Filtern
Dokumenttyp
Schlagworte
- Offshore wind turbines (5)
- Integrated monitoring system (4)
- Data management (3)
- Integrated Monitoring System (3)
- Structural assessment (3)
- Assessment (2)
- Automated operational modal analysis (2)
- Damage Identification (2)
- Damage detection (2)
- Damage identification (2)
- Limit values (2)
- Load Monitoring (2)
- Load monitoring (2)
- Resonance (2)
- Rotor blades (2)
- Sommerfeld effect (2)
- Structural health monitoring (2)
- Vibration (2)
- Wind turbine (2)
- Wind turbines (2)
- Bewertung (1)
- Damage indicators (1)
- Data analysis (1)
- Design verification (1)
- Dynamic analysis (1)
- Dynamic loads (1)
- Embedded FBG sensors (1)
- Embedded sensors (1)
- Environmental/operational effects (1)
- Ermüdung (1)
- Load transfer (1)
- Measurement hardware (1)
- Modal properties (1)
- Monitoring (1)
- Novelty analysis (1)
- Offshore-Windenergie (1)
- Principal Component Analysis (1)
- Risk (1)
- Robustness (1)
- Schadensindikatoren (1)
- Structural reliability (1)
- Strukturspannungskonzept (1)
- Wind energy converter (1)
- Zuverlässigkeit (1)
Eingeladener Vortrag
- nein (1)
Das Bauwerk einer Windenergieanlage dient der Sicherstellung der Energieproduktion. Eine entsprechende Zuverlässigkeit der Struktur und deren permanente Bewertung und Unterhaltung ist dazu notwendig. In diesem Beitrag werden Möglichkeiten der Bewertung des für die Struktur wichtigen Schädigungsmechanismus Ermüdung sowie dessen Überwachung in Zusammenhang mit Schädigungsindikatoren aufgezeigt. Dabei wird auf strukturmechanische, werkstoffmechanische und probabilistische Modelle sowie auf Messdaten eines Prototyps einer OWEA zurückgegriffen. Ausgehend von der gesamtdynamischen Berechnung wird die Zuverlässigkeit gemäß der Auslegung für den Schädigungsmechanismus Ermüdung durch ein Wöhlerlinienmodell berechnet. Damit werden ermüdungssensible Komponenten der Struktur identifiziert. Schädigungsindikatoren zur Überwachung der Ermüdungsfestigkeit werden auf Grundlage schädigungs-äquivalenter Dehnungen vorgestellt.
Fatigue assessment of support structures for offshore wind energy converters.
The structure of wind energy converters secures a reliable energy production. Hence an adequate reliability of the structure and additionally permanent assessment and maintenance is required. Within this paper methods for the assessment of the important damage mechanism fatigue in combination with monitoring of the fatigue reliability utilizing damage indicators are proposed. These methods comprise structural system, material degradation and probabilistic models as well as monitoring data of an offshore wind energy converter prototype. The structural reliability of the structure as designed is calculated based on an overall dynamic analysis using a SN-approach. Herewith fatigue sensitive components are identified. Damage indicators for monitoring the fatigue reliability based on damage equivalent strains are presented.
The concept and technical details of the implementation of the developed integrated monitoring system within the IMO-WIND project are presented. The tasks of the components of the system and its requirements are described. Selected results from the continuous monitoring during operation of the plant M5000_2 regarding the task design verification and dynamic structural analysis are given.
Wind turbines on offshore sites (OWECs) are subjected to combined loads from wind and waves. These dynamic loads, with a frequency content within the range of the natural frequencies of the structures, cause fatigue-effective stresses in the substructures of wind turbines. Therefore, the examination of natural frequencies is an important part within the design process of wind turbines. The quality of the numerical models for such calculations is of great importance, since the certification guidelines permit only small uncertainties in modal analysis results. The accuracy of the parameters of the numerical model can only be achieved through a comparison of simulation results with corresponding test results. Therefore, it is necessary to measure the dynamic behaviour of all components of the wind turbines simultaneously. This is true not only for the design verification, but also for monitoring the OWECs in operation. The potential of integrated systems for monitoring-based maintenance optimisation should thus be used.
To ensure a high operational reliability of offshore wind turbines (OWEC) with economically acceptable repair and maintenance efforts, comprehensive diagnosis and supervision concepts are required. Automatic monitoring Systems will be an essential part of such concepts. Because of the fact, that during Operation there will be static and dynamic interaction between the components ‘structure’, ‘machinery’ and ‘blades’ it is necessary to develop the monitoring techniques in an overall concept. These monitoring Systems are supposed to be applied for the design and testing as well as for the Operation and maintenance phases. The knowledge of the dynamic behavior of wind turbines is important both for the design and for a safe Operation. The available monitoring data from a period of three years, allow first conclusions on the long-term Operation of such Systems in terms of quality requirements to the instrumentation to the structure and the rotor blades
To ensure a high operational reliability of future generations of offshore wind conversion systems (OWEC) with economically acceptable repair and maintenance efforts, comprehensive diagnosis and supervision concepts are required. Automatic monitoring systems will be an essential part of such concepts. Because of the fact, that during operation there will be static and dynamic interaction between the components 'structure', 'machinery' and 'blades' it is necessary to develop the monitoring techniques in an overall concept. These monitoring systems are supposed to be applied for the design and testing as well as for the operation and maintenance phases. The used methods are focused on the design requirements for the structure, which are stated in the respective standards and certification guidelines. For the validation of the design, methods are specified which would be also applicable for SHM in the operating condition, e.g. for the evaluation of the structural conditon possibly after the occurrence of damages or changes. The further task consists in the realization of condition monitoring for all components, aiming at early damage detection and the observation of the damage development and its evaluation. Here the task consists of determining with assessment procedures the optimum time for maintenance actions to be carried out.
Vibration-based structural health monitoring of a wind turbine system. Part I: Resonance phenomenon
(2015)
This paper is focused on a resonance phenomenon of a wind turbine system in 5 MW class, on the basis of dynamic signals acquired continuously from the tubular tower under normal operational conditions during two years.
Firstly, technique specifications of the wind turbine system are introduced and a finite element model is developed to characterize the structural dynamic properties. The following part describes the continuous dynamic monitoring system integrated with an automated operational modal analysis procedure using the poly-reference Least Squares Complex Frequency domain (p-LSCF) method. Subsequently, variations and mutual relationships of environmental/operational factors such as vibration amplitude, temperature, wind speed, rotation speed of blades, pitch angle and nacelle direction are also presented. Finally, significant resonance is observed due to the fundamental frequency of the tower matching with the harmonic frequency induced by the rotation of three blades. As the rotation speed of rotor approaches to 8 rpm, the vibration amplitude of the tower increases significantly and the corresponding damping value decreases. With the further rising wind velocity, the rotation speed of blades stops increasing and the input energy just contribute to accumulate the vibration amplitude of tower. Such observation indicates the Sommerfeld effect that aggravates the resonance phenomenon. A vibration control device is necessary to minimize the excessive structural responses.
A companion paper will further discuss the environmental/operational effects on dynamic properties of the wind turbine system under the operational conditions.