Filtern
Erscheinungsjahr
Dokumenttyp
- Vortrag (18)
- Zeitschriftenartikel (6)
- Beitrag zu einem Tagungsband (4)
- Posterpräsentation (3)
Sprache
- Deutsch (31) (entfernen)
Schlagworte
- Feuerwiderstand (2)
- Berechnungs- und Bemessungsverfahren (1)
- Brandschutz (1)
- EC (1)
- Eurocode (1)
- Feuerwiderstandsdauer (1)
- Finite-Elemente-Methode (1)
- Hochfester Beton (1)
- Hochleistungsbeton (1)
- Hybride Versuchstechnik (1)
Eingeladener Vortrag
- nein (18)
Thermal Restraint Effects on the Fire Resistance of Steel Composite Steel and Concrete Columns
(2009)
Thermal Restraint Effects on the Fire Resistance of Steel and Composite Steel and Concrete Columns
(2009)
Substrukturtechnik: Eine hybride Prüfmethode. Überblick mit Anwendung im Brandingeniueurwesen
(1999)
Substrukturtechnik - eine hybride Prüfmethode ; Überblick mit Anwendung im Brandingenieurwesen
(1999)
For the evaluation of the fire resistance time of structural elements thermal and mechanical loadings are applied to the specimen. Up to now the monitored data is represented in tabular form and simple plots. In the following a visualization system to show the data in its geometrical context is discussed.
Isotrope nichtlineare Viskoelastizität mit Hilfe von Maßstabsfunktionen der Gedächtnisspannung
(1993)
Isotrope nichtlineare Viskoelastizität mit Hilfe von Maßstabsfunktionen der Gedächtnisspannung
(1994)
Experimental and numerical study of high performance concrete columns subjected to fire loading
(2009)
Experimental and numerical study of high performance concrete columns subjected to fire loading
(2009)
Ausgehend von einer kritischen Analyse der Materialkennwerte für normalfesten (NFB) und hochfesten Beton (HFB) im Eurocode 2 wurden in grundlegenden Untersuchungen an der BAM exemplarisch für einen HFB die thermomechanischen Materialkennwerte bestimmt, um auf der Basis eines geeigneten Materialmodells das Verhalten von Stahlbetonstützen aus HFB unter Brandbeanspruchung zu simulieren. Die Validierung des Modells erfolgte mittels großmaßstäblicher Brandversuche an belasteten Stahlbetonstützen aus dem gleichen HFB wie in den Materialuntersuchungen. Es konnte gezeigt werden, dass die Festigkeit als charakteristischer Parameter des Materialmodells zwingend auf der Basis instationärer Versuche und nicht aus stationären Versuchen wie bei NFB üblich bestimmt werden muss. Mit den in vorgeschlagenen Materialbeziehungen für HFB wird das Tragverhalten der untersuchten Stützen dagegen deutlich überschätzt, was sich in den numerischen Simulationen insbesondere durch zu geringe Verformungen äußert.------------------------------------------------------------------------------------------------------
Development and Validation of an Advanced Calculation Model for High Strength Concrete Columns Subjected to Fire Loading
Following a critical analysis of the material parameters of normal strength (NSC) and high strength concrete (HSC) presented in Eurocode 2 the thermo-mechanical material parameters of one representative HSC were identified. Using these parameters and based on an appropriate material model the behavior of HSC columns was simulated. The validation of the model was realized through real scale fire resistance tests on loaded columns of the same type of HSC as in the material identification tests. It was found that the strength as a characteristic parameter of the material model has to be identified on the basis of transient creep tests and not of stationary tests, respectively as realized usually for NSC. It could be shown that the structural behavior of the tested columns is overestimated if the numerical simulations are based on the material properties of HSC as proposed in. This feature is expressed especially through insufficient displacements.
In klassischen Feuerwiderstandsprüfungen wird die Tragfähigkeit eines einzelnen Tragwerkselementes (z. B. Stütze) unter Feuereinwirkung bestimmt. In realen Brandsituationen interagieren jedoch brandbeanspruchte Bauteile eines Gebäudes immer mit dem angrenzenden Tragwerk. Für eine genauere Bewertung der Tragfähigkeit werden deshalb spezielle experimentelle Methoden benötigt, die eine Interaktion zwischen geprüftem Bauteil und Tragwerk in Feuerwiderstandsprüfungen berücksichtigen.
Zur Umsetzung dieses Anspruchs konnte in Kooperation mit dem Joint Research Centre (JRC) in Ispra, Italien, die bereits im Erdbebeningenieurwesen eingesetzte Substrukturmethode erfolgreich zur innovativen Nutzung des Stützenprüfofens der BAM portiert werden. Nach dieser Methode wird das gesamte Gebäude in zwei Teile zerlegt: Ein Teil entspricht dem zu prüfenden Bauteil, während der Rest des Gebäudes online durch ein analytisches oder numerisches Modell simuliert wird.
Im Vortrag werden entsprechende Ergebnisse zahlreicher Experimente neben Erläuterungen zu Hard- und Software präsentiert. Abschließend werden weitere Forschungsaktivitäten des Fachbereiches Brandingenieurwesen vorgestellt.