This publication summarizes the work carried out during an IAEA coordinated research project (CRP) on safe and reliabe management of spent nuclear fuel. This work contributes to the overall goal of demonstrating the performance of spent nuclear fuel and related storage systems components over long durations, and facilitates the transfer of this knowledge to Member States. The technical areas addressed by the CRP participants were related to potential degradation mechanisms in metal casks and concrete overpacks, such as stress corrosion cracking; long term integrity and performance of the fuel cladding; thermo-mechanical behaviour of the metal seals; and long term gamma and neutron shielding capability. The participants also considered past and ongoing demonstration programmes. For each technical topic addressed the main conclusions have been drawn, including information on the development of specific monitoring and inspection techniques as well as future opportunities for closing relevant data gaps. A major achievement is also the establishment of a worldwide network of experts working on current research projects to demonstrate the long term performance of spent fuel in dry storage systems.
Labeling of RGD peptides with near-infrared fluorophores yields optical probes for noninvasive imaging of tumors overexpressing ανβ3 integrins. An important prerequisite for optimum detection sensitivity in vivo is strongly absorbing and highly emissive probes with a known fluorescence lifetime. The RGD-Cy5.5 optical probe was derived by coupling Cy5.5 to a cyclic arginine–glycine–aspartic acid–D-phenylalanine–lysine (RGDfK) peptide via an aminohexanoic acid spacer. Spectroscopic properties of the probe were studied in different matrices in comparison to Cy5.5. For in vivo imaging, human glioblastoma cells were subcutaneously implanted into nude mice, and in vivo fluorescence intensity and lifetime were measured. The fluorescence quantum yield and lifetime of Cy5.5 were found to be barely affected on RGD conjugation but dramatically changed in the presence of proteins. By time domain fluorescence imaging, we demonstrated specific binding of RGD-Cy5.5 to glioblastoma xenografts in nude mice. Discrimination of unspecific fluorescence by lifetime-gated analysis further enhanced the detection sensitivity of RGD-Cy5.5-derived signals. We characterized RGD-Cy5.5 as a strongly emissive and stable probe adequate for selective targeting of ανβ3 integrins. The specificity and thus the overall detection sensitivity in vivo were optimized with lifetime gating, based on the previous determination of the probés fluorescence lifetime under application-relevant conditions.
Dieses Merkblatt beschreibt die Anwendung elektrochemischer Potentialmessungen (häufig auch als Potentialfeldmessung bezeichnet) zur Detektion von Bewehrungsstahlkorrosion an Stahlbetonbauwerken. Mit Hilfe dieses Verfahrens können Bereiche korrodierender Bewehrung zerstörungsfrei lokalisiert werden. In der Regel kommt diese Messmethode bei der Detektion chloridinduzierter Korrosion zum Einsatz. In Abgrenzung hierzu sollte die Abschätzung der Gefahr einer karbonatisierungsinduzierten Korrosion durch Bestimmung der Karbonatisierungstiefe und der Betondeckung erfolgen.
Electrochemical half-cell potential measurements for the detection of reinforcement corrosion
(2014)
This specification describes the application of electrochemical half‐cell potential measurements (frequently also called potential mapping) for the detection of reinforcement corrosion in reinforced concrete structures. Areas of corroding reinforcement steel can be located in a nondestructive manner by means of this procedure. Half‐cell potential measurements are used in order to detect chloride‐induced corrosion. However, it is not recommended in order to assess the risk of carbonation‐induced corrosion. For this purpose the determination of the carbonation depth and the concrete cover appear to be more appropriate.
The content of this specification exclusively refers to the application of mobile, local variable reference electrodes, which are only placed on the concrete surface while measuring. The technique distinguishes itself thereby from the range of corrosion monitoring systems with stationary installed reference electrodes and sensor systems, respectively, whereby it is possible to continuously track measurements within the area of the installed electrodes. However, these methods are not dealt with in this specification.
The through-life management of our constantly ageing infrastructure is a basic requirement in order to ensure their structural safety and serviceability. Each structure experiences deterioration processes with time leading to a decrease of structural safety and serviceability. The design of new structures considers the expected deterioration for a defined period, the design service life. However, a frequent survey of structural safety controlling structural condition should be mandatory and a maintenance plan should be an integral part of the design. In addition, many structures have exceeded their design service life already or are very close to it leading to an increasing demand for condition assessment. On the one hand, assumptions made during design are not valid any more due to change of the loads, e.g., increasing traffic loads in terms of number and weights. On the other hand, design codes evolved over time in such a way that existing structures do not comply with today’s standards. In all these cases, the through-life management is an important tool to maintain the accessibility of existing structures with known reliability.
In line with the new Model Code for Concrete Structures, which includes guidance for both – design of new structures and assessment of existing structures, the Task Group 3.3 focused on the compilation of a state-of-the-art guideline for the through-life management of existing concrete structures, including:
Data acquisition by testing and monitoring techniques;
Condition assessment for the evaluation of existing structures;
Performance prediction using advanced methods;
Decision-making procedures to perform a complete assessment of existing structure.
The overall objective of the through-life management is the assessment of the current condition and the estimation of the remaining service life under consideration of all boundary conditions.
Häufig stellt sich die Frage, ob eine Materialinhomogenität kritisch für die strukturelle Integrität eines Bauteils ist. Dies ist häufig abhängig von der Größe und der Geometrie dieser Materialinhomogenität. Während die korrekte Bestimmung einer Defektgröße zweifelsfrei eine Messaufgabe darstellt, ist die Detektion eines Materialdefekts die Hauptaufgabe eines Prüfsystems. Allerdings sind manche Defekte zu klein, um detektiert zu werden. Es ist jedoch schwierig, etwas zu bemessen, was nur schwer gefunden werden kann, stellen sowohl die Detektion als auch die Fähigkeit den Defekt zu bemaßen, Teile der der Bewertung eines Prüfsystems dar. Die vorliegende Publikation beschäftigt sich zum einen mit der Notwendigkeit, die Auffindwahrscheinlichkeit von Prüfverfahren zu bewerten, und zum anderen mit den Schritten, mit denen das Konzept der Prüfunsicherheitsbewertung national und international vorangetrieben wird. Final werden die Methoden evaluiert, die den Schulterschluss zwischen Prüf- und Messunsicherheitsbestimmung ermöglichen. Ergänzt wird der Artikel mit Beispielen aus der Industrie, welche die aktuelle Relevanz des Themas untermauern.
Die Potentialmessung kann zum Auffinden korrosionsaktiver Bereiche neben Stahlbetonbauwerken auch bei Spannbetonbauwerken angewandt werden, die mit Spannstählen im direkten Verbund hergestellt werden. Bei Vorspannsystemen mit metallischen Hüllrohren im nachträglichen Verbund ist eine Aussage über den Korrosionszustand des Hüllrohrs, nicht aber des Spannstahls möglich. Messungen an Spannbetonbauteilen erfordern grundsätzlich die besonderen Kenntnisse eines Spezialisten.