A comprehensive characterization of plasma modified polymer surfaces or plasma-polymerized thin films needs access to parameters as
- concentration of saturated/unsaturated carbon species (e.g. aromaticity) or other double bonds as C=N or C=O,
- branching, and
- losses of crystallinty or other degrees of structural order.
Furthermore the complex ageing phenomena of plasma modified polymers/plasma-polymers and the measurement of an in-depth distribution of chemical species are challenges for the analyst. The talk will display selected examples where such challenges have been met by using advanced methods of surface chemical analyses as Photoelectron Spectroscopy with variable excitation energy (“SyncXPS”), X-ray Absorption Spectroscopy (NEXAFS) at C, N and O K-edges and Time-of-Flight Secondary Mass Spectroscopy (ToF-SIMS) combined with Principal Component analysis (PCA).
Safe innovation & sustainable production with MNMs need that we:
Understand risks and benefits (diagnostic, assessment)
Identify and implement risk reduction strategies (manage)
Communicate on residual risks (acceptance)
Huge knowledge on characterization, hazards, diagnostic (science)
Little effective use of it for operational risk management (expertise)
Objectives of the centre:
Bridge the gap between research and application (public, private),
Bridge the gap between knowledge on risks and risk management,
Balance between Science and Appliance,
in a sustainable way:
Efficient & Sustainable structure
Collective, harmonized, shared expertise
EU scale, internationally connected.
Reference-free XRF is a SI traceable technique for the
determination of the mass deposition (mass per unit area) of elements in films on the nano- and micro scale. The method is radiometrically calibrated instrumentation (PTB@BESSY II, Germany) and based on reliable knowledge of all relevant atomic fundamental, experimental and instrumental parameters. No calibration sample or reference materials are necessary. The approach had been validated in the CCQM-P140 pilot study and the K129 key comparison by determination of mole fractions in Cu(In,Ga)Se2 thin films.
The certified reference material BAM-L200, a nanoscale stripe pattern for length calibration and specification of lateral resolution, is described. BAM-L200 is prepared from a cross-sectioned epitaxially grown layer stack of AlxGa1-xAs and InxGa1 xAs on a GaAs substrate. The surface of BAM-L200 provides a flat pattern with stripe widths ranging down to 1 nm. Calibration distances, grating periods and stripe widths have been certified by TEM with traceability to the length unit. The combination of gratings, isolated narrow stripes and sharp edges of wide stripes offers a plenty of options for the determination of lateral resolution, sharpness and calibration of length scale at selected settings of imaging surface analytical instruments. The feasibility of the reference material for an analysis of the lateral resolution is demonstrated in detail by evaluation of ToF-SIMS, AES and EDX images. Other applications developed in the community are summarized, too.
BAM-L200 fully supports the implementation of the revised International Standard ISO 18516 (in preparation) which is based on knowledge outlined in the Technical Report ISO/TR 19319:2013.
As a chemical metrology tool time-of-flight secondary ion mass spectrometry (ToF-SIMS) has become a very popular technique to monitor the elemental, isotopic and molecular distribution in two or three dimensions. Its reduced sampling depth, high sensitivity, great structural specificity and the direct detection of hydrogen thereby increase the emergence of ToF-SIMS for material and analytical surface science, particularly due to recent instrumental developments improving mass, depth and lateral resolution. For basic surface science, adsorption processes and surface reactivity thus can be investigated in high detail on organic as well as inorganic samples. The use of multivariate data analysis in addition can effectively assist to identify trends in the complex SIMS raw data set and define key co-variances between certain samples or mass spectra. In this contribution the essence of ToF-SIMS is illustrated by discussing two highly relevant energy applications. First, for piezoelectric electroceramics oxygen exchange active zones have been visualized to determine the impact of external field-load to the oxygen vacancy distribution between anode and cathode. As a second case study the interaction of hydrogen species with the microstructure of a duplex stainless steel was investigated. It was concluded that ToF-SIMS has a valuable essence for detailing hydrogen related degradation mechanisms.
Graphene prepared from Graphene oxide (GO) is used as a platform for functional 2D nanomaterials with diverse applications ranging from bios ensors to antimicrobial surfaces. C and N K-edge NEXAFS and XPS spectroscopies at BESSY’s HE-SGM beamline have been used to prove and control covalent functionalization of graphenic materials at ambient conditions for the synthesis of functional 2D-surfaces.
The project addresses chemical and topographical metrology at surfaces. The new methodologies of measurements at surfaces will be developed as good practice guides and new work item proposals for industrial ISO standards. The objectives of the Joint research project (JRP) are to provide measurement standards and methods with traceability wherever it is practicable to do so for quantitative surface chemical analysis for industrial applications.
Deuterium permeation and cracking in duplex steels as viewed by ToF-SIMS and HR-SEM with data fusion
(2016)
Better understanding of hydrogen assisted degradation and trapping mecha-nisms requires sufficient imaging techniques for respective hydrogen-microstructure interaction studies, in particular with multi-phase metallic micro-structures [1]. The present work is focusing on the elucidation of deuterium be-havior in two austenitic-ferritic duplex stainless steels (DSS) under the assumption that deuterium behaves in many ways similarly to hydrogen [2]. For case studies standard 2205 and lean 2101 DSSs were chosen due to the extensive use of these steels in industry [3]. The analyses were conducted by using a novel in-situ permeation and Time-of-Flight secondary ion mass spectrometry (ToF-SIMS) imaging technique or by ex-situ ToF-SIMS imaging following electrochemical charging experiments. Another pioneering procedure was data fusion (including chemometry) of results of powerful laterally resolved chemical analysis and high resolution structural characterization techniques .
Results for the ex-situ observations showed a different influence of deuterium loading on the two steel grades as well as different damage mechanisms in each phase. Formation of sub-surface blisters between the ferrite and austenite were obtained in both the standard and the lean DSS. In both steels, an increased deuterium concentration was observed around deformed regions such as cracks, confirming that they originate from the presence of deuterium [4]. The formation of parallel cracks was obtained only in the austenite within the standard duplex whereas in the lean duplex the highest intensity of deuterium was obtained in the austenite along the ferrite-austenite interphase.
In comparison, application of the novel in-situ permeation technique enabled to register and record the deuterium permeation through the material and the respective saturation sequence of the two phases as well as the interfaces. Faster diffusion of the deuterium was observed in the ferrite and a direct proof for deuterium enrichment at the austenite-ferrite interface has been given [1]. The integration of the specified techniques gives a better insight into the processes leading to hydrogen induced failure. These two experimental techniques provide very valuable tools for elucidation of respective metallurgical failure mechanisms that can be used for the validation of respective numerical models for hydrogen assisted cracking (HAC).
The certified reference material BAM-L200, a nanoscale stripe pattern for length calibration and specification of lateral resolution, is described. BAM-L200 is prepared from a cross-sectioned epitaxially grown layer stack of AlxGa1-xAs and InxGa1-xAs on a GaAs substrate. The surface of BAM-L200 provides a flat pattern with stripe widths ranging down to 1 nm. Calibration distances, grating periods and stripe widths have been certified by TEM with traceability to the length unit. The combination of gratings, isolated narrow stripes and sharp edges of wide stripes offers a plenty of options for the determination of lateral resolution, sharpness and calibration of length scale at selected settings of imaging surface analytical instruments. The feasibility of the reference material for an analysis of the lateral resolution is demonstrated in detail by evaluation of ToF-SIMS, AES and EDX images. Other applications developed in the community are summarized, too.
BAM-L200 fully supports the implementation of the revised International Standard ISO 18516 (in preparation) which is based on knowledge outlined in the Technical Report ISO/TR 19319:2013. Fundamental approaches to determination of lateral resolution and sharpness in beam-based methods
Materials and chemical producers require detailed knowledge of surface chemistry for research into new products. One way to understand a surface without damaging it is to bombard it with an electron beam, causing its atoms to emit characteristic X-rays enabling identification. The measurement of these must be precise as many elements emissions are close in energy – traceable reference materials will ensure instruments using this technique are stable and accurate.