Filtern
Erscheinungsjahr
Dokumenttyp
Sprache
- Englisch (18)
- Deutsch (9)
- Mehrsprachig (1)
Schlagworte
- VOC (12)
- Emissionen (7)
- SVOC (6)
- Bauprodukte (5)
- Emission test chamber (4)
- Emissionsmesskammern (4)
- Interlaboratory study (4)
- VOC emission (4)
- AgBB (3)
- Chamber test (3)
The emission levels of high boiling brominated (BFR) and phosphoric (POC) flame retardants (FR) in different materials were examined. For the determination of the emission rate the tests were done in different emission test chambers and cells under standard conditions (23 C, 50% RH and fixed area specific air flow rates). Selected products, e.g. printed circuit boards, were investigated at elevated temperature (e.g. 60 C) to simulate working conditions. Applied analytical techniques for the air samples adsorbed on polyurethane foam (PUF) are soxhlet and ultrasonic extraction. Different conditions were used to analyse the FR via GC-MS. Based on the first results it could be demonstrated that the emission depends on material density and surface condition. The concentrations over time obtained for tris(3-chloropropyl)-phosphate, e.g., from emission test chamber and cell show a good correlation, partly the measured concentration are different. Sampling at elevated temperature gives higher concentrations.
Nicht nur Schadstoffe aus der Umwelt können Museumsexponate schädigen. Auch interne Schadstoffquellen wie objektimmanente Exhalate und Emissionen von Lösemitteln oder organischen Säuren können den wertvollen Gu¨tern Schaden zufu¨gen. Auf Schadstoffe zu pru¨fen sowie geeignete Messmethoden zu entwickeln und zu optimieren, ist daher von großer Bedeutung. Neuste Forschungen stellen die Autoren vor.
Do particleboards produced with recycled wood contribute to indoor air pollution with biocides?
(2003)
Several construction and building materials, including wood, glue and coatings, are possible sources of very volatile organic compounds (VVOCs) and volatile organic compounds (VOCs) like formic and acetic acid. Due to very high air tightness and very low air exchange rates in new buildings concentrations of these harmful substances can increase considerably. To minimize the risk, emissions from building products should be identified and quantified. With the common standard method, this means Tenax® sampling followed by thermal desorption and GC-MS analysis, these acids could not be detected sufficiently. The aim oft this study is the comparison of two different methods for the determination of acetic and formic acid. The sampling of method one, which is usually used for identification and quantification of VOCs, is done in accordance with ISO 16000-6 and ISO 16017-1 on Carbotrap® 202 multi-bed thermal desorption tube by subsequent identification and quantification with GC-MS. Method two is based on sampling on 2,4-dinitrophenylhydrazine (DNPH) cartridges, derivatisation, elution, identification and quantification of the derivatives with LC-MS/MS (liquid chromatography mass spectrometry/mass spectrometry).