Filtern
Dokumenttyp
Schlagworte
- Ablösungen (2)
- Accelerator mass spectrometry (2)
- Active thermography (2)
- Aktive Thermografie (2)
- 1-m³-Behälter (1)
- 20-l-Kugel (1)
- AFM (1)
- Accelerated stress testing (1)
- Active thermal cycling (1)
- Bauwerksfassaden (1)
The first international round-robin exercise for the measurement of the long-lived radionuclide 10Be has been conducted. Ten participating accelerator mass spectrometry (AMS) facilities have each measured three samples at the 10-12 to 10-14 10Be/9Be level. All results have been made traceable to the NIST SRM 4325 standard to avoid additional discrepancies that arise when different facilities use different calibration materials. Hence, the data concentrates on pure measurement distinctions. Multivariate statistical investigations have been performed to reveal a bias between facilities, i.e. two distinguished groups could be identified. Maximum discrepancies between two single facilities are in the range of 6–31% depending on the absolute 10Be/9Be value. These findings should be considered when comparing 10Be data produced at one AMS facility with that produced at another facility, which is e.g. often the case for in situ 10Be dating studies. Round-robin exercises are a very helpful tool as part of an overall quality assurance scheme to improve the accuracy, and not only the precision, of AMS data.
Active thermography is well suited for the detection of delaminations and cracks in façade elements like plaster and tiles. Not only artificial heating but also solar heating can be used if the adjustment of the façade and the weather conditions are suitable. Optical methods like laser scanners, photogrammetric methods and crack tracking sensors are providing geometrical 3D data which can be used for a 3D mapping of thermograms and for providing data with higher geometrical resolution. Thus, by the combination and fusion of these data, a comprehensive mapping and monitoring of damages of façade systems is possible.
Im Beitrag werden Verfahren und Strategien basierend auf optischen und thermografischen Methoden zur Lokalisierung, Erfassung und Bewertung von Putzablösungen und Ablösungen von Fassadenelementen vorgestellt. Abgelöste Fassadenbereiche zeigen dabei sowohl geometrische als auch thermische Auffälligkeiten, die im Rahmen eines Monitoring auch über größere Zeiträume verfolgt werden können. Als optische Verfahren werden die Stereophotogrammetrie und die trackingbasierte taktile 3D-Erfassung von Oberflächenmerkmalen eingesetzt. Zur Charakterisierung verdeckter Ablösungen und Bauteile wird die aktive Thermografie mit natürlicher und künstlicher Erwärmung der Bauteiloberfläche verwendet. Systematische Untersuchungen an Probekörpern und Fallstudien (Magdeburger Dom, Wandbild in Cobbelsdorf) zeigen, wie u. a. mit der Verfahrenskombination Ablösungen und Materialinhomogenitäten unterschieden werden können.
In this contribution, the development and application of optical and thermographic methods for the nondestructive evaluation of delaminations, cracks and further substructures in Connection with bulging is presented.
Since delaminated fagade elements show geometric as well as thermal anomalies, surface geometry and defects beneath the surface were investigated. As methods, Stereo photogrammetry, a tracking based method for tactile recording of geometric 3D data and active thermography were used. Two case studies were assessed with a combination of these methods: the plaster scratches at the Magdeburg Cathedral and a mural painting in Cobbelsdorf, both located in Germany. While the plaster scratches have been investigated by artificial heating with an infrared radiator, the rural painting was tested by analysing the temperature increase due to solar heating.
In diesem Beitrag werden Verfahren und Strategien basierend auf optischen und thermografischen Methoden zur Lokalisierung, Erfassung und Bewertung von Putzablösungen, Ablösungen von Fassadenelementen und Rissen vorgestellt. Abgelöste Fassadenbereiche und Risse zeigen dabei sowohl geometrische als auch thermische Auffälligkeiten, die im Rahmen eines Monitoring auch über größere Zeiträume verfolgt werden können. Als optische Verfahren werden die trackingbasierte taktile 3D‐Erfassung von Oberflächenmerkmalen und die Stereophotogrammetrie eingesetzt. Zur Charakterisierung verdeckter Ablösungen und Bauteile wird die aktive Thermografie mit natürlicher und künstlicher Erwärmung der Bauteiloberfläche verwendet. Systematische Untersuchungen an Probekörpern und Fallstudien (Magdeburger Dom, Wandbild in Cobbelsdorf, Giebichensteinbrücke) zeigen, wie u. a. mit der Verfahrenskombination die Schäden charakterisiert werden können.
Aluminium is still one of the most important contact metallisations for power electronic chips like MOSFETs or IGBTs. With a large difference in thermal expansion coefficients (CTEs) between aluminium and silicon and the temperatures generated in hot-spots during high power transients, these layers are prone to failure due to thermo-mechanical fatigue. Usually lifetime assessment is done by subjecting dedicated test specimens to standardised stress tests as e.g. active or passive thermal cycling. This paper proposes a novel method for accelerated stress testing and lifetime modelling of thin aluminium films in the high-cycle fatigue regime by isothermal mechanical loading. The proposed novel test method is suggested to complement or replace resource-demanding thermal cycling tests and allow simple in-situ monitoring of failure.
A first international 36Cl interlaboratory comparison has been initiated. Evaluation of the final results of the eight participating accelerator mass spectrometry (AMS) laboratories on three synthetic AgCl samples with 36Cl/Cl ratios at the 10-11, 10-12, and 10-13 level shows no difference in the sense of simple statistical significance.
However, more detailed statistical analyses demonstrate certain interlaboratory bias and underestimation of uncertainties by some laboratories. Following subsequent remeasurement and reanalysis of the data from some AMS facilities, the round-robin data indicate that 36Cl/Cl data from two individual AMS laboratories can differ by up to
17%. Thus, the demand for further work on harmonising the 36Cl-system on a worldwide scale and enlarging the improvement of measurements is obvious.