5 Werkstofftechnik
Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (54) (entfernen)
Sprache
- Englisch (54) (entfernen)
Referierte Publikation
- nein (54) (entfernen)
Schlagworte
- Corrosion (13)
- CCS (5)
- CO2 (5)
- Steel (4)
- Aluminium (3)
- CCUS (3)
- CO2 quality (3)
- Carbon steel (3)
- Fatigue (3)
- Geothermal (3)
- Impurities (3)
- Martensitic steel (3)
- Pipeline network (3)
- Additive manufacturing (2)
- Adiabatic calorimeter (2)
- Alloy 2618A (2)
- CCU (2)
- CO2-storage (2)
- Carbon steels (2)
- Coarsening (2)
- Crack growth (2)
- Creep (2)
- EN AW-2618A (2)
- Glass fiber reinforced polymers (2)
- Inconel 686 (2)
- P92 (2)
- Phase change material (2)
- Pipeline (2)
- Polyaniline (2)
- Recommendations (2)
- Salt eutectics (2)
- SiO2 (2)
- Superaustenite steel (2)
- Supercritical CO2 (2)
- Supercritical/dense phase CO2 (2)
- Tempered Martensite Ferritic Steels (2)
- Thermal energy storage (2)
- Thermomechanical fatigue (2)
- Transmission electron microscopy (2)
- Utilization (2)
- Whole-chain CCS scenario (2)
- Wind turbine blades (2)
- Aggressive environment (1)
- Air-coupled ultrasonic testing (1)
- Airborne ultrasonic testing (1)
- Alloy 2818A (1)
- Alumina (1)
- Aluminium alloy (1)
- Aluminum alloys (1)
- Anisotropy (1)
- Automated finite element analysis (1)
- Automatische Finite Element Simulation (1)
- Biofilm (1)
- Burst test (1)
- CO2 Corrosion (1)
- Capture (1)
- Carbon (1)
- Carbon capture (1)
- Carbon capture storage (1)
- Casting (1)
- Cement (1)
- Coating (1)
- Coatings (1)
- Composite (1)
- Composite pressure vessels (1)
- Composite structures (1)
- Composites (1)
- Condensation (1)
- Corrosion and storage (CCUS) technology (1)
- Crack tip opening displacement (1)
- Creep data (1)
- Creep-Fatigue (1)
- Crevice corrosion (1)
- Cross linking (1)
- Crystal plasticity (1)
- Cure process (1)
- Cyclic loading (1)
- Degradation (1)
- Dense phase (1)
- Dielectric properties (1)
- Digital material representation (1)
- Distributed fibre optic sensors (1)
- Distribution function (1)
- Droplet (1)
- Droplet corrosion (1)
- Dynamic mechanical analysis (DMA) (1)
- EBSD (1)
- EIS (1)
- Electrochemical dressing (1)
- Electropolishing (1)
- Epoxy (1)
- Fatigue of sandwich shell structures (1)
- Fe-Al alloys (1)
- Ferritic-martensitic steels (1)
- Ferroelectret (1)
- Fiber reinforced polymer (1)
- First year students (1)
- Flipped classroom (1)
- Fractography (1)
- Fracture (1)
- High - temperature corrosion (1)
- High alloyed steel (1)
- High alloyed steels (1)
- High cycle fatigue (1)
- High temperature corrosion (1)
- High temperature mechanical properties (1)
- Honing (1)
- Honing Stone (1)
- Hydrogen (1)
- IN718 (1)
- ISRU (1)
- Infrastructure (1)
- Injection (1)
- Intermetallics (1)
- Inverted classroom (1)
- Iron aluminides (1)
- Irregular topography (1)
- LTCC (1)
- Laminography (1)
- Laser Scanning Microscopy (1)
- Lecture videos (1)
- Lightweight materials (1)
- Long-term behavior (1)
- Low Cycle Fatigue (1)
- Lunar habitat (1)
- Machine Learning (1)
- Material degradation (1)
- Metal seal (1)
- Micromechanical model (1)
- Microstructure evolution (1)
- Microstructure-property-correlation (1)
- Monte-Carlo Simulation (1)
- Monte-Carlo-Analysis (1)
- Net zero (1)
- Neutron diffraction (1)
- Nickel based coatings (1)
- Non-destructive testing (1)
- Online teaching (1)
- Optical backscatter reflectometry (1)
- Optical fibre (1)
- Oxide scale (1)
- Paving (1)
- Photon counting detector (1)
- Pipelines (1)
- Pitting (1)
- Protective coating (1)
- Repair patch (1)
- Residual stress (1)
- Residual stresses (1)
- Rissausbreitung (1)
- Rotor blade (1)
- Roughness (1)
- S-phase (1)
- Sandwich (1)
- Scale-bridging (1)
- Scarf repairs (1)
- Selective laser melting (1)
- Self-healing (1)
- Sibayak (1)
- Silver nanoparticle (1)
- Sol-gel coating (1)
- Solar sintering (1)
- Starch (1)
- Starch nanoparticle (1)
- Storage (1)
- Structural health monitoring (SHM) (1)
- Surface (1)
- Swept wavelength interferometry (SWI) (1)
- Synchrotron Tomography (1)
- TEM (1)
- Temperature (1)
- Tensile data (1)
- Thermal Spray (1)
- Thermo-Mechanical Fatigue (1)
- Thermomechanics (1)
- Thermomechanische Ermüdung (1)
- Thermoplastic (1)
- Thermoset polymers (1)
- Transducers (1)
- Virtual experiments (1)
- Weibull Distribution (1)
- Wind energy (1)
- Wind turbine (1)
- X-ray laminography (1)
- laser cladding (1)
Organisationseinheit der BAM
- 5 Werkstofftechnik (54) (entfernen)
Common air-coupled transducers for non-destructive testing consist of a piezocomposite material and several matching layers. Better acoustical matching to air is achieved by transducers based on charged cellular polypropylene (PP). This material has about hundred times lower acoustic impedance than any piezocomposite, having about the same piezoelectric coefficient. The piezoelectric properties of cellular PP are caused by the polarization of air cells. Alternatively, a ferroelectret receiver can be understood as a capacitive microphone with internal polarization creating permanent internal voltage. The sensitivity of the receiver can be increased by applying additional bias voltage. We present an ultrasonic receiver based on cellular PP including a high-voltage module providing bias voltage up to 2 kV. The application of bias voltage increased the signal by 12 to 15 dB with only 1 dB increase of the noise.
This receiver was combined with a cellular PP transmitter in through transmission to inspect several test specimens consisting of glass-fiber-reinforced polymer face sheets and a porous closed-cell PVC core. These test specimens were inspected before and after load. Fatigue cracks in the porous PVC core and some fatigue damage in the face sheets were detected. These test specimens were originally developed to emulate a rotor blade segment of a wind power plant. Similar composite materials are used in lightweight aircrafts for the general aviation. The other inspected test specimen was a composite consisted of glass-fiber-reinforced polymer face sheets and a wooden core. The structure of the wooden core could be detected only with cellular PP transducers, while commercial air-coupled transducers lacked the necessary sensitivity. Measured on a 4-mm thick carbon-fiber-reinforced polymer plate, cellular PP transducers with additional bias voltage achieved a 32 dB higher signal-to-noise ratio than commercial air-coupled transducers.
The studied aluminium alloy is EN AW-2618A (2618A). It is very widely used for exhaust gas turbo-charger compressor wheels. Due to long operating times, high cycle fatigue (HCF) and material aging under the influence of temperatures up to 230 °C is particularly relevant for the wheels. The wheels are typically milled from round wrought blanks. From such round blanks, different testpieces are extracted and a comprehensive series of HCF tests is conducted at room temperature. The tests investigate the materials fatigue performance in the T61 state for two load-ratios, namely R = -1 and R = 0.1. Additionally, two overaged material states are tested, accounting for the aging process the material undergoes during long operating times at high temperatures. The experimental results are evaluated and compared to each other.
Furthermore, the design process of notched specimens is presented. With the notched specimens, it is aimed to quantify the notch sensitivity of the material. Relating thereto, two potential model parameters for the fatigue lifetime model are introduced. Finally, the extended research data management in this project is highlighted and its advantages for sustainable use in material science and engineering applications are shown.
The high operating temperatures of radial compressor wheels in exhaust gas turbochargers lead to a change in the original microstructure of the heat-resistant aluminum alloy EN AW-2618A (overaging). This is caused by thermal loads that are close to the age hardening temperature and can even exceed it for a short time. The aging mechanisms have been investigated together with low cycle fatigue (LCF), thermomechanical fatigue (TMF) and creep up to max. 190 °C in previous research projects. The be-havior of the alloy under high cycle fatigue (HCF) and the influence of load spectra have hardly been investigated. Since the operating temperatures of centrifugal compressors are expected to increase in the future, this research project investigated the HCF behavior at 230 °C, a test temperature significantly higher than the age hardening temperature. The objectives of the project were to establish a suitable experimental database, to understand the relevant microstructural processes, and to further develop and adapt suitable models and evaluation methods.
In addition to a basic characterization of the HCF behavior in the initial condition T61, the experimental investigation program included targeted mechanical tests to isolate the influencing factors of mean stress (𝑅=−1, 𝑅=0.1), material overaging (T61, 10 h/230 °C, 1000 h/230 °C), test temperature (20 °C, 230 °C), test frequency (0.2 Hz, 20 Hz) as well as variable amplitudes. On this basis, the models and evaluation methods developed in the previous projects were adapted and further developed to reflect thermal and mechanical loads in the lifetime assessment.
Additive Manufacturing (AM) of metals has become industrially viable for a large variety of applications, including aerospace, automotive and medicine. Powder bed techniques such as Selective Laser Melting (SLM) based on layer-by-layer deposition and laser melt enable numerous degrees of freedom for the geometrical design. Developing during the manufacturing process, residual stresses may limit the application of SLM parts by reducing the load bearing capacity as well as induce unwanted distortion depending on the boundary conditions specified in manufacturing.
The residual stress distribution in the bulk of IN718 elongated prisms produced by SLM was studied non-destructively by means of neutron diffraction. The samples with different scanning strategies, i.e. hatching length, were measured in as-build condition (on a build plate) and after removal from the build plate.
The absolute values of all stress components decreased after removal from the build plate. Together with surface scan utilizing a coordinate-measuring machine (CMM), it is possible to link the stress release to the sample distortion. Obtained results indicated different residual stress states for each of the transversal, longitudinal and normal component depending on the thermal gradient in the respective direction.
Glass-fibre-reinforced plastics (GFRP) are commonly used for the construction of pressure vessels and tanks for example in automotive and aerospace industries. Especially for pressure vessels used for the storage of natural gas or hydrogen with operation pressures up to 700 bar, an early material fatigue detection is of great interest. Measuring the distributed strain profile of GFRP structures helps to understand and detect material fatigue. In this article, we demonstrate the great potential of swept wavelength interferometry (SWI) based distributed strain sensing for the monitoring of pressure vessels made from GFRP. A resin transfer molding (RTM) process was used to manufacture GFRP-tube specimens. Commercial optical fibres with polyimid coating were glued to the surface externally in circumferential and axial direction. A cyclic load of up to 150 bar was applied to the samples using a servo-hydraulic test bench. Comparing the loaded and unloaded test conditions, we determined up to 2 % elongation in circumferential direction. We demonstrate reliable distributed strain measurements with sub-centimetre spatial resolution. By monitoring these high-resolution strain profiles, we were able to detect local material degradation that manifested itself as localized strain changes. Crucially, the material Degradation could be detected already after 75 % of dat the fatigue life before a crack appeared that led to leakage.
The commercial usage of latent thermal energy storages primarily depends on the development of a suitable phase change material (PCM). For industrial high temperature applications above 400 °C multicomponent chloride eutectics are promising and therefore discussed seriously. The profound thermodynamic investigation of such eutectics requires a much greater amount of specimen material than conventional calorimeter can handle. Therefore, a special adiabatic calorimeter was developed and designed. With a specimen mass of > 100 g the typical thermodynamic measurements with a commercial calorimeter can be extended by cycle stability measurements, which are often decisive for practical application of PCM. Furthermore, by implementing corrosion specimens inside the calorimeter high temperature corrosion experiments according to ISO 21608 can be performed inside the calorimeter. Adiabatic measuring conditions can be provided by using two separate heating systems. Therefore, the outer “protective system” follows the temperature curve of the inner “measuring system” minimizing the temperature difference between the heating systems and simultaneously preventing heat losses from the measuring systems.
This contribution provides current findings regarding materials susceptibility for carbon capture, utilization and storage (CCUS) applications. Basing on results gathered in 2 German long-term projects (COORAL and CLUSTER) suitable materials are introduced as well as dominating impurities of the CO2-stream and corrosion mechanisms. Investigations cover the whole CCUS process chain and provide material recommendations for certain parts.
In Germany spent nuclear fuel and high level radioactive waste is stored in interim storage containers with double lid systems. Those lids are equipped with metal seals (e.g. Helicoflex®) that ensure the safe enclosure of the inventory. The used metal seals consist of three components as can be seen in the cross-sectional view in Figure 1. The innermost part is a helical spring that is surrounded by an inner jacket made of stainless steel. The outer jacket that is made of a softer material which in case of assembly in the aforementioned storage containers is silver or aluminum (i.e. Al 99.5). During application the seal is compressed and due to the restoring force of the helical spring, the outer jacket is plastically deformed and adapts to the sealing surface. Hence, leakage paths are closed and the sealing function is generated. In Germany the above-mentioned containers are licensed for up to 40 years of interim storage, which in case extended storage becomes necessary before a final repository is available will have to be extended to even longer periods. Therefore, the evaluation of the long-term behavior of the seals is necessary, taking into account storage conditions, decay heat and possible mechanical loads as well.
At Bundesanstalt für Materialforschung und –prüfung (BAM) long-term investigations are being conducted in which seals are assembled in test flanges and aged at temperatures ranging from room temperature to 150°C for accelerated aging. The aged seals are tested semi-annually (after the first 6 months in which the seals are tested more frequently) regarding the sealing performance, the remaining seal force, and the useable resilience upon decompression. Results of these investigations have been published over the past years (e.g. Grelle, Wolff, Probst, Jaunich, & Völzke, 2017; Völzke, Wolff, Probst, Nagelschmidt, & Schulz, 2014). It was found that the seal force and the useable resilience decrease with time and temperature, which is in agreement with the result of other studies (Sassoulas et al., 2006; Wataru et al., 2016) as well. Geometry change of the outer jacket has been identified as the main reason for this seal behavior. At the prevailing operating temperatures and stresses the aluminum is subjected to creep deformation leading to a thinning of the outer jacket. Since the seal groove depth remains unchanged the helical spring expands, which in turn leads to a decrease of the generated spring and seal force.
Although the main reason for the change of seal parameters over time and temperature is known, a detailed characterization of the seal behavior and a reliable prediction of the parameter development for aging times that exceed the experimental time frame have not been possible, yet.
For deeper understanding of the aging processes, an Investigation program, which is covered in this contribution, is conducted at Bundesanstalt für Materialforschung und –prüfung (BAM) that focusses on the behavior of the aluminum jacket and its influence on the long-term sealing performance. The program investigates properties of material samples as well as the behavior of the seal as a component.
Original sheet material of the same aluminum that is used for manufacturing of the seals is investigated in compression creep tests. For this, a DMA (dynamic mechanical analysis) machine is employed (here used for static tests) that allows for a measurement of the specimens deformation under forces of up to 500 N. The advantage of this method is that the original material can be tested in the same shape as used for the seals which is 0.5 mm thick sheet material. For investigation of tensile creep standard specimens are used, that were machined from surrogate material of the same composition and annealing condition.
Furthermore, aluminum seals that are cut into smaller segments are assembled in flanges and placed in heating chambers at temperatures ranging from 23°C to 150°C. After different periods of time from 3 days to 300 days the segments are taken out of the flanges and are investigated, thus giving information on different states of aging. Measurements of the development of the seal contact width and the aluminum jacket thickness are done with an optical microscope. Further investigations on the segments will include metallography and hardness measurements.
From the detailed material and component behavior including the results of the long-term seal force and useable resilience investigations a better understanding of the overall seal behavior can be gained. The aim is to contribute to the development of material models and analytical approaches for the prediction of the sealing behavior in dependence of time and temperature.
Cyclic fatigue behavior of glass fiber reinforced epoxy resin at ambient and elevated temperatures
(2018)
The fatigue behavior of ±45° glass fiber reinforced epoxy resin under cyclic mechanical and constant thermal loading is investigated in this study. Tests at three different temperature levels in the range 296 K to 343 K have been performed in order to create S-N curves for each temperature level. The specimen damage is measured in-situ using optical grayscale analysis. The characteristic damage state (CDS) is evaluated for each specimen. It is shown that the point of CDS is suitable as a failure criterion to compare the resulting S-N curves. With micromechanical formulations, the temperature-dependent matrix effort is calculated for each stress-temperature level. In terms of matrix effort, the longest fatigue life is reached at high temperatures, while, in terms of stress, the lowest fatigue life is reached at the highest temperatures.