Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (87) (entfernen)
Schlagworte
- Interlaboratory comparison (9)
- Gas chromatography (6)
- Extraction (5)
- Analysis (4)
- Boden (4)
- Brominated flame retardant (4)
- Groundwater (4)
- HPLC-MS/MS (4)
- Breath (3)
- Chiral separation (3)
- Mass spectrometry (3)
- Microplastics (3)
- Proficiency testing (3)
- Ringversuch (3)
- VOC (3)
- Volatile organic compounds (3)
- Volatilome (3)
- A549 (2)
- Alcohol marker (2)
- Aniline (2)
- Certification (2)
- Certified reference materials (2)
- Chloroanilines (2)
- Crystal structure (2)
- Degradation (2)
- Diastereomers (2)
- Ethyl glucuronide (2)
- Flame retardant (2)
- Food (2)
- Fortification (2)
- GC-FID (2)
- GC-MS (2)
- HBCD (2)
- Hydroxylation (2)
- Kinetics (2)
- Liquid chromatography (2)
- Long term stability (2)
- Lung cancer (2)
- Methylanilines (2)
- Micropulverization (2)
- Mikroplastik (2)
- Molecular dynamics (2)
- Organic pollutants (2)
- Phenols (2)
- Reference materials (2)
- Sampling (2)
- Sewage sludge (2)
- Soil (2)
- Solid phase microextraction (2)
- Summation parameter (2)
- AOX (1)
- APCI (1)
- Abfall (1)
- Absolute configuration (1)
- Abwasser (1)
- Acrylamid (1)
- Active sampling (1)
- Adsorption (1)
- Akkreditierung (1)
- Analysis and identification (1)
- Analytik (1)
- Anomalous dispersion (1)
- Anomeric configuration (1)
- Antioxidant properties (1)
- Arrhenius model (1)
- Artificial weathering (1)
- BFR (1)
- BPA (1)
- BTEX (1)
- Bacteria (1)
- Benzenes (1)
- Beta-cyclodextrin (1)
- Binding affinity (1)
- Bio test battery (1)
- Bioaccumulation (1)
- Biochar (1)
- Biofouling (1)
- Bioisomerization (1)
- Biomarkers (1)
- Bleaching (1)
- Bromierte Falmmschutzmittel (1)
- Brominated flame retardants (1)
- CEC-L-103 (1)
- CRM (1)
- Calibration (1)
- Calix[4]resorcinarenes (1)
- Cancer (1)
- Chemical analysis (1)
- Chemometrics (1)
- Collaborative trial (1)
- Combustion (1)
- Conformational chirality (1)
- Contaminated site (1)
- Contamination (1)
- Crosslinking (1)
- Crystal structures (1)
- Cysteic acid (1)
- Cytochrom (1)
- Cytochrome P450 (1)
- Cytochromes (1)
- D-Glucuronic acid derivates (1)
- DEHP (1)
- DFA (1)
- Data-to-parameter ratio = 20.4 (1)
- Degradation of refrigerants (1)
- Derivatisation (1)
- Derivatisierung (1)
- Derivatization (1)
- Detection dog (1)
- Diffusionsprobe (1)
- Dithiocarbamate (1)
- Dithiopercarbamate (1)
- ERM (1)
- Einfluß (1)
- Eingnugsprüfung (1)
- Elution order (1)
- Enantiomer fraction (1)
- Enantiomer-specific bioaccumulation (1)
- Enantiomer-specific determination (1)
- Enantiomeric fraction (1)
- Enantiomers (1)
- Equivalence (1)
- Equivalent carbon number (1)
- European Reference Material (1)
- European reference material (1)
- European waste list (1)
- External quality management (1)
- FTIR imaging (1)
- Fish feeding experiment (1)
- Flame ionization detection (1)
- Flame retardants (1)
- Fluoroacetic acid (1)
- Fuel (1)
- Fungi (1)
- Furfurals (1)
- GC (1)
- GC-AED (1)
- GC/MS (1)
- GC/MS-MS (1)
- GCMS (1)
- Gaschromatographie (1)
- Gasoline (1)
- Ground water (1)
- Groundwater monitoring (1)
- Grundwasser (1)
- HBCDs (1)
- HPLC (1)
- HPLC-DAD (1)
- HPLC-ESI-MS/MS (1)
- HPLCMS/MS (1)
- Hair (1)
- Hair testing (1)
- Hexabromcyclododecan (1)
- High resolution NMR (1)
- High-throughput analysis (1)
- Homogeneity (1)
- Honey bees (1)
- Hydrocarbons (1)
- Hydrochar (1)
- Hydrogen bonded molecular capsule (1)
- ICP-MS (1)
- ICP-OES (1)
- IR spectrometry (1)
- Indoor air (1)
- Intercomparison (1)
- Interlaboratory study (1)
- International intercomparison (1)
- Ion chromatography (1)
- Isoleucin (1)
- Isomerisation (1)
- Kalibrierstand (1)
- Kompetenzbewertung (1)
- LC-MS (1)
- LC/MS-MS (1)
- LHKW (1)
- Lung cancer cell culture (1)
- MKW (1)
- MOSH/MOAH (1)
- Marker (1)
- Markov process (1)
- Measurement uncertainty (1)
- Metabolism of HBCD (1)
- Metaboliten (1)
- Metal-organic complexes (1)
- Methane (1)
- Method development (1)
- Method validation (1)
- Metrology (1)
- Micropulverized extraction (1)
- Mineral oil (1)
- Mineral oil hydrocarobons (1)
- Mineralölkohlenwasserstoff (1)
- Mineralölkohlenwasserstoffe (1)
- Minor isomers (1)
- Moisture (1)
- Molecular simulation (1)
- Municipal sludge (1)
- NPE (1)
- Nation metrology institutes (1)
- Near Infrared Spectroscopy (1)
- Network (1)
- Odour discrimination task (1)
- Optical rotation (1)
- Organohalogen compounds (1)
- Oxidation (1)
- PAH (1)
- PCB (1)
- PDB (1)
- PLS-DA (1)
- Passive sampling (1)
- Pentachlorophenol (1)
- Pflanzenwachstum (1)
- Phase I metabolism (1)
- Phosphous recovery (1)
- Photometric P determination (1)
- Polybrominated biphenyls (PBBs) (1)
- Polybrominated diphenyl ethers (PBDEs) (1)
- Polycyclic aromatic hydrocarbons (1)
- Polymer (1)
- Polypropylene (1)
- Polystyrene (1)
- Polyurethane (1)
- Polyurethanes (1)
- Predicting sites of metabolism (1)
- Probe (1)
- Probenahme (1)
- Process water (1)
- Proficiency Testing (1)
- Proficiency test (1)
- Pulverization (1)
- Pumpprobe (1)
- Pyrolysis (1)
- QM (1)
- Quality assurance (1)
- Qualitätsmanagement (1)
- Qualitätssicherung (1)
- R factor = 0.043 (1)
- Rainwater (1)
- Raman imaging (1)
- Rate matrix (1)
- Rearrangement (1)
- Reference material (1)
- Reference organisms (1)
- Referenzmaterial (1)
- Referenzmaterialien (1)
- Regulation (1)
- Remediation (1)
- Reproducibility (1)
- Ring test (1)
- Ring test structure (1)
- SEC (1)
- SPME (1)
- Safety (1)
- Sample (1)
- Sediment (1)
- Shelf life (1)
- Simulation (1)
- Single-crystal X-ray study (1)
- Sniffer dogs (1)
- Society of hair testing (1)
- Software (1)
- Sonication (1)
- Sorption (1)
- Stabilisation (1)
- Stability (1)
- Stakeholders (1)
- Standardisation (1)
- Standardization (1)
- Static headspace (1)
- Statistical thermodynamics (1)
- Statistics (1)
- Support vector machines (1)
- Suspended organic matter (1)
- Synthesis (1)
- Synthetic air (1)
- T = 273 K (1)
- TBBPA-dbpe (1)
- TED-GC-MS (1)
- TFA (1)
- Thermal degradation (1)
- Thermo-desorption (1)
- Total organic carbon (1)
- Total petroleum hydrocarbons (1)
- Trace elements (1)
- Traceability (1)
- Trichloroethene (1)
- Umweltanalytik (1)
- Urine (1)
- Vinyl chloride (1)
- Waste (1)
- Waste ecotoxicity (1)
- Waste legislation (1)
- Waste wood (1)
- Wastewater (1)
- X-ray (1)
- X-ray analysis (1)
- X-ray structure analyses (1)
- Zinc (1)
- dog training (1)
- herbs (1)
- reference materials, (1)
- scent dog (1)
- smell (1)
- training model (1)
- wR factor = 0.121 (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (19)
- 1.7 Organische Spuren- und Lebensmittelanalytik (19)
- 4 Material und Umwelt (4)
- 6 Materialchemie (4)
- 5 Werkstofftechnik (3)
- 6.3 Strukturanalytik (3)
- 4.3 Schadstofftransfer und Umwelttechnologien (2)
- 5.3 Polymere Verbundwerkstoffe (2)
- 6.6 Physik und chemische Analytik der Polymere (2)
- 1.2 Biophotonik (1)
Paper des Monats
- ja (1)
Polyether and -ester urethanes (PU) were exposed to artificial weathering at 40 °C and artificial UV radiation in a weathering chamber. In 3 parallel exposures, humidity was varied between dry, humid, and wet conditions. Material alteration was investigated by various analytical techniques like size exclusion chromatography
(SEC), liquid chromatography-infrared spectroscopy (LC-FTIR), thermal-desorption gas chromatography-mass spectrometry (TD-GC-MS), fluorescence mapping and dynamic mechanical analysis (DMA). Our results show that depending on the weathering conditions, different degradation effects can be observed. By means of SEC an initial strong decrease of the molar masses and a broadening of the mass distributions was found. After a material dependent time span this was followed by a plateau where molar mass changes were less significant. A minor moisture-dependent degradation effect was only found for polyester PU. Fluorescence measurements on two materials revealed an increase in the luminescence intensity upon weathering process reaching a saturation level after about 500 h. The changes in the optical properties observed after different exposure conditions and times were very similar. The TD-GC-MS data showed the fate of the stabilizers and antioxidant in the course of weathering. LC-FTIR measurements revealed a change in peak intensities and the ratio of urethane and carbonyl bands.
The development of a test to evaluate the degradation of semi-volatile fuels as diesel by microorganisms is presented. This method is based on the principles described in the CEC-L-103 Standard procedure that is exclusively meant for testing the biodegradability of non-volatile lubricants. Therefore, significant modifications involve aseptic conditions for testing specific microorganisms and conducting the test in closed vessels avoiding evaporation losses, while fuel quantification using gas chromatography-flame ionization detection (GC-FID) is retained. It is suggested that the modified procedure should enable routine application for semi-volatile hydrocarbon-based fuels. GC-FID provides additionally valuable information on the alteration of fuel component patterns during biodegradation. The procedure was successfully tested using two bacteria (Pseudomonas aeruginosa and Sphingomonas sp.) and two yeasts (Moesziomyces sp. and Candida sp.) isolated from real diesel contamination cases. All tested microorganisms caused a significant degradation of diesel fuel achieving hydrocarbon degradation percentages ranging from 23% to 35%. Specific aspects on the test modification and prospects for further modification regarding targeted investigations in the field of fuel contamination by microorganisms are briefly discussed.
A Proof of Concept: Are Detection Dogs a Useful Tool to Verify Potential Biomarkers for Lung Cancer?
(2018)
Early and reliable diagnostic test is essential for effective therapy of lung cancer. Volatile organic compounds that are characteristic for cancer could serve as valuable biomarkers in cancer diagnosis. Both trace analytical and detection dog approaches give some evidence for the existence of such biomarkers. In this proof of concept, study dogs and trace analysis were implemented in combination to gain more information concerning cancer biomarkers. Two dogs were trained to distinguish between absorbed breath samples of lung cancer patients and healthy persons and succeeded with correct identification of patients with 9/9 and 8/9 and correct negative indications from of 8/10 and 4/10 samples from healthy individuals. A recent observational study found that breath samples from lung cancer patients showed an increase in 1-butanol, 2-butanone, 2-pentanone, and hexanal. Synthetic air samples were therefore fortified with these compounds and adsorbed to a fleece. Tested against breath samples from healthy probands, on presentation to the dogs these synthetic samples provoked an indication in three out of four samples. We were able to demonstrate that a combination of the natural nose of a dog and a trace analytic technique can be a valuable concept in the search for cancer biomarkers.
Zinc dialkyl dithiocarbamoylsulfinates have been proposed as intermediates in the antioxidant action of the respective zinc dialkyl dithiocarbamate additives in hydrocarbon-based plastics and lubricants. As a model compound, zinc diisobutyl dithiocarbamoylsulfinate, [Zn(C9H18NO2S2)2], has been prepared and its crystal structure determined.