Filtern
Erscheinungsjahr
Dokumenttyp
Referierte Publikation
- ja (63) (entfernen)
Schlagworte
- Gas storage areas (9)
- Membrane-based gas sensing (9)
- Subsurface monitoring (9)
- Autonomous micro UAV (5)
- Gas source localization (5)
- Distributed linear sensor (4)
- Distributed sensor (4)
- Electronic nose (4)
- Embedded sensors (4)
- Nanocomposites (4)
Organisationseinheit der BAM
- 8 Zerstörungsfreie Prüfung (17)
- 8.1 Sensorik, mess- und prüftechnische Verfahren (17)
- 1 Analytische Chemie; Referenzmaterialien (5)
- 1.9 Chemische und optische Sensorik (4)
- 8.2 Zerstörungsfreie Prüfmethoden für das Bauwesen (2)
- 1.2 Biophotonik (1)
- 8.0 Abteilungsleitung und andere (1)
- VP Vizepräsident (1)
- VP.2 Informationstechnik (1)
Paper des Monats
- ja (1)
This paper describes a wireless mobile prototype able to perform optical measurements by means of a miniatur-ized spectrometer for low light analysis, e.g. fluorescent sensors. Evaluations, calculations, calibration management and result display are performed by a computer or a standard tablet. The device was designed primarily to detect traces of oil in drinking or ground water and for the analyses of crude oils. However, it can also address a wide range of fluorescent sensors. The fast and user-friendly inspection of water quality or oil properties, as well as the adaptability and mobility, make the device attractive for a variety of users. Further application areas could be easily imple-mented by adapting the optics and the software (database, data processing and calibration plots, etc.)
The presence of wastewater and air pollution has become an important risk factor for citizens, not only in terms of problems related to health risks, but also because of its negative impact on the country's image. For this reason, malodorous emission monitoring and control techniques are in high demand in urban areas and industries. The aim of this work is first to build an electronic nose (e-nose) and a Voltammetric Electronic tongue (VE-tongue) in order to study their ability to discriminate between polluted and clean environmental samples. Secondly, Thermal Desorption-Gas Chromatography-Mass Spectrometry (TD-GC-MS), and Solid Phase Micro Extraction-Gas Chromatography–Mass Spectrometry (SPME-GC-MS) are utilized to explain this discrimination by identifying specific compounds from these samples. Indeed, the e-nose, consisted of metal oxide semiconductor gas sensors, is used for the assessment of the studied odorous air and headspace samples from water and wastewater sites. Moreover, the VE-tongue, based on metal electrodes, is utilized to determine the patterns of the sensor array responses, which serve as fingerprints profiles of the analyzed liquid samples. Chemometric tools, such as Principal Component Analysis (PCA), Hierarchical Cluster Analysis (HCA), and Support Vector Machines (SVMs) are operated for the processing of data from the e-nose and the VE-tongue. By using the both systems, the analyses of headspace and liquid samples from the seven sites allow better discrimination. To explain the cause of the obtained discrimination, TD-GC-MS and SPME-GC-MS analyses are well performed to identify compounds related sites. According to these outcomes, the proposed e-nose and VE-tongue are proved to be rapid and valuable tools for analysis of environmental polluted matrices.
A 400 m2 soil test field with gas injection system was built up, which enables an experimental validation of linear membrane-based gas sensors – a sensor technology which was developed based on the selective permeation of gases through membranes. Several soil watering and injection experiments with carbon dioxide at different days with varying boundary conditions were performed showing that the sensor behaves mostly insensitive to the environmental conditions investigated, i.e., barometric pressure fluctuations, soil temperature, air temperature and humidity, sun duration, and wind speed. Furthermore, depending on water infiltration, a gas phase displacement could be observed in-situ based on the changed measurement signal. The results of the validation experiments highlight the potential of the method for rapid leak detection and localization qualifying the sensor particularly for safety applications, e.g., in underground gas storage areas.
The applicability of three methods developed by finite element analysis (FEM) and proposed in the literature are studied on steel S355. Instrumented indentation tests using spherical indenters of radius 200 and 500 μ m are performed in the macro range at depths of more than 6 μ m. The results of the selected methods are compared with the tensile test. To evaluate the partially strongly varying results, the uncertainties of the calculated strain hardening exponent, n, and yield stress, Y, are estimated. Recommendations for an appropriated procedure of the indentation test are given. The machine compliance and the determination of the zero point of Depth play an essential role. If the certain conditions are considered, the instrumented indentation Tests can be used, in particular for investigations of specimens with inhomogeneous elastoplasticity.
Completely embedded sensor systems for long-term
operation offer innovative possibilities for structural health
monitoring of concrete structures. Measuring of relevant
parameters, e.g., temperature, humidity, or indication of
corrosion can be performed with low energy sensors. This allows
to implement passive RFID sensor systems without cable
connection and battery, which are power supplied exclusively by
the electromagnetic field from the external reader device. To
evaluate characteristics and conditions of this concept, a
systematical investigation of the transmission characteristics with
variation of relevant parameters, as communication frequency,
installation depth, type of concrete, moisture content, etc. is
currently carried out in an interdisciplinary research project at
BAM. First results are presented in this paper.
A monitoring method is introduced that creates twodimensional (2D) maps of the soil gas distribution. The method combines linear gas sensing technology for in-situ monitoring of gases in soil with the mapping capabilities of Computed Tomography (CT) to reconstruct spatial and temporal resolved gas distribution maps. A weighted iterative algebraic reconstruction method based on Maximum Likelihood with Expectation Maximization (MLEM) in combination with a source-by-source reconstruction approach is introduced that works with a sparse setup of orthogonally-aligned linear gas sensors. The reconstruction method successfully reduces artifact production, especially when multiple gas sources are present, allowing the discrimination between true and non-existing so-called ghost source locations. Experimental validation by controlled field experiments indicates the high potential of the proposed method for rapid gas leak localization and quantification with respect to Pipeline or underground gas storage issues.
Thermogravimetry (TG), thermogravimetry coupled with mass spectroscopy (TG-MS) and thermogravimetry coupled with Fourier transform infrared spectroscopy (TG-FTIR) were used to characterise the thermo-oxidative behaviour of two intumescent coating materials. The temperature dependence, the corresponding volatile products and the amount of residue of the different processes were determined. Using both TG-MS and TG-FTIR results in an unambiguous interpretation of the volatile products. Characteristics such as the influence of endothermic reactions, the release of non-flammable gases, the dehydrogenation enhancing the char formation and the stability of the cellular char were discussed in detail. It was demonstrated, that TG, TG-MS and TG-FTIR are powerful methods to investigate mechanisms in intumescent coatings and that they are suitable methods in respect to quality assurance and unambiguous identification of such materials.
The cone calorimeter has become one of the most important and widely used instruments for the research and development of fire retarded polymeric materials. The paper addresses three important ways in which the principal setup influences the results factors which sometimes do not receive due consideration when drawing conclusions. The paper discusses in detail the impact on cone calorimeter results of the choice of external heat flux, the influence on the peak of heat release rate of sample thickness and thermal feedback from the back of the sample, and the influence on irradiance of the horizontal and vertical distances from the cone heater.
Barrier formation and increasing the melt viscosity are addressed as the two main general fire retardancy mechanisms of polymer nanocomposites. They result in specific impacts on fire properties that consequentially cause varying flame retardancy efficiency in different fire tests. The barrier formation retards mainly flame spread (peak of heat release rate) in developing fires, but does not reduce fire load (total heat evolved), ignitability or flammability (limiting oxygen index, UL 94). Furthermore, this flame retardancy effect increases with increasing irradiation and vanishes with decreasing irradiation. The increased melt viscosity prevents dripping, which is beneficial or disadvantageous depending on the fire test used. In some test, it become the dominant influence, transforming self-extinguishing samples into flammable materials or causing wicking. Advantages and the limits are sketched comprehensively for exploiting the main general fire retardancy mechanisms of polymer nanocomposites. It is concluded that barrier formation and changing the melt viscosity in nanocomposites are not sufficient for most applications, but must be accompanied by additional mechanisms in special systems or in combination with other flame retardants.
In civil engineering, many structures are made of reinforced concrete. Most Degradation processes relevant to this material, e.g., corrosion, are related to an increased level of material moisture.
Therefore, moisture monitoring in reinforced concrete is regarded as a crucial method for structural health monitoring. In this study, passive radio frequency identification (RFID)-based sensors are embedded into the concrete. They are well suited for long-term operation over decades and are well protected against harsh environmental conditions. The energy supply and the data transfer of the humidity sensors are provided by RFID. The sensor casing materials are optimised to withstand the high alkaline environment in concrete, having pH values of more than 12. Membrane materials are also investigated to identify materials capable of enabling water vapour transport from the porous cement matrix to the embedded humidity sensor. By measuring the corresponding relative humidity with embedded passive RFID-based sensors, the cement hydration is monitored for 170 days.
Moreover, long-term moisture monitoring is performed for more than 1000 days. The Experiments show that embedded passive RFID-based sensors are highly suitable for long-term structural health monitoring in civil engineering.