Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Sammelband (32) (entfernen)
Referierte Publikation
- nein (32)
Schlagworte
- VOC (7)
- SVOC (6)
- Bauprodukte (5)
- Emissionen (5)
- Geruch (4)
- Flame retardants (3)
- Material emission (3)
- AbBB-Schema (2)
- Biocide (2)
- Blauer Engel (2)
The emission levels of high boiling brominated (BFR) and phosphoric (POC) flame retardants (FR) in different materials were examined. For the determination of the emission rate the tests were done in different emission test chambers and cells under standard conditions (23 C, 50% RH and fixed area specific air flow rates). Selected products, e.g. printed circuit boards, were investigated at elevated temperature (e.g. 60 C) to simulate working conditions. Applied analytical techniques for the air samples adsorbed on polyurethane foam (PUF) are soxhlet and ultrasonic extraction. Different conditions were used to analyse the FR via GC-MS. Based on the first results it could be demonstrated that the emission depends on material density and surface condition. The concentrations over time obtained for tris(3-chloropropyl)-phosphate, e.g., from emission test chamber and cell show a good correlation, partly the measured concentration are different. Sampling at elevated temperature gives higher concentrations.
Do particleboards produced with recycled wood contribute to indoor air pollution with biocides?
(2003)
The present study comprises the characterisation of museum show cases concerning their hazardous potential for
art objects. In order to estimate potential risks of damage the emission of volatile organic compounds coming from
several construction materials is monitored and different air exchange rates from exhibit cases are determined. For
the determination of the VOCs different methods were applied. The first step is a direct thermal extraction of the
materials followed by emission test chamber measurements. The tracer gas method with N2O that is used in this study is a convenient procedure to investigate air exchange rates under working conditions greater than 0.05 d-1. The results of this study confirm the importance of the careful choice concerning building materials for show cases. Furthermore the analyses clarify that certain organic compounds might be a problem for the exhibits in show cases with low air exchange rates.
Schadstoffe beschäftigen derzeit Museen weltweit Heute weiß man, dass diese auch aus Materialien, die für den Ausstellungsbau verwendet werden, austreten können, was eine Gefahr für Exponate darstellt. Ein neues Verfahren namens BEMMA bietet nun erstmalig die Möglichkeit, relativ schnell und effektiv eine problemorientierte Untersuchung und Bewertung mit belastbaren und reproduzierbaren Ergebnissen vorzunehmen.