Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (13)
- Beitrag zu einem Tagungsband (4)
- Sonstiges (2)
Schlagworte
- pnCCD (2)
- AEROMET II (1)
- Acid resistance (1)
- Aerosol (1)
- Air quality monitoring (1)
- Alkali-activated materials (1)
- Ammonia in ambient air (1)
- Analytical services (1)
- Baustoffrecycling (1)
- Built environment (1)
Organisationseinheit der BAM
- 6 Materialchemie (3)
- 4 Material und Umwelt (2)
- 6.3 Strukturanalytik (2)
- 7 Bauwerkssicherheit (2)
- 7.4 Baustofftechnologie (2)
- 1 Analytische Chemie; Referenzmaterialien (1)
- 1.2 Biophotonik (1)
- 2 Prozess- und Anlagensicherheit (1)
- 2.1 Sicherheit von Energieträgern (1)
- 4.0 Abteilungsleitung und andere (1)
We present a new high resolution X-ray imager based on a pnCCD detector and a polycapillary optics. The properties of the pnCCD like high quantum efficiency, high energy resolution and radiation hardness are maintained, while color corrected polycapillary lenses are used to direct the fluorescence photons from every spot on a sample to a corresponding pixel on the detector. The camera is sensitive to photons from 3 to 40 keV with still 30% quantum efficiency at 20 keV. The pnCCD is operated in split frame mode allowing a high frame rate of 400 Hz with an energy resolution of 152 eV for Mn Kα (5.9 keV) at 450 kcps. In single-photon counting mode (SPC), the time, energy and position of every fluorescence photon is recorded for every frame. A dedicated software enables the visualization of the elements distribution in real time without the need of post-processing the data. A description of the key components including detector, X-ray optics and camera is given. First experiments show the capability of the camera to perform fast full-field X-Ray Fluorescence (FF-XRF) for element analysis. The imaging performance with a magnifying optics (3×) has also been successfully tested.
A metrological approach to improve accuracy and reliability of ammonia measurements in ambient air
(2016)
The environmental impacts of ammonia (NH3) in ambient air have become more evident in the recent decades, leading to intensifying research in this field. A number of novel analytical techniques and monitoring instruments have been developed, and the quality and availability of reference gas mixtures used for the calibration of measuring instruments has also increased significantly. However, recent inter-comparison measurements show significant discrepancies, indicating that the majority of the newly developed devices and reference materials require further thorough validation. There is a clear need for more intensive metrological research focusing on quality assurance, intercomparability and validations. MetNH3 (Metrology for ammonia in ambient air) is a three-year project within the framework of the European Metrology Research Programme (EMRP), which aims to bring metrological traceability to ambient ammonia measurements in the 0.5–500 nmol mol−1 amount fraction range. This is addressed by working in three areas: (1) improving accuracy and stability of static and dynamic reference gas mixtures, (2) developing an optical transfer standard and (3) establishing the link between high-accuracy metrological standards and field measurements. In this article we describe the concept, aims and first results of the project.
The publicly available document encapsulates the first version of the Catalogue of Services of the future EC4Safenano Centre (CoS 2019).
The CoS 2019 is structured in 12 Service Categories and 27 Service Topics, for each of the 12 categories considered. This architecture configures a 12 x 27 matrix that allows ordering the potential EC4Safenano offer in 324 types of services/groups of services.
Each type of service/group of services is described, in a simple and friendly way, by means of a specific service sheet: the EC4Safenano - Service Data Sheet (EC4-SDS). These EC4-SDSs allow structuring and summarizing the information of each service, providing the customer with a concise view of characteristics of the service and also the contact details with the service provider.
The CoS 2019 deploys a map of services consisting of a set of 100 EC4-SDSs, covering 7 of the 12 Service Categories and 17 of the 27 Service Topics.
The harmonization of services is visualized as a future necessary step in EC4Safenano, in order to strengthen the offer and provide added value to customers with a growing offer of harmonized services in future versions of the CoS.
The information contained in this document is structured in 3 main sections, as follows:
• Catalogue structure. This section describes in short the main characteristics of the CoS 2019.
• Catalogue content. This section represents the core part of the document and encapsulates the set of 100 SDSs displaying the offer proposed by the CoS 2019.
• Online Catalogue. This section describes the resources implemented by EC4Safenano to facilitate the on-line consultation of the CoS 2019 by customers and other interested parties.
Recent DNA-based studies have shown that the built environment is surprisingly rich in fungi. These indoor fungi – whether transient visitors or more persistent residents – may hold clues to the rising levels of human allergies and other medical and building-related health problems observed globally. The taxo¬nomic identity of these fungi is crucial in such pursuits. Molecular identification of the built mycobiome is no trivial undertaking, however, given the large number of unidentified, misidentified, and technically compromised fungal sequences in public sequence databases. In addition, the sequence metadata required to make informed taxonomic decisions – such as country and host/substrate of collection – are often lacking even from reference and ex-type sequences. Here we report on a taxonomic annotation workshop (April 10–11, 2017) organized at the James Hutton Institute/University of Aberdeen (UK) to facilitate reproducible studies of the built mycobiome. The 32 participants went through public fungal ITS bar¬code sequences related to the built mycobiome for taxonomic and nomenclatural correctness, technical quality, and metadata availability. A total of 19,508 changes – including 4,783 name changes, 14,121 metadata annotations, and the removal of 99 technically compromised sequences – were implemented in the UNITE database for molecular identification of fungi (https://unite.ut.ee/) and shared with a range of other databases and downstream resources. Among the genera that saw the largest number of changes were Penicillium, Talaromyces, Cladosporium, Acremonium, and Alternaria, all of them of significant importance in both culture-based and culture-independent surveys of the built environment.
Compact pnCCD-based X-ray camera with high spatial and energy resolution: a color X-ray camera
(2011)
For many applications there is a requirement for nondestructive analytical investigation of the elemental distribution in a sample. With the improvement of X-ray optics and spectroscopic X-ray imagers, full field X-ray fluorescence (FF-XRF) methods are feasible. A new device for high-resolution X-ray imaging, an energy and spatial resolving X-ray camera, is presented. The basic idea behind this so-called 'color X-ray camera' (CXC) is to combine an energy dispersive array detector for X-rays, in this case a pnCCD, with polycapillary optics. Imaging is achieved using multiframe recording of the energy and the point of impact of single photons. The camera was tested using a laboratory 30 µm microfocus X-ray tube and synchrotron radiation from BESSY II at the BAMline facility. These experiments demonstrate the suitability of the camera for X-ray fluorescence analytics. The camera simultaneously records 69696 spectra with an energy resolution of 152 eV for manganese Kα with a spatial resolution of 50 µm over an imaging area of 12.7 × 12.7 mm². It is sensitive to photons in the energy region between 3 and 40 keV, limited by a 50 µm beryllium window, and the sensitive thickness of 450 µm of the chip. Online preview of the sample is possible as the software updates the sums of the counts for certain energy channel ranges during the measurement and displays 2-D false-color maps as well as spectra of selected regions. The complete data cube of 264 × 264 spectra is saved for further qualitative and quantitative processing.
REALight ‐ Leichtgranulate und REA‐Gips aus feinkörnigen sulfatbelasteten Bau‐ und Abbruchabfällen
(2023)
Ziel des Projekts REALight ist die Entwicklung einer Referenzanlage zur Herstellung von Leichtgranulaten (leichte Gesteinskörnungen) aus Bau‐ und Abbruchabfällen und zur Gipsrückgewinnung. Als Rohstoffe werden bisher ungenutzte oder auf niedrigem Niveau eingesetzte Bau‐ und Abbruchabfälle und industrielle Nebenprodukte verwendet. Als Produkte werden leichte Gesteinskörnungen hergestellt. Die Sulfatabtrennung durch eine thermische Zersetzung bildet die Grundlage für die zusätzliche Gewinnung von Rauchgasentschwefelungs‐Gips (REA‐Gips). Das Projekt wird im Rahmen der Fördermaßnahme „Ressourceneffiziente Kreislaufwirtschaft – Bauen und Mineralische Stoffkreisläufe (ReMin)” gefördert. ReMin ist eine Maßnahme zur Umsetzung des BMBF‐Forschungskonzepts „Ressourceneffiziente Kreislaufwirtschaft” als Teil der BMBF Strategie „Forschung für nachhaltige Entwicklung – FONA”. Ziel der Förderung ist es, den Ausbau der Kreislaufwirtschaft voranzutreiben. Im Mittelpunkt steht dabei die Bauwirtschaft mit ihrer hohen Nachfrage nach Rohstoffen und gleichzeitig großen Mengen an anfallenden mineralischen Abfällen. Am Projekt REALight sind 12 Partner aus verschiedenen Bereichen der Baustoffherstellung und ‐anwendung, Abfallaufbereitung, Verfahrenstechnik sowie Forschung und Entwicklung beteiligt.
A new high-resolution detector setup for neutron imaging has been developed based on infinity-corrected optics with high light collection, combined with customized mounting hardware. The system can easily be installed, handled and fitted to any existing facility, avoiding the necessity of complex optical systems or further improved electronics (CCD). This is the first time optical magnification higher than 1:1 has been used with scintillator-based neutron detectors, as well as the first implementation of infinity corrected optics for neutron imaging, achieving the smallest yet reported effective pixel size of 3.375 µm. A novel transparent crystal scintillator (GGG crystal) has been implemented with neutrons for the first time to overcome limitations of traditional powder scintillators (Li6/ZnS, Gadox). The standardized procedure for resolution measurements with the Modulation Transfer Function (MTF) is summarized to facilitate comparison between instruments and facilities. Using this new detector setup, a resolution of 14.8 µm with a field of view of 6 mm × 6 mm has been achieved while maintaining reasonable count times. These advances open a wide range of new possible research applications and allow the potential for additional future developments.
The market of the penetrant systems is increasing every year. A sensitivity of the penetrant systems is one of the main criteria for a customer. Therefore the importance of reliable result of the determination of penetrant systems sensitivity is increasing as well. It was established in our experiments that repeating the procedure of type testing in accordance with ISO EN 3452-2, in many cases one can obtain rather variable results for the sensitivity level. The goal of our investigations was to establish the principal factors, influencing upon the result of penetrant system type testing. Our results show that the values of the duration of such penetrant inspection technological stages as penetrant and developer applications may be considerably lower than the values recommended by ISO EN 3452-2 for the type testing. At the same time the character of the procedure's realisation of excess penetrant removal and developer application strongly influences upon the type testing results. Some recommendations for obtaining more reliable results of the determination of penetrant system sensitivity are worked out and proposed. ©2002 American Institute of Physics.
Apparently that the type testing procedure should be conducted under the conditions ensuring reproducibility of its outcomes. We investigated various factors effecting upon the reproducibility. To obtain quantitative characteristics of indications visibility the image-processing hard-and software were used. It was established that there are two main groups of these factors. The first depends on the differences between various test panels, which are used for type testing. The second one concerns the reproducibility of some stages of penetrant testing procedure (excess penetrant removing and developer application). The recommendations to increase the reproducibility of type testing are developed and illustrated experimentally.
The determination of penetrant system sensitivity as a part of type testing should be conducted ensuring reproducibility of the result. We investigated some factors effecting the reproducibility. To obtain quantitative characteristics of indications visibility, an image processing system was used [1]. We used 3 different sets of reference blocks (rb1, rb2, rb3) corresponding to type 1 of EN ISO 3452-3 [2]. Two fluorescent penetrants with different sensitivities and the same wet solvent developer were used.
It was established that the reproducibility of type testing is influenced by mainly two principal factors. First there are the differences between reference blocks. Second one concerns the reproducibility of penetrant testing procedure, especially excess penetrant removal and developer application.
According to EN ISO 3452-3 a reference block for determination of sensitivity level of fluorescent penetrants consists of a set of three nickel-chrome plated panels with 10, 20 and 30 µm plating thickness. Transverse cracks are made in each panel by stretching the panels in the longitudinal direction and width to depth ratio of the cracks should be approximately 1/20. Each panel presents a certain sensitivity level, which is characterised by the level of visibility of the indication. The highest level 3 corresponds to the panel with 10 µm thickness plating. Each panel is cut longitudinally (perpendicular to the crack) so that 2 sheets (panels A and B) with nearly the same cracks will be produced. These panels A and B of a reference block are used for relative evaluation, for example to compare sensitivities of two penetrants. It is considered that the application of the same penetrant to both panels with subsequent adequate development results in the same visibility of the indications on these panels.
Quantitative correlations between the abilities of the reference blocks used for determining of the sensitivity were obtained in our investigations. We used the relations between the measured values of light-fluxes from the indications of similar comparing areas on two panels. These indications correspond to certain cracks parts of the same total length on both comparing areas. The relations of the steps between the panel are responsible for the definition of the sensitivity groups. From our investigations it follows that the steps of the different sets are different. Besides it was established that the indications visibility for the same penetrant applied on different reference blocks might have a considerable difference depending on the penetrant sensitivity: the higher penetrant sensitivity, the smaller is such a difference between the steps 30/20 and 20/10. For example, for rb3 the relations 30/20 and 20/10 for lower sensitive penetrant (I1) reached factor 3 comparing with factor 2 for higher sensitive penetrant (I2).
Some results of the comparison between the 3 sets (rb1, rb2, rb3) investigations are summarised in Table 1 with rb1 as a reference.
The incorporation of colloidal quantum dots (QDs) into solid matrices, especially ionic salts, holds several advantages for industrial applications. Here, we demonstrated via absolute measurements of photoluminescence quantum yields (PL-QY) that the photoluminescence of aqueous CdTe QDs can be considerably increased upon incorporation into a salt matrix with a simple crystallization procedure. Enhancement factors of up to 2.8 and a PL-QY of 50 to 80%, both in NaCl crystals and incorporated in silicone matrices, were reached. The fact that the achievable PL enhancement factors depend strongly on PL-QY of the parent QDs can be described by the change of the dielectric surrounding and the passivation of the QD surface, modifying radiative and nonradiative rate constants. Time-resolved PL measurements revealed noncorrelating PL lifetimes and PL-QY, suggesting that weakly emissive QDs of the ensemble are more affected by the enhancement mechanism, thereby influencing PL-QY and PL lifetime in a different manner.
Bright emitters with photoluminescence in the spectral region of 800–1600 nm are increasingly important as optical reporters for molecular imaging, sensing, and telecommunication and as active components in electrooptical and photovoltaic devices. Their rational design is directly linked to suitable methods for the characterization of their signal-relevant properties, especially their photoluminescence quantum yield (Φf). Aiming at the development of bright semiconductor nanocrystals with emission >1000 nm, we designed a new NIR/IR integrating sphere setup for the wavelength region of 600–1600 nm. We assessed the performance of this setup by acquiring the corrected emission spectra and Φf of the organic dyes Itrybe, IR140, and IR26 and several infrared (IR)-emissive Cd1-xHgxTe and PbS semiconductor nanocrystals and comparing them to data obtained with two independently calibrated fluorescence instruments absolutely or relative to previously evaluated reference dyes. Our results highlight special challenges of photoluminescence studies in the IR ranging from solvent absorption to the lack of spectral and intensity standards together with quantum dot-specific challenges like photobrightening and photodarkening and the size-dependent air stability and photostability of differently sized oleate-capped PbS colloids. These effects can be representative of lead chalcogenides. Moreover, we redetermined the Φf of IR26, the most frequently used IR reference dye, to 1.1 × 10-3 in 1,2-dichloroethane DCE with a thorough sample reabsorption and solvent absorption correction. Our results indicate the need for a critical reevaluation of Φf values of IR-emissive nanomaterials and offer guidelines for improved Φf measurements.
DICONDE (Digital Imaging and Communication in Non-Destructive Testing) is an open international standard for storing and exchanging industrial test data and process-related information. The DICONDE standard defines both the semantics for structured storage of data and the network-based communication between two endpoints. This allows many test processes to be mapped digitally and securely, while at the same time meeting normative requirements such as traceability to the tester and test object and reproducibility of test results.
The development of traceable new methodologies to quantify elemental air pollutants in particulate matter (PM) supports modernization of methods used in air quality monitoring networks in Europe. In the framework of the EURAMET EMPIR AEROMET II project, the combination of cascade impactor aerosol sampling and total reflection X-ray fluorescence elemental spectroscopy (TXRF) was investigated. This technique requires a traceable calibration based on reference samples. This paper describes a new, simple and effective method to produce such reference samples using flexible, reusable, and low-cost parylene C shadow masks, fabricated by photolithographic steps. These shadow masks can be used to produce reference samples that mimic the Dekati cascade impactor’s deposition patterns by applying as-prepared micro stencils to 30 mm acrylic substrates and evaporating a reference material (Ti) in arrangements of thin circular dots. The highly flexible direct patterning of acrylic discs with reference material, otherwise impossible with conventional photolithography, allows multiple reusing of the same micro stencils. The aspect ratios of the dots could be repeated with an error less than 4 %. A first set of standard reference samples for the 13 stages of the Dekati cascade impactor was produced and preliminary TXRF measurements of the deposited Ti masses were performed. The centricity of the deposition patterns turned out to be an important parameter for the quality of the TXRF results. The parylene mask technology for the production of reference samples turns out to be a promising new approach for the traceable calibration of TXRF spectrometers for the quantification of element concentrations in environmental aerosol samples but, due to its great versatility, it could be used for several other micropatterning applications on conventional and unconventional substrates.
Im deutschen Eisenbahnnetz sind ca. 80 Millionen Spannbetonschwellen verbaut. Analog zu anderen Bauwerken werden Wpannbetonschwellen regelmäßig visuell inspiziert. Die Rissbildung ist bei diesen Inspektionen ein Kriterium für die Schädigung einer Spannbetonschwelle. Durch Rissbildung kann es passieren, dass Betonschwellen ihre Nutzungsdauer nicht erreichen.
The development of earth-abundant catalysts for selective electrochemical CO2 conversion is a central challenge. Cu-Sn bimetallic catalysts can yield selective CO2 reduction toward either CO or formate. This study presents oxide-derived Cu-Sn catalysts tunable for either product and seeks to understand the synergetic effects between Cu and Sn causing these selectivity trends. The materials undergo significant transformations under CO2 reduction conditions, and their dynamic bulk and surface structures are revealed by correlating observations from multiple methods—X-ray absorption spectroscopy for in situ study, and quasi in situ X-ray photoelectron spectroscopy for surface sensitivity. For both types of catalysts, Cu transforms to metallic Cu0 under reaction conditions. However, the Sn speciation and content differ significantly between the catalyst types: the CO-selective catalysts exhibit a surface Sn content of 13 at. % predominantly present as oxidized Sn, while the formate-selective catalysts display an Sn content of ≈70 at. % consisting of both metallic Sn0 and Sn oxide species. Density functional theory simulations suggest that Snδ+ sites weaken CO adsorption, thereby enhancing CO selectivity, while Sn0 sites hinder H adsorption and promote formate production. This study reveals the complex dependence of catalyst structure, composition, and speciation with electrochemical bias in bimetallic Cu catalysts.
In this study, a multi-proxy approach combining 29Si, 27Al and 1H MAS-NMR, FEG-EPMA, XANES at the Cu K-edge and XRD analytics with hydrochemical tools such as ICP-OES analyses, oxygen-isotope signatures, and thermodynamic modelling was applied to K-silicate-activated metakaolin specimens - with and without CuSO4·5H2O addition - exposed to sulfuric acid at pH = 2 for 35 days. The results revealed a multistage deterioration mechanism governed by (i) acid diffusion, (ii) leaching of K-A-S-H, (iii) microstructural damage related to precipitation of expansive (K,Ca,Al)-sulfate-hydrate phases (iv) complete dissolution of the K-A-S-H framework, (v) and formation of silica gel in the outermost corroded regions. Copper ions were mainly located in layered spertiniite-chrysocolla-like phases in the as-cured materials. The results demonstrate an overall negative effect of Cu addition on chemical material durability, implying that the reported higher durability of Cu-doped AAM in biocorrosion environments can be best explained by bacteriostatic effects.
Die Empfindlichkeit von Eindring- und Magnetpulverprüfungen (PT, MT) hängt unter anderem von der Eignung und der Qualität der Prüfmittel ab (für PT bezeichnet als Eindringsystem). Die Ermittlung der Empfindlichkeit erfolgt an Kontrollkörpern mit natürlichen und künstlichen Inhomogenitäten durch Ermittlung der Anzeigenerkennbarkeit als Maß für die Eignung. Die europäischen Normen spezifizieren die Anforderungen an die Prüfmittel für Typen-, Chargen- und Betriebsprüfungen nach pr EN ISO 3452-2 für PT und EN ISO 9934-2 für MT. Dieser Beitrag beschreibt die Ermittlung der Empfindlichkeit von Prüfmitteln sowie deren Qualifizierung bei der Typenprüfung. Die vorgeschlagenen Verfahren wurden durch experimentelle Untersuchungen validiert, bei denen ein Bildverarbeitungssystem zur Ermittlung der Anzeigenerkennbarkeit verwendet wurde. Im Hinblick auf die Qualifizierung der Prüfmittel wird die Zuverlässigkeit der Verfahren diskutiert.