Investigation of the Thermal Stability of Proteinase K for the Melt Processing of Poly(L‑lactide)
(2022)
The enzymatic degradation of aliphatic polyesters offers unique opportunities for various use cases in materials science. Although evidently desirable, the implementation of enzymes in technical applications of polyesters is generally challenging due to the thermal lability of enzymes. To prospectively overcome this intrinsic limitation, we here explored the thermal stability of proteinase K at conditions applicable for polymer melt processing, given that this hydrolytic enzyme is well established for its ability to degrade poly(L-lactide) (PLLA). Using assorted spectroscopic methods and enzymatic assays, we investigated the effects of high temperatures on the structure and specific activity of proteinase K. Whereas in solution, irreversible unfolding occurred at temperatures above 75−80 °C, in the dry, bulk state, proteinase K withstood prolonged incubation at elevated temperatures. Unexpectedly little activity loss occurred during incubation at up to 130 °C, and intermediate levels of catalytic activity were preserved at up to 150 °C. The resistance of bulk proteinase K to thermal treatment was slightly enhanced by absorption into polyacrylamide (PAM) particles. Under these conditions, after 5 min at a temperature of 200 °C, which is required for the melt processing of PLLA, proteinase K was not completely denatured but retained around 2% enzymatic activity. Our findings reveal that the thermal processing of proteinase K in the dry state is principally feasible, but equally, they also identify needs and prospects for improvement. The experimental pipeline we establish for proteinase K analysis stands to benefit efforts directed to this end. More broadly, our work sheds light on enzymatically degradable polymers and the thermal processing of enzymes, which are of increasing economical and societal relevance.
The complex nature of liquid water saturation of polymer electrolyte fuel cell (PEFC) catalyst layers (CLs) greatly affects the device performance. To investigate this problem, we present a method to quantify the presence of liquid water in a PEFC CL using small-angle X-ray scattering (SAXS). This method leverages the differences in electron densities between the solid catalyst matrix and the liquid water filled pores of the CL under both dry and wet conditions. This approach is validated using ex situ wetting experiments, which aid the study of the transient saturation of a CL in a flow cell configuration in situ. The azimuthally integrated scattering data are fitted using 3D morphology models of the CL under dry conditions. Different wetting scenarios are realized in silico, and the corresponding SAXS data are numerically simulated by a direct 3D Fourier transformation. The simulated SAXS profiles of the different wetting scenarios are used to interpret the measured SAXS data which allows the derivation of the most probable wetting mechanism within a flow cell electrode.
The first international round-robin exercise for the measurement of the long-lived radionuclide 10Be has been conducted. Ten participating accelerator mass spectrometry (AMS) facilities have each measured three samples at the 10-12 to 10-14 10Be/9Be level. All results have been made traceable to the NIST SRM 4325 standard to avoid additional discrepancies that arise when different facilities use different calibration materials. Hence, the data concentrates on pure measurement distinctions. Multivariate statistical investigations have been performed to reveal a bias between facilities, i.e. two distinguished groups could be identified. Maximum discrepancies between two single facilities are in the range of 6–31% depending on the absolute 10Be/9Be value. These findings should be considered when comparing 10Be data produced at one AMS facility with that produced at another facility, which is e.g. often the case for in situ 10Be dating studies. Round-robin exercises are a very helpful tool as part of an overall quality assurance scheme to improve the accuracy, and not only the precision, of AMS data.
A first international 36Cl interlaboratory comparison has been initiated. Evaluation of the final results of the eight participating accelerator mass spectrometry (AMS) laboratories on three synthetic AgCl samples with 36Cl/Cl ratios at the 10-11, 10-12, and 10-13 level shows no difference in the sense of simple statistical significance.
However, more detailed statistical analyses demonstrate certain interlaboratory bias and underestimation of uncertainties by some laboratories. Following subsequent remeasurement and reanalysis of the data from some AMS facilities, the round-robin data indicate that 36Cl/Cl data from two individual AMS laboratories can differ by up to
17%. Thus, the demand for further work on harmonising the 36Cl-system on a worldwide scale and enlarging the improvement of measurements is obvious.