6.2 Material- und Oberflächentechnologien
Filtern
Dokumenttyp
Referierte Publikation
- nein (166) (entfernen)
Schlagworte
- Laser-induced periodic surface structures (LIPSS) (46)
- Surface functionalization (24)
- Corrosion (23)
- Femtosecond laser (19)
- Applications (16)
- Femtosecond laser ablation (11)
- Laser processing (11)
- Laser-induced periodic surface structures, LIPSS (11)
- MIC (10)
- Materialbearbeitung (9)
Organisationseinheit der BAM
- 6 Materialchemie (166)
- 6.2 Material- und Oberflächentechnologien (166)
- 4 Material und Umwelt (26)
- 4.1 Biologische Materialschädigung und Referenzorganismen (26)
- 9 Komponentensicherheit (22)
- 6.1 Oberflächen- und Dünnschichtanalyse (17)
- 9.5 Tribologie und Verschleißschutz (15)
- 9.0 Abteilungsleitung und andere (7)
- 6.7 Materialsynthese und Design (6)
- 1 Analytische Chemie; Referenzmaterialien (4)
Paper des Monats
- ja (1)
Spurenelemente spielen eine wichtige Rolle bei der Verfeinerung der Eigenschaften von komplexen Materialien. Diese Arbeit zeigt die Korrelation zwischen der Mikrostruktur, der Gitterfehlpassung und den Kriecheigenschaften. Die Legierung Al10Co25Cr8Fe15Ni36Ti6 (in at. %) mit komplexer Zusammensetzung wurde mit den Elementen Hf und W verstärkt. Die Zugabe von Hf bewirkt eine eckigere Form der würfelförmigen gamma'-Ausscheidungen und einen erhöhten Anteil der Heusler-Phase. Die Zugabe von W wiederum formt die Würfelchen rundlicher und löst die Heusler-Phase auf. Eine Mischung der beiden Spurenelemente zeigt einen Übergang zwischen den beiden Extremen, sowohl in Hinsicht auf die Form der Ausscheidungen als auch in Bezug auf die Gitterfehlpassung und die Kriecheigenschaften.
Ultrashort pulse laser micromachining at repetition rates of several hundreds of kHz allows a cost-effective high precision manufacturing, which makes this method attractive for many industrial applications. Upon exceeding a critical laser intensity, hard X-ray radiation is generated as a side effect. Even if the emitted X-ray dose per laser pulse is low, for currently available high-repetition-rate laser systems the accumulated X-ray dose becomes significant and radiation safety must be considered. Influences of the processing parameters are discussed and radiation protection aspects will be outlined
The industrial use of ultrashort laser pulses has made considerable progress in recent years. The reasons for this lie in the availability of high average powers at pulse repetition rates in the several 100 kHz range. The advantages of using ultrashort laser pulses in terms of processing precision can thus be fully exploited. However, high laser intensities on the workpiece can also lead to the generation of unwanted X-rays. Even if the emitted X-ray dose per pulse is low, the accumulated X-ray dose can become significant for high-repetition-rate laser systems so that X-ray exposure safety limits must be considered. The X-ray emission during ultrashort pulse laser processing was investigated for a pulse duration of 925 fs at 1030 nm wavelength and 400 kHz repetition rate. Industrially relevant materials such as steel, aluminum and glass were treated. Tungsten served as reference. X-ray spectra were recorded, and X-ray dose measurements were performed for laser treatment in air. For laser intensities > 2 × 10^13 W/cm2, X-ray doses exceeding the regulatory exposure limits for members of the public were found. Suitable X-ray protection strategies are proposed.
Ultrashort laser pulse micromachining features a high precision. By increasing the repetition rate of the applied laser to several 100 kHz, laser processing becomes quick and cost-effective and make
this method attractive for industrial applications. Upon exceeding a critical laser intensity, hard X-ray radiation is generated as a side effect. Even if the emitted X-ray dose per pulse is low, the accumulated X-ray dose becomes significant for high-repetition-rate laser systems so that radiation
safety must be considered.
Ultrashort laser pulse micromachining features a high precision. By increasing the repetition rate of the applied laser to several 100 kHz, laser processing becomes quick and cost-effective and make this method attractive for industrial applications. Upon exceeding a critical laser intensity, hard X-ray radiation is generated as a side effect. Even if the emitted X-ray dose per pulse is low, the accumulated X-ray dose becomes significant for high-repetition-rate laser systems so that radiation safety must be considered.
Ultrashort laser pulse micromachining features a high precision. By increasing the repetition rate of the applied laser to several 100 kHz, laser processing becomes quick and cost-effective and make this method attractive for industrial applications. Upon exceeding a critical laser intensity, hard X-ray radiation is generated as a side effect. Even if the emitted X-ray dose per pulse is low, the accumulated X-ray dose becomes significant for high-repetition-rate laser systems so that radiation safety must be considered. The X-ray emission during ultrashort laser processing was investigated for an intensity range up to 2.6*10^14 W/cm2. The investigations were performed with a laser emitting pulses with 925 fs pulse duration, at 1030 nm wavelength and 400 kHz repetition rate. Steel, tungsten, and glass were studied in ambient air. Corresponding X-ray spectra and X-ray dose measurements were presented. Suitable radiation protection strategies were shown.
Ultrashort laser pulse micromachining features a high precision. By increasing the repetition rate of the applied laser to several 100 kHz, laser processing becomes quick and cost-effective and make this method attractive for industrial applications. Upon exceeding a critical laser intensity, hard X-ray radiation is generated as a side effect. Even if the emitted X-ray dose per pulse is low, the accumulated X-ray dose becomes significant for high-repetition-rate laser systems so that radiation safety must be considered.
Hochentropie-Legierungen (HEAs) zeichnen sich durch einen Mischkristall-System aus mindestens fünf und Mittelentropie-Legierungen (MEAs) durch mindestens drei Hauptlegierungselemente aus, in äquiatomarer Zusammensetzung. Sie zeigen außergewöhnliche Anwendungseigenschaften, wie z.B. hohe Festigkeit, Duktilität oder Korrosionsbeständigkeit. Zukünftige HEA/MEA-Komponenten aufgrund ihrer Eigenschaften für wasserstoffhaltige Umgebungen (wie Behälter für kryogene oder Hochdruckspeicherung) von Interesse. Daher ist die Bewertung der Wasserstoffabsorption und die Diffusion in diesen Materialien von großer Bedeutung. Dazu wurden in unserer Studie eine CoCrFeMnNi-HEA und eine CoCrNi-MEA untersucht. Die Proben wurden elektrochemisch mit Wasserstoff beladen. Für die Ermittlung des Wasserstoffdiffusionsverhaltens wurde die thermische Desorptionsanalyse (TDA) mit unterschiedlichen Heizraten bis zu 0,250 K/s angewandt. Die nachfolgende Peakentfaltung der Signale führte zu Hochtemperatur-Desorptionsspitzen und Wasserstofftrapping auch über 280°C. Eine resultierende Gesamtwasserstoffkonzentration > 40 ppm wurde für den MEA ermittelt und > 100 ppm für den HEA. Dies deutet auf zwei wichtige Effekte hin:
(1) verzögerte Wasserstoffdiffusion und (2) eine beträchtliche Menge an getrapptem Wasserstoff auch bei hoher Temperatur. Beide Effekte können hinsichtlich einer wasserstoffunterstützten Rissbildung kritisch werden, dies erfordert jedoch weitere Untersuchungen. Zusätzlich erfolgte die Bestimmung des lokalen Volta-Potentials mittels hochauflösender Kelvin-Sonden-Kraft-Mikroskopie (SKPFM). Die ermittelten Scans zeigen einen bestimmten Einfluss der Wasserstoffbeladung auf die Potentiale.
Unwanted X-ray emission in ultrashort pulse laser processing: From metallic to biological materials
(2023)
Ultrashort laser pulses have become established in many industrial processes. Additionally, they are also an integral part of medical applications especially in ophthalmology and to some extent in dentistry. The availability of highly repetitive powerful laser sources and advanced laser beam control systems have favored these developments. However, the laser processing may be accompanied by the generation of unwanted X-rays. Small doses per laser pulse can accumulate to significant dose levels at high laser pulse repetition rates. Moreover, burst mode processing increases the X-ray dose rates compared to single pulse use and results in X-ray photon energies up to 40 keV for tungsten targets. For laser treatment of human teeth, clearly noticeable X-ray skin dose rates can be found. The paper summarizes the current state of the art in the field of undesired generation of X-ray radiation during ultrashort pulse laser processing in air.
Unwanted X-ray emission in ultrashort pulse laser processing: From metallic to biological materials
(2023)
X-rays can be generated as an unwanted side effect during ultrashort pulse laser material processing of technical work pieces and even biological samples with laser intensities above 10^13 W/cm^2. First studies demonstrate the need to address this effect in industrial as well as in medical applications. This secondary hazard should be considered in work safety and risk assessment.