Filtern
Dokumenttyp
Sprache
- Englisch (3)
Schlagworte
- GMR (2)
- Aerospace (1)
- Eddy current (1)
- Eddy current (EC) (1)
- Eddy current testing (ET) (1)
- Hidden defects (1)
- Magnetic flux leakage (1)
- Magnetic sensor (1)
- Magneto resistance (MR) (1)
- Sensor array (1)
- Simulation (1)
- TMR (1)
Magneto-resistive (MR) sensor arrays are suited for high resolution eddy current testing (ET) of aerospace components due to two significant advantages compared to conventional coil systems. First, to obtain high spatial resolution they can be manufactured down to the µm-regime without losing their outstanding field sensitivity. Secondly, MR technology has a relatively frequency-independent sensitivity in the range of common ET-frequencies thus providing a benefit for low frequency applications.
This paper presents measurements using MR array probes consisting of 32 TMR-elements (tunnel magneto resistance), an ASIC, and subsequent readout components. A source for generating the eddy currents inside the material under test is also implemented onboard of the PCB. These probes were developed in the IMAGIC-project* for detection and imaging of surface breaking defects.
The performance of the new sensor system has been investigated for several mock-ups, Aluminum and Titanium plate specimens having small adjacent boreholes with diameter of 0.44 mm and micro notches in the µm-range, respectively. To compare our results we used conventional eddy current probes. The MR sensor elements have a length of around 60 µm leading to a nearly 'point like' measurement. Neighbouring boreholes (depth 0.25 mm) with a separation of 0.6 mm between their centres could be resolved with a good SNR, and more important, the boreholes could be confidently distinguished using the TMR-probes. In case of conventional probes a reliable separation was not possible. In this paper we present the MR-ET-probes of the IMAGIC consortium and a comparison with conventional techniques.
*The IMAGIC-project ('Integrated Magnetic imagery based on spIntronics Components', 2011 – 2014, project reference: 288381) was funded by the European Commission, Seventh Framework Programme. Further partners involved in the consortium beside BAM and CEA were INESC-ID and INESC-MN (Portugal), Sensitec GmbH (Germany), Tecnatom S.A. (Spain), and Airbus Group (France).
Eddy Current Technique is a powerful method for detection of surface notches and of buried flaws during inspection of metallic parts. Recent EC array probes have demonstrated a fast and efficient control of large surfaces. Nevertheless, when the size of flaws decreases or the defect is rather deep, traditional winding coil probes turn out to be useless. Magnetoresistive sensors present the advantages of flat frequency response and micron size. These sensors are hence very attractive for the detection of buried defects that require low frequencies because of skin depth effect. An optimization of the probe with magnetoresistive sensors as receivers has been made by simulations using CIVA software and finite elements methods with OPERA. EC probes for buried flaw detection have been designed. Experimental results have been compared with simulations.
We present a simulation study which pursues the objective to find probe geometries for a MR-based eddy current (EC) probe (MR magneto resistance, e.g., GMR giant magneto resistance, TMR tunnel magneto resistance). MR sensor technology exhibits two significant advantages compared with conventional coil systems. First, MR sensors are relatively frequency-independent within common EC-frequency ranges which enable us to operate them in hidden defects testing problems. Secondly, MR technology is well suited for miniaturization helping us to design small elements in the order of below 100 µm. In this paper simulation and experimental results obtained with the probes for low frequency application, i.e. for hidden defects detection are discussed.
Our simulations are based on two different approaches for a better validation, a commercial finite element method software (Opera, Vectorfields) and the semi-analytical software CIVA. We investigated both coil arrangement in order to excite sufficient high eddy currents inside the test samples and position of MR-elements at the array chip. In doing so the MR sensors were positioned that they are not exposed to excitation fields. In addition, different coil geometries, in particular coil length, e.g. Ι = 20 mm, were analyzed in order to generate a consistent eddy current distribution beneath an array of up to 32 MR-elements. To prove obtained probe principles we built GMR-EC-probes. The first test measurements are in good agreement with the simulations performed by BAM and CEA. On basis of our findings the IMAGIC consortium developed new MR-EC-probes using integrated ASIC technology.