Filtern
Dokumenttyp
Schlagworte
- 3D-Geoinformation (1)
- Active-Site Quantification (1)
- Additive manufacturing (1)
- Bioactive glass scaffold (1)
- Biosensing (1)
- Bone marrow-derived mesenchymal stem cell (1)
- Building model (1)
- CEA (1)
- City model (1)
- CityGML (1)
Organisationseinheit der BAM
- 2 Prozess- und Anlagensicherheit (4)
- 2.1 Sicherheit von Energieträgern (4)
- 8 Zerstörungsfreie Prüfung (2)
- 8.5 Röntgenbildgebung (2)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.2 Biophotonik (1)
- 3 Gefahrgutumschließungen; Energiespeicher (1)
- 3.6 Elektrochemische Energiematerialien (1)
- 5 Werkstofftechnik (1)
- 5.4 Multimateriale Fertigungsprozesse (1)
The space heating system accounts for 20%~50% of building energy consumption, and may lead to energy waste due to unreasonable controls. In this study, an energy-efficient floor heating system with intelligent control was proposed to improve energy efficiency of the system. In order to validate the concept of the proposed intelligent control, an experimental system was designed and constructed in Chengdu, China. Temperature, control cycle and energy consumption were then studied under different control strategies. The result shows that a larger flow rate of supply water will result in a longer control cycle and a lower control frequency, i.e., the average control cycle at 7 L min−1 is 1.7 h during the test day, while it is 1.5 h at 5 L min−1. Moreover, adopting water with a higher temperature and flow rate could achieve a higher efficiency of the system. The energy consumptions in case 1 (5 L min−1, 50 °C), case 2 (5 L min−1, 55 °C), case 5 (7 L min−1, 55 °C) and case 6 (7 L min−1, 60 °C) are 4746 kJ, 3534 kJ, 3093 kJ and 3028 kJ, respectively. Based on the experimental data, the supply water temperature is suggested to set lower than 60 °C considering human comfort.
Thermoelectric generator (TEG) has been proved as a promising technology for directly converting heat into electricity based on Seebeck effect. On the contrary, this electricity can trigger a solid-state cooling based on conventional Peltier effect. However, these two effects induce a coupling between heat and electric flux, especially for the quantitative relationship still remaining a mystery. Here, we show experimental evidence and theoretical calculation for the coupling by monitoring transient response of fluid temperature and output power. The experimental maximum heat flow in open circuit is 1162 W at cold fluid flow rate = 0.3 m3/h and fluid temperature difference ΔTf = 70 °C, enhanced by 13% owing to heat compensation from intrinsic coupling in closed-loop circuit. Meanwhile, the measured maximum output power of TEG is 18.2 W, and subsequently decreases to 15.4 W due to the objective existence of coupling. This double-edged sword in coupling vigorously inspires the potential applications in heat-dissipation situation such as spacecraft, electronic components, photovoltaic, refrigerator and etc. Present findings open a novel avenue for manipulating heat-electricity conversion in practical engineering.
This article is an outcome of a workshop on Fatigue of Additive Manufactured Metallic Components jointly organized by the Federal Institute for Materials Research and Testing (BAM) Berlin, Germany and the National Institute of Standards and Technology (NIST) Boulder, CO, U.S.A. The aim of the workshop was a comprehensive discussion of the specific aspects of additively manufactured (AM) components in regard to failure under cyclic loading. Undoubtedly, a better understanding and the further development of approaches for damage tolerant component design of AM parts are among the most significant challenges currently facing the use of these new technologies.
This article presents a thorough overview of the workshop discussions. It aims to provide a review of the parameters affecting the damage tolerance of AM parts with special emphasis on the process parameters intrinsic to the AM technologies, the resulting defects and residual stresses. Based on these aspects, concepts for damage tolerant component design for AM are reviewed and critically discussed.
Mononuclear Fe ions ligated by nitrogen (FeNx) dispersed on nitrogen-doped carbon (Fe-N-C) serve as active centers for electrocatalytic O2 reduction and thermocatalytic aerobic oxidations. Despite their promise as replacements for precious metals in a variety of practical applications, such as fuel cells, the discovery of new Fe-N-C catalysts has relied primarily on empirical approaches. In this context, the development of quantitative structure−reactivity relationships and benchmarking of catalysts prepared by different synthetic routes and by different laboratories would be facilitated by the broader adoption of methods to quantify atomically dispersed FeNx active centers. In this study, we develop a kinetic probe reaction method that uses the aerobic oxidation of a model hydroquinone substrate to quantify
the density of FeNx centers in Fe-N-C catalysts. The kinetic method is compared with low-temperature Mössbauer spectroscopy, CO pulse chemisorption, and electrochemical reductive stripping of NO derived from NO2 − on a suite of Fe-N-C catalysts prepared by diverse routes and featuring either the exclusive presence of Fe as FeNx sites or the coexistence of aggregated Fe species in addition to FeNx. The FeNx site densities derived from the kinetic method correlate well with those obtained from CO pulse chemisorption and Mössbauer spectroscopy. The broad survey of Fe-N-C materials also reveals the presence of outliers and challenges associated with each site quantification approach. The kinetic method developed here does not require pretreatments that may alter active-site distributions or specialized equipment beyond reaction vessels and standard analytical instrumentation.
Time-gated Förster resonance energy transfer (TG-FRET) between Tb complexes and luminescent semiconductor quantum dots (QDs) provides highly advantageous photophysical properties for multiplexed biosensing. Multiplexed Tb-to-QD FRET immunoassays possess a large potential for in vitro diagnostics, but their performance is often insufficient for their application under clinical conditions. Here, we developed a homogeneous TG-FRET immunoassay for the quantification of carcinoembryonic antigen (CEA), neuron-specific enolase (NSE), and prostatespecific antigen (PSA) from a single serum sample by multiplexed Tb-to-QD FRET. Tb–IgG antibody donor conjugates were combined with compact QD-F(ab’)2 antibody acceptor conjugates with three different QDs emitting at 605, 650, and 705 nm. Upon antibody–antigen–antibody Sandwich complex formation, the QD acceptors were sensitized via FRET from Tb, and the FRET ratios of QD and Tb TG luminescence intensities increased specifically with increasing antigen concentrations.
Although limits of detection (LoDs: 3.6 ng/mL CEA, 3.5 ng/mL NSE, and 0.3 ng/mL PSA) for the triplexed assay were slightly higher compared to the single-antigen assays, they were still in a clinically relevant concentration range and could be quantified in 50 μL serum samples on a B·R·A·H·M·S KRYPTOR Compact PLUS clinical immunoassay plate reader. The simultaneous quantification of CEA, NSE, and PSA at different concentrations from the same serum sample demonstrated actual multiplexing Tb-to-QD FRET immunoassays and the potential of this technology for translation into clinical diagnostics.
Image-guided, targeted and triggered drug delivery to tumors using polymer-based microbubbles
(2012)
Microbubbles (MB) are routinely used contrast agents for functional and molecular ultrasound (US) imaging. In addition, they have been attracting more and more attention for drug delivery purposes, enabling e.g. US-mediated drug delivery across biological barriers and US-induced triggered drug release from the MB shell. The vast majority of efforts in this regard have thus far focused on phospholipid-based soft-shell MB, which are suboptimal for stably incorporating large amounts of drug molecules because of their relatively thin shell. Using poly(butyl cyanoacrylate) (PBCA)-based hard-shell MB, we show here that both hydrophilic (Rhodamine-B) and hydrophobic (Coumarin-6) model drugs can be efficiently and stably entrapped within the ~ 50 nm shell of PBCA MB. In addition, we demonstrate that model drug loading does not negatively affect the acoustic properties of the MB, and that functionalizing the surface of fluorophore-loaded MB with anti-VEGFR2 antibodies enables image-guided and targeted model drug delivery to tumor blood vessels. Finally, we show both in vitro and in vivo that disintegrating VEGFR2-targeted MB with high-mechanical index US pulses leads to high levels of model drug release. Consequently, these findings indicate that polymer-based MB are highly suitable systems for image-guided, targeted and triggered drug delivery to tumors and tumor blood vessels.
Self-sustaining smoldering as a novel disposal approach for food waste with high moisture content
(2021)
This work aims to explore the self-sustaining smoldering treatment (SSST) for the destruction of food waste. The food waste used in this work mainly consists of cereal, vegetable, and meat. To examine the processing procedures and parameters, three experimental groups (raw food waste, food-waste paste and food-waste paste blended with anthracite) and five variables (moisture content, sand size, sand-to-food waste ratio, air flow and food waste-to-coal ratio) were extensively investigated. Results show that raw food waste with 40% moisture content can be disposed by SSST with the mass destruction ratio over 90%. However, the robustness of SSST for raw food waste is constrained by the heterogeneous issue due to a variety of components and sizes of food waste. This issue is addressed through stir pre-processing of raw food waste as food-waste paste. The robustness of SSST for food waste is significantly further enhanced only if a slight mass fraction of anthracite (<20% of raw food waste) is supplemented. This provides an alternative solution for employing SSST for raw food waste with very high moisture content.
The mechanical compression of metal foam flow-field based polymer electrolyte fuel cells (PEFCs) is critical in determining the interfacial contact resistance with gas diffusion layers (GDLs), reactant flow and water management.
The distinct scale between the pore structure of metal foams and the entire flow-field warrant a multilength scale characterization that combines ex-situ tests of compressed metal foam samples and in-operando analysis of operating PEFCs using X-ray computed tomography (CT) and neutron radiography. An optimal ‘medium’ compression was found to deliver a peak power density of 853 mW/cm². The X-ray CT data indicates that the compression process significantly decreases the mean pore size and narrows the pore size distribution of metal foams. Simulation results suggest compressing metal foam increases the pressure drop and gas velocity, improving the convective liquid water removal. This is in agreement with the neutron imaging results that demonstrates an increase in the mass of accumulated liquid water with minimum compression compared to the medium and maximum compression cases. The results show that a balance between Ohmic resistance, water removal capacity and parasitic power is imperative for the optimal performance of metal foam based PEFCs.
To reveal and improve our understanding of the ignition behavior and mechanism, G-G furnace experiments of three typical organic dusts were performed to investigate the minimum ignition temperature (MIT) in O2/N2, O2/ Ar and O2/CO2 atmospheres with oxygen mole fraction from 8.4% to 50%. The experimental results were presented in oxygen-lean and oxy-fuel atmospheres to evaluate the ignition sensitivity of dusts in different atmospheres. It was found that CO2 is the strongest in terms of lowing the ignition sensitivity of the three dusts, and the dust explosion risk increases significantly with increasing O2 mole fraction for the three dusts through a logarithmically and significantly reducing MIT. However, for different dusts, inert gases show different suppression effects. In addition, a modified steady-state homogeneous ignition model was proposed and successfully applied to oxygen-lean atmospheres, and in oxy-fuel atmospheres, this model has also been improved to estimate the ignition mechanism. This ignition mechanism model could be used to successfully predict the minimum ignition temperature of high volatile dust under different inert atmospheres controlled by homogeneous ignition, which will provide a reference for the ignition hazard assessment of dust on hot surfaces.
Die Verwendung offener Standards bietet eine Vielzahl von Möglichkeiten, gerade im Bereich des Datenaustausches, Datenlagerung, aber auch der Interoperabilität. GML und CityGML sind hervorragende Beispiele für die Beschreibung von Realweltobjekten mittels eines offenen Standards wohingegen SensorML dazu dient, Messungen, Sensoren und Messplattformen zu beschreiben. Die Verwendung solcher Standards eröffnet dem Nutzer nicht nur die Möglichkeiten der Verwendung einer gemeinsamen standardisierten Sprache, sondern auch die Nutzung von offenen Servicestandards, wie Web Feature Service (WFS), Web Map Service (WMS) oder von Sensor Observation Services (SOS).
Die Kombination von Geodaten- und Sensorstandards in einer Dienste- und Servicearchitektur geht über bisherige am Markt existierende Lösungen hinaus und schafft eine neuartige Plattform für die Bauwerksüberwachung, die weit mehr als ein simples Datenhaltungsmodell darstellt. Die in diesem Beitrag vorgestellte Plattform ermöglicht eine direkte Integration von Sensordaten sowie deren Bereitstellung durch eine offene Standardsprache. Dabei sind alle Zwischenschritte jederzeit über eine offene Diensteschnittstelle adressierbar und können so verschiedenen Akteuren zur Verfügung gestellt werden. Das große Potential und der Mehrwert eines derartigen Informationssystems liegt vor allem in der permanenten Verfüg-barkeit von Mess- und Objektdaten und einer damit verbundenen integrierten Analyse der Sensormessdaten in Kombination mit einem Finite-Elemente-Modell (FEM), basierend auf den Objektdaten. Die automatische Ableitung eines FE-Modells aus dem 3D-Bauwerks-modell, die Visualisierung der FEM-Simulationsergebnisse anhand des Bauwerksmodells, die Bereitstellung von Messrohdaten und Sensorinformationen zu jedem Messzeitpunkt machen die Plattform zu einem universell einsetzbaren Werkzeug im Bereich der Bauwerksüberwachung. In diesem Beitrag werden die einzelnen Bausteine, die verwendeten Standards und die Interaktion der einzelnen Komponenten zu einem Gesamtsystem vorgestellt.