Issues that prevent Structural Health Monitoring (SHM) based on Guided Waves (GW) from being a part of today’s monitoring solutions in industry are not all obvious to the scientific community. To uncover and overcome these issues, scientists working on SHM and GW problems joined in an expert committee under the patronage of the German Society for Non-Destructive Testing. An initiated online survey among more than 700 experts and users reveals the hurdles hindering the practical application of GWbased SHM. Firstly, methods for proof of reliability of SHM approaches are missing.
Secondly, detailed understanding of phenomenological described wave-damage interactions is needed. Additionally, there are significant unsolved implementation issues and unsolved problems of signal processing including handling of environmental influences.
To enable substantial proof of reliability without unaffordable experimental effort also efficient simulation tools including realistic damage interaction are needed, enabling the joint use of experimental and simulated data to predict the capabilities of the Monitoring system. Considering these issues, the committee focusses on simulation, signal processing, as well as probability of detection and standardization. In the presented work, recent activities of the expert committee starting with survey results are summarized. An open access data basis of life-like measurements is presented to allow testing and comparison of signal processing and simulation algorithms. Finally, a strategy for efficient proof of reliability increasing the acceptance of SHM in industry and for successful Integration of SHM into real-world engineering structures is proposed.
This report describes the methodology of the reliability investigation performed on the ultrasonic
phased array NDT system, developed by SKB in collaboration with Posiva, for inspection of the
canisters for permanent storage of nuclear spent fuel.
The canister is composed of a cast iron insert surrounded by a copper shell. The shell is composed
of the tube and the lid/base which are welded to the tube after the fuel has been place, in the
tube. The manufacturing process of the canister parts and the welding process are described.
Possible defects, which might arise in the canister components during the manufacturing
or in the weld during the welding, are indentified.
The number of real defects in manufactured components have been limited. Therefore the reliability
of the NDT system has been determined using a number of test objects with artifical defects.
The reliability analysis is based on the signal response analysis. The conventional signal response
analysis is adopted and further developed before applied on the modern ultrasonic phased-array
NDT system. The concept of multi-parameter a, where the response of the NDT system is dependent
on more than just one parameter, is introduced. The weakness of use of the peak signal response
in the analysis is demonstrated and integration of the amplitudes in the C-scan is proposed as an
alternative. The calculation of the volume POD, when the part is inspected with more configurations,
is also presented. The reliability analysis is supported by the ultrasonic simulation based on the
point source synthesis method.
In many industrial sectors, Structural Health Monitoring (SHM) is considered as an addition to Non-Destructive Testing (NDT) that can reduce maintenance effort during lifetime of a technical facility, structural component or vehicle. A large number of SHM methods is based on ultrasonic waves, whose properties change depending on structural health. However, the wide application of SHM systems is limited due to the lack of suitable methods to assess their reliability. The evaluation of the system performance usually refers to the determination of the Probability of Detection (POD) of a test procedure. Up to now, only few limited methods exist to evaluate the POD of SHM systems, which prevent them from being standardised and widely accepted in industry. The biggest hurdle concerning the POD calculation is the large amount of samples needed. A POD analysis requires data from numerous identical structures with integrated SHM systems. Each structure is then damaged at different locations and with various degrees of severity. All of this is connected to high costs. Therefore, one possible way to tackle this problem is to perform computer-aided investigations. In this work, the POD assessment procedure established in NDT according to the Berens model is adapted to guided wave-based SHM systems. The approach implemented here is based on solely computer-aided investigations. After efficient modelling of wave propagation phenomena across an automotive component made of a carbon fibre-reinforced composite, the POD curves are extracted. Finally, the novel concept of a POD map is introduced to look into the effect of damage position on system reliability.