Because the demining process is always connected with a danger for human beings, it is necessary to make sure the proper functioning of mine searching equipment in detecting mines. Detecting a hidden target by penetrating physical interaction of rays or waves is similar to non-destructive testing. The non-destructive testing profession developed procedures to check the reliability of testing. These procedures, like the performance demonstration where the successful detections are statistically evaluated against false call rates and their implementation in an industrial standard (ASME section XI appendix VIII) are used as a template. A first adoption to demining was accomplished in the prescription for blind trials in the CEN workshop agreement CWA 14747: 2003 for test and evaluation of metal detectors. Within an ITEP project a number of blind trials were carried out to learn about the necessary statistical basis of those trials to achieve true, reproducible and repeatable results to give guidance for the selection and improvement of metal detectors. The special focus in this first investigation was on the influence of the human factor due to the different degree of experience of the operators and the influence of the soil.
Polypropylene based ferroelectret films exhibit a strong electromechanical activity and provide a promising solution for the air coupled ultrasonic (ACUS) transducers. Ultrasonic transmission between two air coupled ferroelectret transducers in dependence on the amplitude and polarity of the high voltage exciting pulse revealed a strongly non-linear electromechanical response of the ferroelectret transmitter which provides an increase in the transmitter efficiency. The authors present a simple model describing both promotion and competition of the piezoelectric and electrostriction contributions, as well as increase in the transducer constant under high voltage excitation. Enlargement of the inverse transducer constant of the polypropylene ferroelectret film by a factor of 4 was demonstrated. The non-linear properties of the polypropylene ferroelectrets result in a strong increase in their ACUS figure of merit under the high voltage excitation, which exceeds the results of their technological optimisation. Consequently, enhancement of the ACUS system transmission by 12 dB and signal to noise ratio by 32 dB was achieved.
Für die luftgekoppelte Ultraschall-Prüfung wird der Prototyp eines neuartigen Prüfkopfes vorgestellt. Statt eines piezokeramischen Ultraschall-Wandlers mit einer λ/4-Anpassschicht wird eine Ferroelektret-Folie aus schaumförmigem Polypropylen eingesetzt. Durch die außerordentlich geringe akustische Impedanz der Folie reduzieren sich die Reflexionsverluste an den Grenzschichten zur Luft so stark, dass bei diesem Prüfkopf auf eine λ/4-Anpassschicht verzichtet werden kann. Außerdem ist die Folie hochspannungsfest. Sie konnte mit Spannungen von mehr als 3500 V angesteuert werden und erlaubte eine Vorspannung am Ultraschall-Wandler des Empfangsprüfkopfes von 2000 V. Mithilfe der hohen Anregungsspannung stieg die Amplitude des akustischen Prüfimpulses auf das 11,2-Fache. Die Empfindlichkeit des Empfängers erhöhte sich durch die Vorspannung weiter um den Faktor 4,3. Insgesamt steigt die Amplitude am Empfänger also auf das 48-Fache, bei gleichbleibendem Rauschpegel. Ein abschließender Vergleich mit kommerziellen Luftultraschall-Prüfköpfen belegt die Überlegenheit der Folien-Prüfköpfe. Damit rückt der Einsatz einer vollwertigen Impuls-Echo-Technik auch bei der luftgekoppelten Ultraschallprüfung deutlich näher.
The total reliability of a mine searching system is driven by the triple of intrinsic
capability, which describes the physical-technical basis capability, the application and
environmental factors and the human factors. Some of them can be determined in
laboratory measurements but the human factor and a part of environment conditions
and their interaction with the device need to be treated statistically. That is why the
test & evaluation procedure described in CEN CWA 14747:2003, includes in addition
to parameter tests of metal detectors also the reliability or blind field tests under local
conditions with local personnel. A series of three big field trials had been
accomplished in the ITEP-project 2.1.1.2 Reliability Model for Test & Evaluation of
Metal Detectors to specify the optimum conditions for reliable trial results with
affordable effort. For each set of specific working conditions, characterized in terms
of a combination of one mine type in one soil with one detector handled by local
personnel, the searching system will show up a working performance in mine
detection rates as a function of mine depth and show up a certain overall false call
rate. During the ITEP-trials in Benkovac and Oberjettenberg the authors learnt to
determine this function separately for each mine type in each soil, which is especially
important for low metal mines in uncooperative soil which will be illustrated for the
mine PMA2 in different types of soil. The question of representativeness for field
conditions on the one hand and necessary statistical set up for the possibility to
distinguish between individual detector performances is still under discussion.
Electromechanical response of polypropylene ferroelectret transducers under application of high-voltage pulses was measured by laser Doppler vibrometry and compared with results of ultrasonic through-air transmission between two ferroelectret transducers. The electromechanical response was completely explained by piezoelectric and electrostrictive effects. The electrostrictive effect dominates at high voltages and provides significant enlargement of the transducer constant, up to factor of 2.5. The induced strain of 1.7% was achieved at – 2000 V. The nonlinear ultrasonic transmission was shown to be well described by the piezoelectric and electrostrictive response of transmitter, except in the range of high negative exciting voltages where some limitation of the transmitted signal was observed. This limitation seems not to be a fundamental one and does not abolish the advantages of high-voltage excitation of polypropylene ferroelectret transducers.
The human factors approach relies on understanding the properties of human capability and limitations under various conditions and the application of that knowledge in designing and developing safe systems. Following the principles of the MTO (Man Technology Organisation) approach, emphasis should be given to the way people interact with technical as well as organisational systems.
A model describing human factor influences in relation to the performance shaping factors and their effect on manual ultrasonic inspection performance had been built and a part of it empirically tested. The experimental task involved repeated inspection of 18 defects according to the standard procedure under no, middle and high time pressure. Stress coping strategies, the mental workload of the task, stress reaction and organisational factors have been measured. The results have shown that time pressure, mental workload and experience influence the quality of the inspection performance. Organisational factors and their influence on the inspection results were rated as important by the operators. However, further research is necessary into the effects of stress.
Ultrasonic probes for high-temperature applications are provided with metallic wedges, which can withstand the contact with the high temperature of the inspected structure. The ultrasonic signal travels within the wedge and gets reflected from its boundaries, causing interference signals called “ghost echoes”. The current work presents an investigation of the additional damping effect provided by porous sintered metal plates applied onto the surface of the wedge. In particular, the study evaluates the effect of damping plate thickness on the interference signal level at different transmission frequencies. Damping plates made of sintered metal SIKA-R 15 AX were attached to a wedge prototype made of steel 1.4301. The study revealed, that the most effective thickness of damping plates in the selected frequency interval of 1 to 4 MHz is equal to 4 mm. The evaluation of the interference signal has shown that the application of such damping plates to the wedge surface contributes to an additional attenuation of an interference signal of 10 to 30 dB after 500 μs of signal propagation.
Viscoelastic properties of cellular polypropylene ferroelectrets (PP FEs) were studied at low
frequencies (0.3–33 Hz) by dynamic mechanical analysis and at high frequencies (250 kHz) by laser Doppler vibrometry. Relaxation behavior of the in-plane Young’s modulus (Y´
11~1500 MPa at room temperature) was observed and attributed to the viscoelastic response of polypropylene matrix.
The out-of-plane Young’s modulus is very small (Y´33≈0.1 MPa) at low frequencies, frequency- and stress-dependent, evidencing nonlinear viscoelastic response of PP FEs. The highfrequency mechanical response of PP FEs is shown to be linear viscoelastic with Y´33≈0.8 MPa. It is described by thickness vibration mode and modeled as a damped harmonic oscillator with one degree of freedom. Frequency dependence of Y*33 in the large dynamic strain regime is described by the broad Cole-Cole relaxation with a mean frequency in kHz range attributed to the Dynamics of the air flow between partially closed air-filled voids in PP FEs. Switching-off the relaxation contribution causes dynamic crossover from the nonlinear viscoelastic regime at low frequencies to the linear viscoelastic regime at high frequencies. In the small strain regime, contribution of the air flow seems to be insignificant and the power-law response, attributed to the mechanics of polypropylene cell walls and closed air voids, dominates in a broad frequency range. Mechanical Relaxation caused by the air flow mechanism takes place in the sound and ultrasound frequency range (10 Hz–1MHz) and, therefore, should be taken into account in ultrasonic applications of the PP FEs deal with strong exciting or receiving signals.