Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (22) (entfernen)
Schlagworte
- Fire resistance (4)
- Fire stability (3)
- Fully developed fire (3)
- Concrete (2)
- Berechnungs- und Bemessungsverfahren (1)
- Brandschutz (1)
- Buckling (1)
- Carbon fiber reinforced polymer (CFRP) (1)
- Carbon-fibre-reinforced (1)
- Carbon-fibre-reinforced plastics (1)
- Circular (1)
- Column (1)
- Composite (1)
- Composite steel-concrete columns (1)
- Composites (1)
- Concrete filled tube (CFT) column (1)
- Core materials (1)
- Design temperatures (1)
- Dry film thickness (1)
- EC (1)
- Eurocode (1)
- Feuerwiderstand (1)
- Feuerwiderstandsdauer (1)
- Finite element analysis (1)
- Finite-Elemente-Methode (1)
- Fire (1)
- Fire protective coatings (1)
- Fire resistance period (1)
- Fire spalling (1)
- Fire testing (1)
- Glass-fibre-reinforced plastics (1)
- High-temperature properties (1)
- Hochfester Beton (1)
- Hochleistungsbeton (1)
- Intumescence (1)
- Intumescent coating (1)
- Large scale tests (1)
- Mechanical testing (1)
- Modellierung (1)
- Multi-hazard incident (1)
- Nichtlineare Berechnungsverfahren (1)
- Normen (1)
- Normen/Vorschriften/Richtlinien (1)
- Post-crash scenario (1)
- Post-earthquake fire (1)
- Reaktive Brandschutzsysteme (1)
- Resistance (1)
- Restraining (1)
- Restraining frame (1)
- Seismically damaged column (1)
- Stahl (1)
- Standardised fire resistance tests (1)
- Steel beams and columns (1)
- Stickability (1)
- Structural integrity (1)
- Substructuring method (1)
- Thermal restraint (1)
- Thermogravimetric analyses (1)
- Thermomechanical properties (1)
- Verformungsverhalten (1)
- Versuche (1)
- Weathering (1)
Organisationseinheit der BAM
The composite steel and concrete columns are known to have enhanced fire behaviour when compared with bare steel columns. However there are still aspects that must be clarified, as the influence of the building surrounding structure on the fire resistance of the columns. In this paper, the results of fire resistance tests on partially encased steel columns carried out with two different experimental systems are compared. In one of the experimental systems, the building surrounding structure is materialised by a steel restraining frame, and in the other is performed by the so-called substructuring method. Due to the concept of hybrid substructuring, the entire building is decomposed in two parts: one is represented by the building element under test, whereas the remaining building is simulated numerically in a computer. The main conclusion drawn from this work was that the surrounding structure has a major influence in the development of axial forces in the test columns. Moreover, it was observed that the higher the non-dimensional axial restraint ratio the lower the critical time of the columns.