Load attachment points, consisting of the lifting component and corresponding bolt connections, and lid systems, consisting of a lid, gaskets and bolt connections, are usually analyzed numerically using the Finite Element Method. Reasons for applying the FEM are complex geometry, specific load distribution and the violation of application criteria for analytical approaches. For example the elementary beam theory is not suitable for the calculation of compact trunnions and the Kirchhoff plate theory is not suitable for the calculation of lids with a large thickness to diameter ratio because the Bernoulli-hypothesis is violated. In addition for structural integrity assessments often local stress and for the evaluation of lid systems tightness local contact opening are needed, which can be obtained only through accurately discretized numerical models.
Independent comparative calculations are essential for complex calculations. Simplified but appropriate analytical approaches are an efficient way of examination. Is it possible to provide conservative analytical estimates of such kind of analysis problems? Are analytical calculations an appropriate approach in today's authority assessment business? Using the example of bolted trunnion and lid systems of a heavy package the possibilities and limits of analytical comparative calculations are shown.
Ziel dieses Beitrages soll es sein, zum einen das Vorgehen bei der Erlangung einer Anerkennung zur qualitätsgesicherten Herstellung einer Verpackung für prüfpflichtige Versandstücke der zuständigen Behörde im Sinne des ADR Unterabschnittes 1.7.3 darzustellen und zum anderen Probleme bei der Umsetzung der rechtsverbindlichen Vorschriften des Gefahrgutrechts aufzuzeigen.
Assessment experience on packages loaded with damaged spent nuclear fuel for transport after storage
(2018)
In 2017 the first German package approval certificate was issued for a dual purpose cask (DPC) design with encapsulated damaged spent nuclear fuel. At the Bundesanstalt für Materialforschung und -prüfung (BAM) a comprehensive assessment procedure was carried out with respect to the mechanical and thermal design, the containment design and quality assurance for manufacturing and operation. Main objective of this procedure was to verify the Package Design Safety Report (PDSR) fulfils the requirements according to the IAEA regulations SSR-6.
Until now only standard spent nuclear fuel assemblies were designated for interim storage and transports. Due to nuclear phase out in Germany all other kinds of SNF in particular damaged fuel has to be packed. Therefore specific requirements have to be considered in accordance with international experiences written in IAEA technical reports. In Germany damaged spent nuclear fuel (DSNF) needs a tight encapsulation with special encapsulations and clearly defined properties.
Due to the limited amount of DSNF these encapsulations are designed for storage and transport in existing packages. From the assessment experience it has been seen, corresponding PDSR need an extensively expansion to cover the design of these encapsulations and their influences on the package. Then such well-defined encapsulations can be handled like standard fuel assemblies. The main difference to standard package components is, encapsulations with permanent closure achieve their specified condition not after manufacturing but only during operation after loading and closing.
Thus specific handling instruction and test procedures are necessary especially for welding, where BAM is able to survey the quality of this first part of operation.
In the approval procedure of transport packages for radioactive materials, the mechanical and thermal safety assessment is carried out in Germany by competent authority BAM. In recent years BAM was involved in several licensing procedures of new spent fuel and HLW package designs, where the cask body was made of Ductile Cast Iron (DCI). According to IAEA regulations package designs have to fulfill requirements for specific conditions of transport. Type B(U) packages must withstand the defined accident conditions of transport. The temperature range from -40°C up to the operational temperature has to be considered. For the cask material DCI, it is necessary to determine the brittle fracture behavior. The German guideline BAM-GGR 007 defines requirements for the fracture mechanics of DCI. Due to complex structure of the cask body and the dynamic loading a fracture mechanical assessment in an analytical kind is not always possible. Experience of recent design approval procedures show that the application of numerical calculations are applicable to determine the fracture mechanical load in the cask body. At the first step a numerical analysis has to be done to identify the loading state at the whole cask body. Secondly an analysis of a detail of the cask body is made considering the displacement boundary conditions of the global model. An artificial flaw is considered in this detailed model to calculate the fracture mechanical loading state. The finite element mesh was strongly refined in the area of flaw. The size of the artificial flaw is characterized by the ultrasonic inspection used for the quality assurance of the package. The applicant developed additional analysis tools for calculation of stress intensity factor and/or J-Integral. The assessment approach by BAM led to the decision to develop own tools to the possibility for independent check of the results.
The paper describes the authority assessment approach for the DCI fracture mechanics analysis. The validation procedure incl. the development of own tools is explained. BAM developed a post-processor called JINFEM to determine the fracture mechanical loads. The regulatory 1 m puncture bar drop test is used to give an example of the assessment procedure.