Several standardized ignition sources are used to determine the safety characteristics of gases, vapours and dusts. Standards indicate the source of ignition but vary in specifying other features such as the burning duration, energy or the volume in which the energy is released. Since heat is not visible under normal conditions, a schlieren technique was used to visualize the entire igniting volume and not just the flames. This article focuses on the igniting volume, compares it among the four standardized ignition sources and displays its relationship to the size of the test vessel. Differences in the ignition behaviour of the ignition sources might lead to the determination of erroneous safety characteristics and with that to the unsafe operation of processes.