The concreting of prefabricated concrete structures can lead to insufficient bonding or even to remaining cavities. Honeycombs (aggregate clusters without cement) represent potential weakening of the structure and need to be detected non-destructively. In our study we tested the capability of ground penetrating radar (GPR)techniques for this purpose. We applied GPR in reflection mode and zero-offset profiling (ZOP) Transmission mode on a precast concrete twin wall with built-in honeycombs. GPR measurements were performed as twochannel measurement with ground coupled antennas with centre frequencies of 1.5 GHz and 2.6 GHz mounted to an automated scanner system.
Our findings show that ZOP transmission measurements are a more efficient method to detect voids in reinforced concrete structures compared to reflection mode measurements. This holds for both the effort needed for the measurement and the evaluation as well as the validity of the data. Honeycombs (basically representing voids) are usually characterized by strongly reduced amplitudes and earlier arrivals of the transmitted wave.
Amplitudes variation of GPR rebar reflection due to the influence of concrete aggregate scattering
(2015)
Dense GPR measurements of rebar reflection amplitudes Show relative variations, which can be in the order of more than 10% - 20%. Former investigations demonstrated that these variations are caused by the heterogeneity of concrete, i.e. due to the inclusion of aggregates in concrete. These amplitude variations make it difficult to analyse single reflection amplitudes in order to determine the rebar diameter or to estimate the concrete deterioration state. In a systematic study we have quantified the statistical variation of the rebar reflection amplitude for concrete covers of 6 cm, 9 cm, 12 cm, 15 cm and 18 cm, for two different grading curves and for the rebar diameters 12 mm and 28 mm. Also the influence of the wavelength has been investigated by using antennas with different centre frequencies in relation to the aggregate size. The results are discussed with regard to a quantitative amplitude evaluation of GPR measurements and also the potential of using these variations for a characterization of concrete material properties.