Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (11)
- Zeitschriftenartikel (3)
- Buchkapitel (3)
- Vortrag (3)
- Posterpräsentation (1)
Schlagworte
- UHPC (4)
- Baustoffe (3)
- Beton (3)
- Ionic liquid (3)
- Architectural Concrete (2)
- Compressive strength (2)
- Concrete (2)
- Facade Elements (2)
- Fertigteil (2)
- Fractography (2)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (3)
Structural supercapacitor electrolytes based on bicontinuous ionic liquid-epoxy resin systems
(2013)
'Structural electrolytes' retain the desirable mechanical characteristics of structural (epoxy) resins whilst introducing sufficient ionic conductivity to operate as electrolytes in electrochemical devices. Here, a series of ionic liquid–epoxy resin composites were prepared to identify the optimum system microstructure required to achieve a high level of multifunctionality. The ionic conductivity, mechanical properties, thermal stability and morphology of the cured epoxy based structural electrolytes were studied as a function of phase composition for three fully formulated high performance structural epoxy systems. At only 30 wt% of structural resin and 70 wt% of ionic liquid based electrolyte, stiff monolithic plaques with thicknesses of 2–3 mm were obtained with a room temperature ionic conductivity of 0.8 mS cm-1 and a Young's modulus of 0.2 GPa. This promising performance can be attributed to a long characteristic length scale spinodal microstructure, suggesting routes to further optimisation in the future.
Polymer-based electrolytes based on commercially available epoxy resins were prepared through the addition of a liquid electrolyte, a solution of a lithium salt in an ionic liquid. The polymer monoliths were characterized using impedance spectroscopy, 3-point bending test, scanning electron microscopy (SEM) and nitrogen adsorption (BET). The balance of ionic conductivity and flexural modulus is crucially dependent on the relative proportions of epoxy resin to electrolyte. Also the effect of the liquid electrolyte on curing kinetics and processing was assessed by complex viscosity measurements and differential scanning calorimetry (DSC). Only one out of the three resins investigated exhibited a significant acceleration effect.
Ziel war die Entwicklung neuer Konzepte für die Herstellung sicherer, energieeffizienter und erschwinglicher Materialien für Gebäudehüllen und Innenwände für ein gesünderes Wohnklima.
Es werden Komposit-Fertigteile aus UHPC mit Wärmedämmung aus Porenbeton und aus Textilfaserbeton mit Wärmedämmung aus Schaumbeton vorgestellt.
Diskutiert werden die Strategien zum Erreichen einer erhöhten Dauerhaftigkeit und Ressourceneffizienz sowie zur Erzeugung multifunktionaler Oberflächen.
The project has developed a variety of new multifunctional and flexible building components for a healthier indoor environment. [H] house solutions are durable, energy efficient, safe and affordable. They are suitable for use in new buildings and for renovation. [H] house solutions cover aspects of long service life, reduced maintenance and long-term improvement of energy efficiency.
Ziel war die Entwicklung neuer Konzepte für die Herstellung sicherer, energieeffizienter und erschwinglicher Materialien für Gebäudehüllen und Innenwände für ein gesünderes Wohnklima.
Es werden Komposit-Fertigteile aus UHPC mit Wärmedämmung aus Porenbeton und aus Textilfaserbeton mit Wärmedämmung aus Schaumbeton vorgestellt.
Diskutiert werden die Strategien zum Erreichen einer erhöhten Dauerhaftigkeit und Ressourceneffizienz sowie zur Erzeugung multifunktionaler Oberflächen.
Industrial byproducts and natural pozzolanas are increasingly being used as supplementary cementitious materials. In the group of natural pozzolanas volcanic ashes are the most prominent. Despite the fact that volcanic pozzolanas were used since Roman times, not much is known about their role in influencing the long term durability of concrete. The paper presents results of the volcanic pozzolana ‘Rhenish trass’, which is quarried in western Germany and its role during an alkali silica reaction (ASR). Field data and laboratory experiments indicate that trass releases alkalis into the pore solution but also changes cement paste chemistry and alkali binding behavior. There seems to be a sensitive balance between alkali release and increase of alkali binding capacity, both mechanisms crucial for the course of an ASR in concrete.
The European building sector is moving towards more complex and high-tech building approaches. While focusing on energy efficiency, aspects e.g. occupant health, sustainability and life cycle costing are often neglected. This study highlights the potential of earthen plasters in combination with natural ventilation for low-tech solutions.
The EU funded project [H]house established the outstanding performance of earthen materials in light of hygrothermal and air purifying properties, which were further supported by experimental data from monitoring of naturally ventilated pilot buildings in Berlin. Additionally, [H]house demonstrated through LCC an increased cost efficiency of earth based low-tech solutions in comparison to conventional constructions relying on mechanical ventilation.
The aim of this study was to develop a lightweight composite facade element for new buildings and for the refurbishment of existing facades. These composite elements have been developed combining an insulation layer of autoclaved aerated concrete (AAC) with an external ultrahighperformance concrete (UHPC) supporting layer. This solution allows avoiding the use of connectors and facilitates the production procedure. The structural behavior of the facade elements is mainly influenced by the presence of the upturning edges that are able to increase the stiffness of the element and reduce the thickness of the external layer. The insulation material has no influence on the structural behavior of the UHPC boxes. Flexural tests were carried out to investigate a potential detachment of the external layer from the upturning edge. The photogrammetric Analysis used during the flexural tests essentially confirmed that the bond between the two UHPC layers cast in two steps is reliable. The quality of the bond between the external layer and the upturning edge is a key parameter to define the bearing capacity of the element.