Filtern
Erscheinungsjahr
Dokumenttyp
- Beitrag zu einem Tagungsband (36)
- Vortrag (30)
- Zeitschriftenartikel (15)
- Buchkapitel (9)
- Posterpräsentation (3)
- Beitrag zu einem Sammelband (1)
Sprache
- Englisch (57)
- Deutsch (34)
- Mehrsprachig (2)
- Italienisch (1)
Schlagworte
- Earthen materials (9)
- Rammed earth (8)
- Earth block masonry (7)
- Diagonal compression test (6)
- Baustoffe (5)
- Strengthening (5)
- Autoclaved aerated concrete (AAC) (4)
- Lehmbau (4)
- Shear behaviour (4)
- Ultra-high performance concrete (UHPC) (4)
- Anchor pins (3)
- Building Materials (3)
- Building materials (3)
- Cellular lightweight concrete (CLC) (3)
- Composite panels (3)
- Compression behaviour (3)
- Compression test (3)
- Masonry tower (3)
- Seismic assessment (3)
- Uniaxial compression test (3)
- Adobe masonry (2)
- Ambient vibration tests (2)
- Cob (2)
- Compressive strength (2)
- Cultural heritage (2)
- Digital image correlation (2)
- Dynamic characterisation (2)
- Earth block (2)
- Earth construction (2)
- Earth masonry (2)
- Earthen Materials (2)
- Einpressmörtel (2)
- Finite element method (2)
- Grout mortar (2)
- Grouting (2)
- Historical buildings (2)
- Historische Bauwerke (2)
- Hydraulic lime (2)
- Initial shear strength (2)
- Instandsetzung (2)
- Kalkhydrat (2)
- Lehmmauerwerk (2)
- Lehmsteinmauerwerk (2)
- Masonry towers (2)
- Material test (2)
- Mechanical behaviour (2)
- Mechanische Eigenschaften (2)
- Numerical modelling (2)
- Polyester fabric strips (2)
- Pull-out tests (2)
- Repair (2)
- Shear Behaviour (2)
- Shear strength (2)
- Shear-compression tests (2)
- Stampflehm (2)
- Standards (2)
- Structural identification (2)
- ambient vibration tests (2)
- dynamic characterisation (2)
- masonry towers (2)
- rammed earth (2)
- seismic assessment (2)
- AAC (1)
- Adhesion (1)
- Adobe (1)
- Aerogel (1)
- Ambient vibration measurements (1)
- Ankerauszugsversuche (1)
- Ankertraglast (1)
- Archaeology (1)
- Autoclaved aerated concrete (1)
- Bemessung (1)
- Bond strength (1)
- Brick masonry (1)
- Brickwork masonry (1)
- Cellular lightweight concrete ^ (1)
- Composite UHPC elements (1)
- Compressed earth blocks (1)
- Compression Behaviour (1)
- Compression and shear testing (1)
- Compression behavior (1)
- Crack pattern (1)
- Cracks (1)
- Cracks grouting (1)
- Cracks repair (1)
- Cultural Heritage protection (1)
- Cyclic tests (1)
- Cyclinc loading (1)
- Diagonal compression tests (1)
- Diagonal-compression (1)
- Digital Image Correlation (1)
- Digital image corelation (1)
- Disaster risk reduction strategies (1)
- Druck- und Schubbeanspruchung (1)
- Druck- und Schubprüfung (1)
- Druckfestigkeit (1)
- Druckversuche (1)
- Dynamic identification (1)
- Dynamic loads (1)
- Earth block masonry (EBM) (1)
- Earth blocks (1)
- Earth mortar (1)
- Earthen Structures (1)
- Earthen architecture (1)
- Earthen building materials (1)
- Earthen construction (1)
- Emission testing (1)
- Environmental vibration tests (1)
- Erhaltung des kulturellen Erbes (1)
- Experimental tests (1)
- F.E.M. Modellierung (1)
- FEM analysis (1)
- FEM modelling (1)
- FEM-Analyse (1)
- Facade composite panels (1)
- Facade panels (1)
- Failure mode (1)
- Feuchteabhängige Festigkeit (1)
- Finite Element Method (1)
- Finite element analysis (1)
- Finite element analysis (FEA) (1)
- Finite-element method (1)
- Formaldehyde (1)
- Geopolymer binders (1)
- Half timbered walls (1)
- Heritage buildings (1)
- Historic structures (1)
- Historical Buildings (1)
- Historical earthen building (1)
- Historische Gebäude (1)
- Hydraulic lime based grout (1)
- Hygrothermal behaviour (1)
- Inelastic torsion (1)
- Initial shear strength test (1)
- Irregular buildings (1)
- Lehmstein (1)
- Lehmstein Mauerwerk (1)
- Lime based grout (1)
- Lime based hydraulic gout (1)
- Lime based hydraulic grout (1)
- Lime mortar (1)
- Macro-modelling approach (1)
- Masonry (1)
- Materials characterization (1)
- Mauerwerk (1)
- Mechanical behavior (1)
- Mechanical properties (1)
- Micro-modelling approach (1)
- Model tuning (1)
- Model updating (1)
- Modified earth plaster (1)
- Natural materials (1)
- Normung (1)
- Partial safety factor (1)
- Partial safety factors (1)
- Production technology (1)
- Prüfverfahren (1)
- Pseudo-dynamic loads (1)
- Pull-out test (1)
- Pull-out testing (1)
- Radon (1)
- Reliability (1)
- Rheology (1)
- Risk analysis (1)
- Risk management (1)
- Rissmuster (1)
- Safety factors (1)
- Sand-lime block (1)
- Sandwich elements (1)
- Scaled models (1)
- Schubversuche (1)
- Seismic resistance (1)
- Seismic response (1)
- Seismic strengthening (1)
- Shaking table tests (1)
- Shear behavior (1)
- Shear bond test (1)
- Slef-cleaning properties (1)
- Static loads (1)
- Static monitoring (1)
- Statische Druck- und Schubbeanspruchung (1)
- Stone masonry (1)
- Strength (1)
- Structural connections (1)
- Subassemblies (1)
- Teilsicherheitsbeiwert (1)
- Test procedures (1)
- Textile reinforced concrete (TRC) (1)
- Triplet test (1)
- UHPC (1)
- Ultra-high performance concrete (1)
- VOC (1)
- Verbundfestigkeit (1)
- Verpressanker (1)
- Versagensart (1)
- Vulnerability (1)
- Wellerlehm (1)
- Ziegelmauerwerk (1)
- Zuverlässigkeit (1)
- Zyklische Belastung (1)
- autoclaved aerated concrete (1)
- autoclaved aerated concrete (AAC) (1)
- cellular lightweight concrete (1)
- cellular lightweight concrete (CLC) (1)
- cyclic shear-compression tests (1)
- earth block masonry (1)
- facade composite panels (1)
- finite element modelling (1)
- historical earthen building (1)
- in-plane loads (1)
- material characterisation (1)
- partial safety factors (1)
- photocatalysis (1)
- pseudo-dynamic tests (1)
- self-cleaning (1)
- self-cleaning properties (1)
- shear behaviour (1)
- static monitoring (1)
- super hydrophobicity (1)
- ultra-high performance concrete (UHPC) (1)
- uniaxial compression test (1)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (5)
- 7.1 Baustoffe (5)
Eingeladener Vortrag
- nein (30)
This study assesses the structural vulnerability of part of a later medieval earthen building at
Ambel (near Zaragoza, Spain), once a preceptory or monastic house belonging to the Military
Orders. An inspection of its morphology and materials coupled with the results of an extensive
campaign of static monitoring reveals marked structural inhomogeneities, the product of more
than a thousand years of construction, failure, and repair from the 10th century to the present
day. Building materials are inappropriately juxtaposed, there are discontinuities between construction
phases and fundamental concerns remain over the long-term stability of the structure.
The current condition of the structure is mainly influenced by structural discontinuities introduced
at the time of construction, the unintended consequences of repair and modification and the
material decay that has affected the base of the rammed earth walls. The overall findings of the
static monitoring show that there is no related damage, variations in crack widths are related to
the building seasonal cycle. While static analysis is an essential prerequisite before a suitable
maintenance program can be fully defined, this study argues that no evaluation of the structural
behavior of any historic building can afford to ignore its archaeological “biography” of modification
and repair.
The repair of earthen structures is not an easy task. Earth as a construction material has comparatively weak mechanical properties. It is also susceptible towards liquid water, were it can lose cohesion very quickly if certain moisture contents are exceeded. Repair concepts of structures built with such materials are therefore challenging. Historical earthen structures often exhibit damages in form of extensive cracking, which may have been caused by static or dynamic loads. Frequently these cracks are insufficiently or inappropriately repaired because of lack of knowledge and / or technology. In particular, the behaviour of crack repair by grouting poses a challenge in earthen materials and demands specific requirements for the grouting mortar, such as low water content, good water retention, low shrinkage. Grouting materials require additional specifications such as compatible strengths and Young’s modulus as well as good adhesion to the earthen substrates. In addition, grouts have to be sufficiently flowable to fill small cracks and voids without segregation or bleeding. Therefore, the rheological behaviour has to be well understood and controlled to gain the desired effects.
The repair of cracks in earthen buildings is traditionally done by stuffing manually mortar into the gap. Naturally, this method is only usable for cracks with large widths. Another disadvantage is that cracks going through thicker walls cannot be completely reached by the tools used for stuffing the mortar into the crack. Lime based grouts for earthen materials were usually used for re-attachment of plasters but less for structural reasons. Due to the nature of earthen materials grouts based on formulated or hydraulic lime (according to the definition in EN 459-1) have to meet considerable demands on a variety of properties, which are related to compatibility, durability and in particular to the ability of being injected. The goal of this study was to create a grout, which can be used to re-establish structural continuity in cracked earthen masonry or other massive earth walls (rammed earth and cob) with the focus on grouting cracks. The grout material was based on hydrated lime (calcium hydroxide) with additions of pozzolana and lime stone filler.
Traditional earthen structures of cultural value are often damaged by static or dynamic loads. This is usually manifested by the appearance of cracks. All too often these cracks are insufficiently or inappropriately repaired if at all because of lack of knowledge and/or technology. In particular, the behavior of crack repair by grouting poses a challenge in earthen materials and demands specific requirements for the grouting mortar, such as low water content, good water retention, low shrinkage, etc. If dynamic loads, e.g. induced by earthquakes, are expected, the grouting material requires additional specifications such as a compatible strength and modulus of elasticity as well as good adhesion to the earthen materials. The study presents results from the development of a grouting material based on hydraulic lime mortar suitable for the repair of cracks in a variety of earthen building techniques. The goal was to develop a material also compatible with earthen structures exposed to dynamic load. The grouting mortar was designed to be adaptable in strength properties and at the same time to have sufficient robustness for the use on the construction site. First results show a satisfactory performance of the grout concerning fresh and hardened mortar properties as well as injectability. The study is part of our work in the framework of the ongoing project NIKER, funded by the European Commission dealing with improving imovable Cultural Heritage assets against the risk of earthquakes.
This study presents diagnostic techniques to assess the structural vulnerability of earthen buildings. Medieval structures at Ambel (near Zaragoza, Spain), once a preceptory or monastic house belonging to the Military Orders, provide a useful case study. After more than a thousand years of construction, failure and repair from the 10th century to the present day, Ambel preceptory today is characterised by marked inhomogeneities: construction materials and structural typologies are juxtaposed, with structural discontinuities at the interfaces between construction phases. This paper argues that, while static analysis is an essential prerequisite before a suitable maintenance program can be defined, no evaluation of the structural behaviour of any historic building can ignore an understanding of the building’s history.
Connections improvement plays a key role in seismic upgrade of historical buildings. Their global response is related to the behaviour of the single structural elements as well as by their mutual connections. Up to now limited data is available on the performance of grouted anchor pins in earthen materials where the critical point is the bond between the grout and the earthen substrate.
In this paper results of the experimental testing performed on earth block masonry are presented. Pull-out tests were carried out to investigate the bond strength and failure modes of stainless steel as well as glass fiber reinforced polymer (GFRP) rods with a lime based hydraulic grout and their compatibility with earth block masonry. GFRP rods were investigated as an alternative bonded-in anchorage material to the commonly used steel. In comparison with steel, they have a reduced weight and a reduced coefficient of thermal expansion. Their lower modulus of elasticity seems to be more compatible with the modulus of elasticity of earthen materials, although they exhibit a brittle fracture with lack of plastic phase.
Connections improvement plays a key role in seismic upgrade of historical buildings. Their global response is related to the behavior of the single structural elements as well as to their mutual connections. Up to now only few data are available about the performance of grouted anchor pins in earthen materials where the critical point is the bond between the grout and the earthen substrate. In this paper, results of the experimental testing performed on earth block masonry, rammed earth and cob are presented. Pull-out tests were carried out to investigate the bond strength and failure modes of stainless steel rods with a lime based hydraulic grout and their compatibility with earthen materials. Rods with nuts were investigated to improve the pull-out capacity of the anchors. They showed higher pull-out capacity than rods without nuts. The performances of rods with nuts in cob were influenced by the rough surface at/of the earthen substrate. It is assumed that the non homogeneous surface caused an interlocking mechanism, which allowed to reach a pull-out capacity of about 54% higher than in earth block masonry.
The goal of the present study is to assess the feasibility to develop a first reliable database of materials parameters for Earth Block Masonry (EBM). The database is crucial when defining the materials safety factors. In the first part an experimental campaign of compressive tests were carried out on two types of earth block and two types of earth mortar. The results showed that the mean variation of the compressive strength was remarkably less than expected. This low variation is related to a production with high quality standards of the materials employed. In the second part a partial safety factor for EBM under uniaxial compression was determined through the reliability method. The results proved the reliability of a common calculation method for EBM based on partial safety factors following the current standards.