ISO and prEN standards even provide some recommendations on specific correlations to be used, the DIN standard does not. Due to the statistical nature of such correlations their general applica-bility has to be verified. We collected data sets from test sites from Germany as well as New Zealand at which cone penetration tests (CPT) as well as seismic site investigation methods were conducted. These sites comprise sandy soils as well as clayey soils, mixed soils as well as glacial soils. We compare the results of several correlations between CPT results and shear wave velocity. The accuracy of such correlations is assessed with respect to the accuracy of seismic in-situ tests. It turns out that for clean sands such correlations between CPT and Vs have a similar order of variability as seismic in-situ tests conducted at the same site. The higher the fines portion of the soil, the higher the variability of the statistical correlations, and conse-quently the less the general applicability. For glacial soils and other special soil types usage of statistical correlations to determine dynamic soil properties is not recommended.
Wind turbines are exposed to a high number of load cycles during their service lifetime. Therefore, the fatigue strength verification plays an important role in their design. In general, the nominal stress method is used for the fatigue verification of the most common used butt-welded joints. The Eurocode 3 part 1–9 is the current design standard for this field of application. This paper presents recent results of fatigue tests on small-scaled specimens and large components with transverse butt welds to discuss the validity of the FAT-class. Furthermore, results from numerical simulations for the verification with the effective notch stress and the crack propagation approach are used for comparison. Based on the consistency between the numerical results and the fatigue tests, the influence of the seam geometry on the fatigue resistance was investigated. Finally, a prediction of the fatigue strength of butt-welded joints with plate thicknesses up to 80 mm was carried out.
Acceleration sensors are vital for assessing engineering structures by measuring properties like natural frequencies. In practice, engineering structures often have low natural frequencies and face harsh environmental conditions. Understanding sensor behavior on such structures is crucial for reliable masurements. The research focus is on understanding the behavior of acceleration sensors in harsh environmental conditions within the low-frequency acceleration range. The main question is how to distinguish sensor behavior from structural influences to minimize errors in assessing engineering structure conditions. To investigate this, the sensors are tested using a long-stroke calibration unit under varying temperature and humidity conditions. Additionally, a mini-monitoring system configured with four IEPE sensors is applied to a small-scale support structure within a climate chamber. For the evaluation, a signal-energy approach is employed to distinguish sensor behavior from structural behavior. The findings show that IEPE sensors display temperature-dependent nonlinear transmission behavior within the low-frequency acceleration range, with humidity having negligible impact. To ensure accurate engineering structure assessment, it is crucial to separate sensor behavior from structural influences using signal energy in the time domain. This study underscores the need to compensate for systematic effects, preventing the underestimation of vibration energy at low temperatures and overestimation at higher temperatures when using IEPE sensors for engineering structure monitoring.
We evaluate masked block-structured grids for ocean domains which allow to represent small-scale geometric features without resorting to very small blocks or excessive mesh resolution. The considered approach aims to combine the geometric flexibility of unstructured meshes with the computational efficiency of stencil-based discretizations and is implemented and tested in a quadrature-free discontinuous Galerkin shallow water solver. We investigate the accuracy and the computational performance of the scheme on a range of realistic ocean domains meshed with blocks of different size and provide some comparisons to results obtained on unmasked block-structured grids and unstructured meshes.