The paper presents an experimental program aiming at assessing the mechanical performance of rammed earth walls, namely under compression and shear loading. Axial compression and diagonal compression tests were carried out for this purpose, which allowed determining important mechanical parameters, such as compressive strength, Young's modulus, Poisson's ratio, shear strength and shear modulus. Furthermore, it allowed assessing the level of non-linear behaviour of the respective stress–strain relationships as well as the failure modes. The experimental results were then used in the calibration of numerical models (finite element method) for simulating the non-linear behaviour of rammed earth under shear loading. Both macro- and micro modelling approaches were considered for this purpose. The total strain rotating crack model was used to simulate the behaviour of the rammed earth material, while the Mohr–Coulomb failure criterion was used to simulate the behaviour of interfaces between layers. In general, the numerical models achieved good agreement with the experimental results, but uncertainties related to the definition of the input parameters required to perform a sensitivity analysis. The compressive strength, the Poisson's ratio, the tensile strength and the tensile fracture energy revealed to be the most important parameters in the analyses.
This study analyses the mechanical behaviour under pseudo-dynamic loading of structural elements built in rammed earth and strengthened with polyester fabric strips. This strengthening technique was developed to exploit the strength potential of rammed earth and to solve its lack of tensile strength. For this reason, in-plane cyclic tests were carried out to investigate the shear behaviour of unstrengthened and strengthened walls. The strengthening technique requires low-tech equipment and workmanship, uses readily available, not expensive and industrially standardised materials. The experimental results were analysed in terms of stiffness degradation, energy dissipation capacity and equivalent viscous damping. Although the unstrengthened and strengthened walls confirmed a limited ductile behaviour, the findings confirm that the strengthening contributes to limit the spread of the diagonal cracks and provide an increase of strength in terms of horizontal load and displacement capacity.
This study assesses the structural vulnerability of part of a later medieval earthen building at
Ambel (near Zaragoza, Spain), once a preceptory or monastic house belonging to the Military
Orders. An inspection of its morphology and materials coupled with the results of an extensive
campaign of static monitoring reveals marked structural inhomogeneities, the product of more
than a thousand years of construction, failure, and repair from the 10th century to the present
day. Building materials are inappropriately juxtaposed, there are discontinuities between construction
phases and fundamental concerns remain over the long-term stability of the structure.
The current condition of the structure is mainly influenced by structural discontinuities introduced
at the time of construction, the unintended consequences of repair and modification and the
material decay that has affected the base of the rammed earth walls. The overall findings of the
static monitoring show that there is no related damage, variations in crack widths are related to
the building seasonal cycle. While static analysis is an essential prerequisite before a suitable
maintenance program can be fully defined, this study argues that no evaluation of the structural
behavior of any historic building can afford to ignore its archaeological “biography” of modification
and repair.