Filtern
Dokumenttyp
- Beitrag zu einem Tagungsband (11)
- Buchkapitel (1)
- Vortrag (1)
Sprache
- Englisch (13) (entfernen)
Referierte Publikation
- nein (13) (entfernen)
Schlagworte
- Damage detection (3)
- Damage localization (3)
- Fault detection (3)
- Cable failure (2)
- Cable-stayed bridge (2)
- Load vector (2)
- Model interpolation (2)
- Residual evaluation (2)
- SDDLV (2)
- Statistical evaluation (2)
- Statistical tests (2)
- Structural health monitoring (2)
- Subspace methods (2)
- Temperature rejection (2)
- Changing process noise (1)
- Climate chamber (1)
- Concrete bridge (1)
- Convidence intervals (1)
- Fault isolation (1)
- Laboratory beam structure (1)
- Linear parameter varying systems (1)
- Mechanical systems (1)
- Monitoring techniques (1)
- Numerical computation (1)
- Prestressed concrete bridge (1)
- Schadensdetektion (1)
- Spannbetonbrücke (1)
- Stochastische subspace basierte Identifikation (1)
- Subspace identification (1)
- Subspace-based residual (1)
- Subspace-methods (1)
- Temperature effects (1)
- Uncertainty (1)
- Uncertainty in reference (1)
- Vibration measurement (1)
Organisationseinheit der BAM
- 7 Bauwerkssicherheit (7)
- 7.2 Ingenieurbau (7)
Eingeladener Vortrag
- nein (1)
Structural health monitoring (SHM) of civil structures often is limited due to changing environmental conditions, as those changes affect the structural dynamical properties in a similar way like damages can do. In this article, an approach for damage detection under changing temperatures is presentedand applied to a beam structure. The used stochastic subspace-based algorithm relies on a reference null space estimate, which is confronted to data from the testing state in a residual function. For damage detection the residual is evaluated by means of statistical hypothesis tests. Changes of the system due to temperature effects are handled with a model interpolation approach from linear parameter varying system theory. From vibration data measured in the undamaged state at some few reference temperatures, a model of the dynamic system valid for the current testing temperature is interpolated. The reference null space and the covariance matrix for the hypothesis test is computed from this interpolated model. This approach has been developed recently and was validated in an academic test case on simulations of a mass-spring-damper. In this paper, the approach is validated experimentally on a beam structure under varying temperature conditions in a climate chamber. Compared to other approaches, the interpolation approach leads to significantly less false positive alarms in the reference state when the structure is exposed to different temperatures, while faults can still be detected reliably.
The local asymptotic approach is promising for vibration-based fault diagnosis when associated to a subspace-based residual function and efficient hypothesis testing tools. It has the ability of detecting small changes in some chosen system parameters. In the residual function, the left null space of the observability matrix associated to a reference model is confronted to the Hankel matrix of output covariances estimated from test data. When this left null space is not perfectly known from a model, it should be replaced by an estimate from data to avoid model errors in the residual computation. In this paper, the asymptotic distribution of the resulting data-driven residual is analyzed and its covariance is estimated, which includes also the covariance related to the reference null space estimate. The importance of including the covariance of the reference null space estimate is shown in a numerical study.
Fault detection for linear parameter varying systems under changes in the process noise covariance
(2020)
Detecting changes in the eigenstructure of linear systems is a comprehensively investigated subject. In particular, change detection methods based on hypothesis testing using Gaussian residuals have been developed previously. In such residuals, a reference model is confronted to data from the current system. In this paper, linear output-only systems depending on a varying external physical parameter are considered. These systems are driven by process noise, whose covariance may also vary between measurements. To deal with the varying parameter, an interpolation approach is pursued, where a limited number of reference models -- each estimated from data measured in a reference state -- are interpolated to approximate an adequate reference model for the current parameter. The problem becomes more complex when the different points of interpolation correspond to different noise conditions. Then conflicts may arise between the detection of changes in the eigenstructure due to a fault and the detection of changes due to different noise conditions. For this case, a new change detection approach is developed based on the interpolation of the eigenstructure at the reference points. The resulting approach is capable of change detection when both the external physical parameter and the process noise conditions are varying. This approach is validated on a numerical simulation of a mechanical system.