Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (99)
- Beitrag zu einem Tagungsband (36)
- Beitrag zu einem Sammelband (18)
- Forschungsbericht (4)
- Vortrag (1)
- Sonstiges (1)
- Posterpräsentation (1)
Sprache
- Englisch (160) (entfernen)
Schlagworte
- POD (12)
- Reliability (9)
- Glass (7)
- LTCC (6)
- X-ray refraction (6)
- XPS (6)
- Dye (5)
- Quantum yield (5)
- Viscosity (5)
- AIE (4)
- Additive manufacturing (4)
- Fluorescence (4)
- Inclusions (4)
- Lifetime (4)
- Odour (4)
- Photophysics (4)
- Sensor (4)
- Water content (4)
- Aggregation (3)
- Energy transfer (3)
- Fatigue (3)
- Geruch (3)
- Glass matrix composites (3)
- Human factors (3)
- Internal friction (3)
- NDT (3)
- Nano (3)
- Nanoparticle (3)
- Nanoparticles (3)
- Odour evaluation (3)
- Particle (3)
- Process analytical technology (3)
- ROC (3)
- Sintering (3)
- Sintering kinetics (3)
- Synthesis (3)
- Thickness (3)
- AgBB-Scheme (2)
- Aggregation induced emission (2)
- Aggregation-induced emission (2)
- Aluminosilicate glasses (2)
- BAMline (2)
- Bauprodukte (2)
- Ceramic matrix composites (2)
- Ceria (2)
- Computed tomography (2)
- Construction product (2)
- Core-shell (2)
- Degradation (2)
- Diffusivity (2)
- Eddy current testing (2)
- Ellipsometry (2)
- Emission test chamber (2)
- Enhancement (2)
- FTIR (2)
- GC-ODP (2)
- GC/MS (2)
- Gas diffusion layer (GDL) (2)
- Glass transition (2)
- Hydroformylation (2)
- ICP-MS (2)
- Imaging (2)
- Infrared spectroscopy (2)
- Interlaboratory study (2)
- Ionic porosity (2)
- Laboratory test (2)
- Laser-induced periodic surface structures (LIPSS) (2)
- MMC (2)
- Microemulsions (2)
- Microscopy (2)
- Modeling (2)
- NDE (2)
- NDT reliability (2)
- NMR spectroscopy (2)
- Nosema ceranae (2)
- Odour standard of comparison (2)
- Osmia bicornis (2)
- Oxidation (2)
- Perceived air quality (2)
- Permeability (2)
- Phase transformation (2)
- Photoluminescence (2)
- Plasticity (2)
- Polarity (2)
- Porosity (2)
- Probability of Detection (2)
- Prozessanalytik (2)
- Radiographic testing (2)
- Radiography (2)
- Raman spectroscopy (2)
- Reaction monitoring (2)
- SAXS (2)
- SVOC (2)
- Selective laser melting (2)
- SiO2 (2)
- Signal enhancement (2)
- Soda-lime-silica (2)
- Solid state emission (2)
- Solubility (2)
- Spectroscopy (2)
- Standardisation (2)
- Stress intensity factor (2)
- Structural Health Monitoring (2)
- Surface analysis (2)
- Switch (2)
- Synchrotron X-ray refraction radiography (2)
- Synchrotron radiation (2)
- Thermal desorption (2)
- Thin films (2)
- UT (2)
- Ultrasonic testing (2)
- VOC (2)
- VVOC (2)
- Vickers indentation (2)
- Viskosität (2)
- Water in glass (2)
- Water speciation (2)
- Wild bees (2)
- X-ray computed tomography (2)
- X-ray scattering (2)
- X-ray tomography (2)
- Zirconia (2)
- Zuverlässigkeit (2)
- 2D (1)
- 4-Eye Principle (1)
- AbBB-Schema (1)
- Absorption correction (1)
- Acceptability (1)
- Acetyl-DON (1)
- Acoustics (1)
- Acrylic and silicone sealant (1)
- Additive Manufacturing (1)
- Additive manufacturing (AM) (1)
- AgBB (1)
- AgBB scheme (1)
- Ageing (1)
- Aggregates (1)
- Al2O3-inclusions (1)
- Alkali aluminosilicate glasses (1)
- Alkali and alkaline earth silicate and borate glass (1)
- Alumina dissolution (1)
- Aluminium (1)
- Aluminoborosilicate glass (1)
- Analyse (1)
- Analyser based imaging (1)
- Antigraffiti system (1)
- Antioxidant (1)
- Assessment procedure (1)
- Attenuation (1)
- Austenitic Tube Welds (1)
- Automated analysis (1)
- Automation Bias (1)
- Automotive engineering (1)
- Axles (1)
- BIM (1)
- Batch reactions (1)
- Bayesian Approach (1)
- Bayesian approach (1)
- Bayesian statistics (1)
- Bee diseases (1)
- Bee health (1)
- Bewertung (1)
- Biologie (1)
- Bioregenerative ceramics (1)
- Bispidines (1)
- Blauer Engel (1)
- Blue Angel (1)
- Bond energy (1)
- Borate (1)
- Borate glasses (1)
- Boratgläser (1)
- Borosilicate glass (1)
- Bragg magnification (1)
- Bragg-Magnification (1)
- Brain (1)
- Brick (1)
- Brittle fracture (1)
- Building product (1)
- Building products (1)
- Bulk metallic glasses (1)
- C-dot (1)
- C-scan (1)
- CIEE (1)
- CLSM (1)
- Calculated intrinsic fracture toughness (1)
- Calibration (1)
- Caloric properties (1)
- Carbon dot (1)
- Ceramic matrix composite (1)
- Certification (1)
- Chalcopyrite-type (1)
- Chamber test (1)
- Chamber tests (1)
- Characterization (1)
- Charge transfer (1)
- Charring (1)
- Chelates (1)
- Chemical analysis (1)
- Chemical mapping (1)
- Chicken manure ash (1)
- Cleaning (1)
- Click chemistry (1)
- Coherent imaging (1)
- Combustion and gasification (1)
- Comparison (1)
- Composite (1)
- Composite materials (1)
- Composites (1)
- Composition (1)
- Compression device (1)
- Computed Tomography (1)
- Construction products (1)
- Coverings (1)
- Crack growth (1)
- Crack growth in air (1)
- Creep (1)
- Crystal lattice (1)
- Crystallization (1)
- Cu(In,Ga)Se2 (1)
- Cultural heritage (1)
- Cyclic load (1)
- DCB (1)
- DCB geometry (1)
- DON-3-glucoside (1)
- DTAB (1)
- Damage (1)
- Damage evolution (1)
- Data analysis (1)
- Decision support (1)
- Defects (1)
- Dental composite materials (1)
- Deoxynivalenol (DON) (1)
- Depth profiling (1)
- Diagnostics (1)
- Diastolic dysfunction (1)
- Digital Models (1)
- Digitale Detektoren (1)
- Directive (1)
- Doppelrotation (1)
- Drop Tests (1)
- Drop testing (1)
- Durability (1)
- Dynamic behavior (1)
- Dynamic loads (1)
- EB-weld (1)
- EB-welding (1)
- Eddy current inspection (1)
- Effective Viscosity (1)
- Elastic constants (1)
- Elastodynamic Finite Inegration Technique (1)
- Electron spectroscopy (1)
- Electron transfer (1)
- Elemental distributions (1)
- Emission (1)
- Emission tests (1)
- Emissionen (1)
- Emissions (1)
- Emissionsmessung (1)
- Emissionsmessungen (1)
- Emulsions (1)
- Emuslions (1)
- Environmental sign (1)
- Epoxy (1)
- Essential Parameters (1)
- European Standards (1)
- Evaluation (1)
- Eye Tracking (1)
- FAIRification (1)
- FEA (1)
- Failure Modes and Effects Analysis (FMEA) (1)
- Femtosecond laser (1)
- Femtosecond laser ablation (1)
- Film Digitalization (1)
- Fire detection (1)
- Flame retardancy (1)
- Floor coverings (1)
- Fluorescent probe (1)
- Fluorescent probes (1)
- Forest (1)
- Fracture surface energy (1)
- Fragility (1)
- GIXRR (1)
- Gas diffusion layers (1)
- Gas sensor (1)
- Gas sorption (1)
- Gas-diffusion layers (1)
- Geometrical tortuosity (1)
- Geosynthetic (1)
- Germination (1)
- Geruchstest (1)
- Glas Matrix Composites (1)
- Glasmatrixkomposite (1)
- Glass Matrix Composites (1)
- Glass ceramics (1)
- Glass forming melts (1)
- Glass liner (1)
- Glass manufacturing (1)
- Glass-ceramics definition (1)
- HDPE (1)
- Health assessment (1)
- Health care (1)
- Heart failure (1)
- Hedonic (1)
- Hierarchically porous (1)
- High pressure (1)
- High pressure experiments (1)
- Historische Baustoffe (1)
- Holotomography (1)
- Homogenization schemes (1)
- Human Factor (1)
- Human Factors (1)
- Hydrocarbon (1)
- Hydrogen diffusivity (1)
- Hydrogen gas (1)
- Hydrogen permeation (1)
- Hydrogen sensor (1)
- Hydrogen storage tank (1)
- Hydrous glass (1)
- IDMS (1)
- INCONEL 718 (1)
- IR (1)
- ISO 23173 (1)
- Imaging agents (1)
- In-Service Inspection (ISI) (1)
- In-situ characterization of GDLs (1)
- In-situ synchrotron X-ray computed tomography (1)
- In-situ synchrotron X-ray radiography (1)
- Indentation fracture toughness (1)
- Indolone merocyanines (1)
- Industrial and Manufacturing Engineering (1)
- Interfacial charge (1)
- Interlaboratory comparison (1)
- Inverse method (1)
- Ionic liquid (1)
- Iron (1)
- Kammermessungen (1)
- Kernresonanz, magnetisch (1)
- Kinetic Modelling (1)
- Label (1)
- Labelling systems (1)
- Labelsysteme (1)
- Lacquers (1)
- Lanthanides (1)
- Laser (1)
- Laser Ablation (1)
- Laser Ablation ICP-MS (1)
- Laser ablation (1)
- Ligand (1)
- Limestone (1)
- Lipids (1)
- Liver X receptor (1)
- Lösung (1)
- MEIS (1)
- MOUSE (1)
- MS (1)
- Magnetic resonance imaging (1)
- Magnetite (1)
- Malting (1)
- Masked mycotoxins (1)
- Materialschutz (1)
- Mechanical strength (1)
- Merocyanine (1)
- Messmethoden (1)
- Metal foams (1)
- Metal ions (1)
- Metal matrix composite (MMC) (1)
- Metal matrix composites (1)
- Metal-organic framework (1)
- Metoligotoma (1)
- Micelle (1)
- Micro X-ray fluorescence spectroscopy (1)
- Micro analysis (1)
- Micro texture (1)
- Microcracking (1)
- Microhardness (1)
- Microporous layer (1)
- Microporous materials (1)
- Microstructure (1)
- Microtomography (1)
- Mixing (1)
- Modelling (1)
- Modular Model (1)
- Modulares Modell (1)
- Monitoring (1)
- Monument (1)
- Multi-parameter signal response (1)
- Multiparameter POD (1)
- Multiparameter-POD (1)
- Mycotoxins (1)
- Mössbauer spectroscopy (1)
- N,O ligands (1)
- NDE reliability (1)
- NDT-methods (1)
- NMR (1)
- NRA (1)
- Nanaoparticle (1)
- Nano-object (1)
- Nanoindentation (1)
- Nanomaterial categorisation (1)
- Nanomaterial definition (1)
- Nanomaterial legislation (1)
- Nanomaterial regulation (1)
- Nanopowder (1)
- Neutron reflectometry (1)
- Non-Destructive Inspection (NDI) (1)
- Non-Destructive Testing (1)
- Non-destructive evaluation (1)
- Nonlinear behavior (1)
- Normung (1)
- Nuclear Power Plants (1)
- Nuclear Waste Storage (1)
- Nuclear medical application (1)
- Nuclear receptor (1)
- Nuclear waste (1)
- Nucleation tendency (1)
- Nutrient (1)
- Nydrogen melting (1)
- OMS (1)
- Odor (1)
- Odour labelling (1)
- Online NMR Spectroscopy (1)
- Online NMR spectroscopy (1)
- Online Raman Spectroscopy (1)
- Online-spectroscopy (1)
- Open space technology (1)
- Organismus (1)
- PEM fuel cell (1)
- PEMFC (1)
- POD-curves (1)
- Package (1)
- Paints (1)
- Pathogen spillover (1)
- Pathogen transmission (1)
- Perceived air-quality (1)
- Perceived intensity (1)
- Perceived odour intensity (1)
- Performance Demonstration (1)
- Phosphate extractability and availability (1)
- Phylogeny (1)
- Plant availability (1)
- Plasma oxidation (1)
- Pollutant (1)
- Polymer (1)
- Polymer electrolyte membrane fuel cell (1)
- Polyneoptera (1)
- Polypropylene (1)
- Pore size analysis (1)
- Porous materials (1)
- Powders (1)
- Probability of detection curves (1)
- Process Analytical Technology (1)
- Product labelling (1)
- Profiling (1)
- Prozess-Spektroskopie (1)
- Prüfung (1)
- Pyrolysis (1)
- Quantitative NMR spectroscopy (1)
- RBS (1)
- Radioactive labelling (1)
- Radiographic Testing (1)
- Radiographic inspection (1)
- Radiolabeling (1)
- Railway (1)
- Rauchkammer (1)
- Reaction Monitoring (1)
- Real defect testing (1)
- Reasonability (1)
- Reduction factor (1)
- Refraction (1)
- Reinforcement (1)
- Relaxation (1)
- Reliability of NDE (1)
- Reliability of NDE Systems (1)
- Resolution neutron-radiography (1)
- Rheology (1)
- Rietveld analysis (1)
- Rigid Inclusion (1)
- Robocasting (1)
- Röntgen (1)
- SCS6 (1)
- SIMS (1)
- SPECT (1)
- Safety (1)
- Sample preparation (1)
- Sandstone (1)
- Schweißnähte (1)
- Scintillator (1)
- Secondary cemetitious materials (1)
- Secondary ion mass spectrometry (1)
- Semi volatile organic compounds (1)
- Sensor system (1)
- Sensory tests (1)
- Shear thinning (1)
- Silica (1)
- Silicate glass (1)
- Silicates (1)
- Silicatgläser (1)
- Silicoborate glasses (1)
- Silicon dioxide (1)
- Silver metallization paste (1)
- Sintering Kinetics (1)
- Sintern (1)
- Size (1)
- Slow crack growth (1)
- Small-angle X-ray scattering (1)
- Smoke gases (1)
- Soda lime silicate glass (1)
- Soda-lime silicate glass (1)
- Soda-lime-silica glass (1)
- Solar cells (1)
- Solid-state reaction (1)
- Solid/liquid interfaces (1)
- Solitary bees (1)
- Solvothermal synthesis (1)
- Spent nuclear fuel (1)
- Stable crack growth (1)
- Standard (1)
- Standardization (1)
- Standing waves (1)
- Stiffness (1)
- Streaming current (1)
- Stress intensity (1)
- Stress-corrosion (1)
- Stress-strain curves (1)
- Structural health monitoring (1)
- Structural relaxation (1)
- Subcritical crack growth (1)
- Sugar cane bagasse (1)
- Surface chemistry (1)
- Surface chemisttry (1)
- Surface functionalization (1)
- Surface group analysis (1)
- Survey (1)
- Survival rates (1)
- Synchrotron (1)
- Synchrotron Radiation (1)
- Synchrotron Refraction CT (1)
- Synchrotron X-ray imaging (1)
- Synchrotron X-ray refraction (1)
- Synchrotron X-ray tomography (1)
- Synchrotron instrumentation (1)
- Synchrotron radiography (1)
- Synchrotron tomography (1)
- Synchrotron-CT (1)
- Syntheseis (1)
- System Identification (1)
- Sythesis (1)
- TEM (1)
- TIMS (1)
- TRL-UT (1)
- Tensile tests (1)
- Test method (1)
- Test procedure (1)
- Testing using sensors (1)
- Thermal analysis (1)
- Thermische Analyse (1)
- Thermochemical treatment (1)
- Thermogravimetric analysis (TGA) (1)
- Ti-MMC (1)
- Ti6242 (1)
- Time Pressure (1)
- Titania nanoparticles (1)
- Titanium Metal Matrix Composites (Ti-MMC) (1)
- TomoCAR (1)
- Tomographie (1)
- Tortuosity (1)
- Transport properties (1)
- Triazine (1)
- Tribology (1)
- Ultra high performance concrete (1)
- Ultrasonic (1)
- Ultrasonic Guided Waves (1)
- Ultrasonic inspection (1)
- Ultrasonic relaxation (1)
- VOC emission (1)
- VOC-emission (1)
- VOCs (1)
- Very volatile organic compounds (1)
- Visual inspection (1)
- Visual testing (1)
- Visualization (1)
- Volatile emission (1)
- Volatile organic compounds (1)
- Volumetric properties (1)
- Wassergehalt (1)
- Wasserhaltige Gläser (1)
- Water (1)
- Water distribution (1)
- Water filtration (1)
- Water transport (1)
- Water transport path (1)
- Water-bearing glasses (1)
- Weathering (1)
- Winkel, magisch (1)
- Wood-based product (1)
- X-Ray Refraction (1)
- X-ray (1)
- X-ray Computed Tomography (1)
- X-ray diffraction (XRD) (1)
- X-ray phase contrast (1)
- X-ray photoelectron spectroscopy (1)
- X-ray radiography (1)
- X-ray refraction radiography (1)
- X-ray spectrometry (1)
- X-ray topography (1)
- XRD (1)
- XSW (1)
- Zerstörungsfreie Prüfung (1)
- Zuverlässigkeit von ZfP-Systemen (1)
- dye (1)
- hydrogen storage (1)
- multi-collector (1)
- reference material (1)
- sensory evaluation of building materials and rooms (1)
- uncertainty budget (1)
Organisationseinheit der BAM
- 5 Werkstofftechnik (16)
- 5.6 Glas (16)
- 8 Zerstörungsfreie Prüfung (13)
- 6 Materialchemie (11)
- 8.5 Röntgenbildgebung (11)
- 1 Analytische Chemie; Referenzmaterialien (10)
- 6.1 Oberflächen- und Dünnschichtanalyse (7)
- 1.2 Biophotonik (6)
- 4 Material und Umwelt (4)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (3)
Eingeladener Vortrag
- nein (1)
27Al nuclear magnetic resonance spectra of polycrystalline aluminium borate 9Al2O3 · 2B2O3 have been measured in double rotation at 11.7 and 7.0 T and high-speed magic-angle spinning at 7.0, 9.4, 11.7, 14.1 and 17.6 T. Spinning sidebands from the satellite transitions were observed at 7.0 and 14.1 T. Each of the four structural aluminium sites [Al(IV), Al(V)(1), Al(V)(2) and Al(VI)] are observed, characterised and assigned in the spectra. The obtained parameter set gives a fully consistent interpretation in agreement with the crystal structure of the compound.
A comparison of different isotope dilution mass spectrometric (IDMS) procedures using inductively coupled plasma mass spectrometry (ICPMS) and thermal ionization mass spectrometry (TIMS) was carried out to examine the degree of equivalence between the used procedures in terms of requirements for reference material certification. The comparison was based on the measurement results and their uncertainties. The sample used in this study is a pure zinc metal to be certified by the Bureau Communie de Référence (BCR) for amount contents of different trace elements. This study focuses on cadmium and thallium. The TIMS values contributed to the certified values. To guarantee identical conditions as far as possible for the procedures under investigation, the samples were split into subsamples after spiking and digestion took place. Thus, every IDMS procedure started with an identical set of samples. In total, four different IDMS procedures and one external calibration procedure using internal standardization as an example of routine analysis were applied. The IDMS procedures divide in a group with and a group without trace/matrix separation. Multicollector TIMS (TI-MC-MS) and multicollector ICPMS (ICP-MC-MS) were used in combination with trace/matrix separation, whereas quadrupole ICPMS (ICP-QMS) and ICP-MC-MS were also applied to nonseparated samples. All IDMS results agree well within their combined uncertainties, while some results from the external calibration procedure do not. IDMS results obtained by ICPMS without separation are comparable to those obtained by TI-MC-MS with separation regarding precision and accuracy. The smallest uncertainties were achieved using ICP-MC-MS in combination with trace/matrix separation.
Long-term behaviour of geosynthetic drains - excavations on landfills after up to 12 years service
(2002)
Theory of nucleation in viscoelastic media: application to phase formation in glassforming melts
(2003)
Glassforming melts behave, in the vicinity of the temperature of vitrification Tg, as viscoelastic bodies. A general theory of nucleation in a viscoelastic body developed elsewhere is applicable to the description of phase formation processes in such systems. The present contribution is directed to the demonstration of the relevance of this proposed general theory to describing phase transformation processes in glassforming melts. The application of the theory is shown to explain a number of experimental results on crystallization of glassforming melts, which have not found a satisfactory interpretation so far.
For the first time Metal Matrix Composites (MMC) have been investigated by 3D Computed Tomography combined with enhanced interface contrast due to X-ray refraction. X-ray refraction is a relatively new approach for the characterization of advanced materials. The related techniques of Refraction Topography and Refraction Computed Tomography have been developed and applied at our laboratory during the last decade to meet the actual demand for improved nondestructive characterization of high performance composites, ceramics and other low density materials and components. X-ray refraction occurs, when X-rays crosses interfaces of spherical or cylindrical shape (e.g. pores or fibres) in the same way as visible light is refracted by lenses. These X-ray optical effects can be observed at small scattering angles of few minutes of arc as the refractive index n of X-rays is nearly unity (n = 1 10-6). Due to the short X-ray wavelength of about 0.1 nm the technique determines the amount of inner surfaces and interfaces of nanometer dimensions. The technique is expected to solve many problems in understanding the meaning of micro and sub micro structures in materials science. With the results of the CT investigation, some questions could be clarified for a better understanding of fatigue failure mechanisms under cyclic loading conditions. The specimens for the test programme have been provided by MTU Aero Engines. They consist of a titanium matrix (Ti6242) reinforced by SiC fibres (SCS6). The investigations have been performed at the materials research station of BAM (BAMline) at the Synchrotron Facility BESSY in Berlin, Germany.
Results are reported from a pilot study under the Consultative Committee for Amount of Substance (CCQM) to compare measurements of and resolve any relevant measurement issues in, the amount of thermal SiO2 oxide on (100) and (111) orientation Si wafer substrates in the thickness range 1.5 - 8 nm. As a result of the invitation to participate in this activity, 45 sets of measurements have been made in different laboratories using 10 analytical methods: medium-energy ion scattering spectrometry (MEIS), nuclear reaction analysis (NRA), RBS, elastic backscattering spectrometry (EBS), XPS, SIMS, ellipsometry, grazing-incidence x-ray reflectrometry (GIXRR), neutron reflectometry and transmission electron microscopy (TEM). The measurements are made on separate sets of 10 carefully prepared samples, all of which have been characterised by a combination of ellipsometry and XPS using carefully established reference conditions and reference parameters.
The results have been assessed against the National Physical Laboratory (NPL) data and all show excellent linearity. The remaining data sets correlate with the NPL data with average root-mean-square scatters of 0.15 nm, half being better than 0.1 nm and a few at or better than 0.05 nm. Each set of data allows a relative scaling constant and a zero thickness offset to be determined. Each method has an inherent zero thickness offset between 0 nm and 1 nm and it is these offsets, measured here for the first time, that have caused many problems in the past. There are three basic classes of offset: water and carbonadeous contamination equivalent to ~1 nm as seen by ellipsometry; adsorbed oxygen mainly from water at an equivalent thickness of 0.5 nm as seen by MEIS, NRA, RBS and possibly GIXRR; and no offset as seen by XPS using the Si 2p peaks. Each technique has a different uncertainty for the scaling constant and consistent results have been achieved. X-Ray photoelectron spectroscopy has large uncertainties for the scaling constant but a high precision and, critically, if used correctly, has zero offset. Thus, a combination of XPS and the other methods allows the XPS scaling constant to be determined with low uncertainty, traceable via the other methods. XPS laboratories returning results early were invited to test a new reference procedure. All showed very significant improvements. The reference attenuation lengths thus need scaling by 0.986 ± 0.009 (at an expansion factor of 2) deduced from the data for the other methods. Several other methods have small offsets and, to the extent that these can be shown to be constant or measurable, then these methods will also show low uncertainty. Recommendations are provided for parameters for XPS, MEIS, RBS and NRA to improve their accuracy.
Erstmals wurden MMCs mit Hilfe der Interface-Kontrast verstärkenden Röntgen-Refraktions-Technik in Kombination mit der 3D-CT-Technik untersucht. Die Methode der Röntgen-Refraktions-Topography sowie der Röntgen-Refraktions-Tomography wurden in den letzten Jahren speziell für die zerstörungsfreie Charakterisierung von Leichtbau-Hochleistungs-Werkstoffen wie Verbund-Werkstoffen und Keramiken entwickelt. Die Technik basiert auf der Refraktion von Röntgenlicht an Grenzflächen zwischen Bereichen unterschiedlicher Elektronendichte wie z.B. Faser- und Matrix-Werkstoff. Auf Grund der kurzen Röntgen-Wellenlänge hat der Brechungsindex einen Wert dicht bei eins, sodass der Streuwinkel nur wenige Bogenminuten beträgt. Der Vorteil der kurzen Wellenlänge besteht jedoch darin, dass Poren und Risse detektiert werden können, deren Größe im Nanometerbereich liegen. Damit kann die Refraktions-Technik zum besseren Verständnis von Mikro- und Submikro-Strukturen in der Materialwissenschaft eingesetzt werden. Mit der hier vorgestellten Refraktions-CT wurden Ermüdungsmechanismen an MMCs, bestehend aus SiC-Faser verstärktem Titan (Ti6242) untersucht. Die Messungen wurden am Röntgen-Messplatz der BAM (BAMline) am Synchrotron-Speicherring-BESSY in Berlin Adlershof durchgeführt.
The sintering of Low Temperature Co-fired Ceramics prepared from alumoborosilicate
glass- and Al2O3 powders of similar small particle size was studied by dilatometry, heating microscopy,
microstructure analysis, glass- and effective viscosity measurements. The steric effect of
Al3O3 inclusions was studied using a gnon-reactiveh model composite. With increasing Al3O3 volume
fraction (Φ ≤ 0.45), sintering decelerates and its final stage shifts to higher temperature. The
attainable shrinkage is reduced as Al2O3 particle clusters bearing residual pores become more frequent.
The kinetics of sintering could be described formally superposing the weighed contributions
of differentially sized and randomly composed glass-crystal particle clusters and assuming a sintering
rate controlled by the effective matrix viscosity, which increases with Φ and with progressive
wetting of Al2O3 particles during densification. The "reactive" model composite shows significant
dissolution of Al2O3 into the glass, which has two opposed effects on sintering: reducing Φ and increasing
glass viscosity. For the present case (Φ = 0.25), the latter effect dominates and sintering is
retarded by Al2O3 dissolution. Crystallization of wollastonite starts after full densification. Dissolution
of Al2O3 was found to promote the subsequent growth of anorthite.
In this study 50 construction products were tested in emission test chambers according to the requirements of the AgBB-scheme: 7 acrylic and 6 silicone sealants, 6 paste-like synthetic resin plasters, 13 wood based products, 4 adhesives, 5 lacquers, 6 wall paints and 3 further construction products. VOC and odour emissions were tested on the 1st, 3rd, 10th, and 28th day. In addition to the VOC-measurements, a test procedure was developed to evaluate odour emission of construction products.This test is planned to be implemented into the AgBB-Scheme. A direct evaluation by a sensory panel in the emission test chamber was not possible. So the odour samples were collected in 300- litre tedlar bags which were evaluated later. Odour intensity of the samples was compared with different acetone concentrations. Within this study an interlaboratory comparison was conducted using the newly developed odour test method. Additionally, VVOC emissions, detection of carcinogenic compounds, repeatability of emission test chamber tests, and other issues are presented. This project has shown that construction products can be evaluated in accordance with the AgBB scheme. A sensory evaluation is intended to be introduced in the AgBB scheme. A method for this evaluation is described in this study. The test procedure should be enhanced and validated for practical utilisation.
We studied sintering of LTCC-type glass matrix composites (GMCs) consisting of small glass and alumina particles of equal size. Primarily, crystals act as rigid inclusions, decelerating the densification rate. In later stages, they also dissolve, partially increasing the viscosity. Release of alumina finally induces crystallization of alumosilicates, which enables post-firing stability. To study both effects, two model GMCs were prepared: an α-Al2O3 + barium alumoborosilicate glass (BABS)GMC, which shows neither significant dissolution nor crystallization, and an α-Al2O3 + calcium alumoborosilicate glass (CABS)GMC, which dissolves readily and promotes crystallization. The kinetics of shrinkage for both GMC were modeled by utilizing Frenkel theory for the early stage and MackenzieShuttleworth theory for the late stage, assuming that sintering is superimposed by the weighted contributions of triparticle glasscrystal clusters, their random occurrence (ideal mixing), and a shrinkage rate controlled by the GMC effective viscosity. In agreement with modeling, the experimental results showed that the shrinkage rate of BABSGMC decreases progressively for crystal volume fractions Φ > 0.15. The attainable shrinkage is reduced by up to 8% for Φ = 0.45. For the CABSGMC with Φ = 0.25, a reduction of Φ to 0.20 was evident due to partial α-Al2O3 dissolution. This effect was found able to increase the sintering temperature by ~5060 K.
The viscosity of silica glasses with different water contents was measured by penetration of sapphire microspheres in the range from 1012-1014·7 Pas at ambient pressure. Commercial silica glasses were used together with hydrous silica glasses, which were prepared by melting glass powder plus water in an internally heated pressure vessel at 2-3 kbar and 1350-1450°C. The temperature dependence of the viscosity of silica glasses with total water contents Cw of 5·4×10-4, 7·0×10-4, 1·00×10-2, and 1·55×10-2(Cw in mass fractions) can be described by Arrhenius equations. From the results, the linear dependence of the T12 isokom (K) with the logarithm of the water content was determined as T12=192-409 logCw. The analysis of the compositional dependence of the T12 isokom in the H2O-Na2O-SiO2 system reveals a temperature depression of up to 200 K for mixed water- and sodium-bearing glasses compared to H2O-SiO2 and Na2O-SiO2 glasses with same molar silica content. From these findings we conclude that protons may contribute significantly to the mixed alkali effect in glasses.
To properly understand and assess the long-term behaviour of geosynthetic materials it is necessary to investigate the various types of possible degradation mechanims. This includes both chemical and mechanical behaviour, and sometimes even their interactions with one another. Clearly, chemical degradation of geosynthetics depends on the polymer type. For example, polyolefins are vulnerable to oxidation; polyesters are susceptible to hydrolysis; and plasticizers can leach from polyvinyl chloride. This paper describes the concept of these three types of degradation, but focuses on the oxidation of polyolefins since the majority of the geosynthetics is made from this type of polymer. The methods used to predict the lifetime of antioxidants and service life of the geosynthetic material will be illustrated. Furthermore, the influence of temperature, pressure, and ultraviolet light on the service life are also demonstrated. Finally, the current specifications targeting the longevity of different geosynthetics are presented.
Regarding mechanical degradation, the paper mainly focuses upon the creep deformation of geogrids and stress crack resistance (SCR) of polyethylene geomembranes and geopipe. The method to assess stress crack resistance is described, and the microscopic mechanisms that lead to such failure are explained. For creep evaluation, different acceleration tests are presented and their applicability with respect to the different types of polymers is illustrated. In addition, the long-term shear behaviour of geocomposites and geosynthetic clay liners is presented.
The high-resolution synchrotron-based imaging stations at the BAMline (BESSY) and TopoTomo (ANKA)
(2008)
The BAMline at the BESSY light source in Berlin and the TopoTomo beamline at the ANKA synchrotron facility in Karlsruhe (both Germany) operate in the hard X-ray regime (above 6 keV) with similiar photon flux density. For typical imaging applications, a double multilayer monochromator or a filtered white beam is used. In order to optimise the field of view and the resolution of the available indirect pixel detectors, different optical systems have been installed, adapted, respectively, to a large field of view (macroscope) and to high spatial resolution (microscope). They can be combined with different camera systems, ranging from 16-bit dynamic range slow-scan CCDs to fast CMOS cameras. The spatial resolution can be brought substantially beyond the micrometer limit by using a Bragg magnifier. The moderate flux of both beamlines compared to other 3rd generation light sources is compensated by a dedicated scintillator concept. For selected applications, X-ray beam collimation has proven to be a reliable approach to increase the available photon flux density. Absorption contrast, phase contrast, holotomography and refraction-enhanced imaging are used depending on the application. Additionally, at the TopoTomo beamline digital white beam synchrotron topography is performed, using the digital X-ray pixel detectors installed.
Lithium disilicate, leucite and apatite glass-ceramics have become state-of-the-art framework materials in the fabrication of all-ceramic dental restorative materials. The goal of this study was to examine the crack propagation behaviour of these three known glass-ceramic materials after they have been subjected to Vickers indentation and to characterize their crack opening profiles (δmeas vs. (a-r)). For this purpose, various methods of optical examination were employed. Optical microscopy investigations were performed to examine the crack phenomena at a macroscopic level, while high-resolution techniques, such as scanning electron microscopy (SEM) and atomic force microscopy (AFM), were employed to investigate the crack phenomena at a microscopic level. The crack patterns of the three glass-ceramics vary from fairly straightforward to more complex, depending on the amount of residual glass matrix present in the material. The high-strength lithium disilicate crystals feature a high degree of crosslinking, thereby preventing crack propagation. In this material, the crack propagates only through the residual glass phase, which constitutes 30%40% by volume. Having a high glass content of more than 65% by volume, the leucite and apatite glass-ceramics show far more complex crack patterns. Cracks in the leucite glass-ceramic propagate through both the glass and crystal phase. The apatite glass-ceramic shows a similar crack behaviour as an inorganicorganic composite material containing nanoscale fillers, which are pulled out in the surroundings of the crack tip. The observed crack behaviour and the calculated View the MathML source values of the three types of glass-ceramics were compared to the Kkic values determined according to the SEVNB method.
Service life of geosynthetics made of polyolefin materials is mainly limited by oxidative degradation. Durability of polyolefin products depend on formulation, morphology resulting from manufacturing, design and particularly on the antioxidants used. Although the fundamental oxidative reactions are known, the complex effect of geosynthetic characteristics and external influences mean that durability assessments require practical tests.
The assessment of oxidative durability involves exposure to accelerating conditions as well as the material characterisation with respect to the state of stabilisation and/or degradation (e.g. by tensile testing and/or oxidation induction time).
The autoclave test developed by BAM for durability assessments of polyolefin geosynthetics is based on the simultaneous application of moderately elevated temperatures (up to 80 degrees Celsius) and elevated oxygen pressures (up to 5.0 MPa) in combination with a surrounding aqueous medium. Thus this test method provides several advantages in comparison to conventional oven testing, especially with respect to test duration, impact of surrounding environment and the potential to differentiate and rank oxidative resistance between products of very different dimensions (surface/volume) and stabilisation.
In view of the increasing demand for durability assessments of geosynthetic products with lifetimes significantly exceeding 25 years, the contribution is focused on practical aspects concerning implementation and optimisation of test procedures, conditions and evaluation of results. Furthermore, advanced approaches based on multiple exposure conditions will also be included and corresponding calculations of expected service life in typical applications will be evaluated with respect to significance and repeatability. Thereby involved standards and recommendations - such as EN ISO 13438, Part C or EAG-EDT - are considered.
Whenever geosynthetics are used to reinforce or stabilise infrastructural elements such as road- and railways, bridge abutments, run- and taxiways on airports or to protect coastlines of canals and other steep slopes they may be exposed to cyclic loads. Therefore, a reduction factor for dynamic effects on the geosynthetic tensile strength has been included into the calculation of the Long Term Design Strength (LTDS). An approach to assess the behaviour of geosynthetics is to adopt Woehler- or Smith graphs and Haigh-diagrams for polymers. This is because an endurance limit for polymers, which defines an infinite life under a defined cyclic load, has not been seen so far. A huge amount of mechanical testing is needed to predict the behaviour of geosynthetics against this particular background.
To reduce these efforts while getting an indication of the cyclic effect on geosynthetics, a combined method of mechanical and chemical analysis has been developed. The pure tensile strength tests to determine the residual strength after cyclic stress has been amended by IR-spectroscopy and Differential Scanning Calorimetry (DSC). In this context the chain change model of PET has been proven as valid for cyclic loads as well, which helps to define the endurance limit of materials made out of PET. For polyolefins such as PP and PE, a limit for the maximum alternating load has been identified at the point of the stress strain graph where the actual and the numerical stress of a material diverge from each other. Cyclic tensile strength tests have been carried out in a hydraulic test frame. The test parameters have been set to simulate the service life of a railway bed trafficked by high speed trains (ICE).
The effect of hydration on the kinetic fragility of soda-lime-silica glasses was investigated by viscometry in the glass transition range. Water-bearing glasses were prepared from industrial float glass (FG) and a ternary model glass (NCS = 16Na2O 10CaO 74SiO2 in mol%) by bubbling steam through the melt at 1480 °C and up to 7 bar. Additionally, a sodium borosilicate glass (NBS = 16Na2O 10B2O3 74SiO2 in mol%) was hydrated under equal conditions. As detected by infrared spectroscopy water dissolves in the glasses exclusively as OH-groups. The hydration resulted in a total water content CW up to ~ 0.2 wt% for FG, NCS and NBS glasses. Kinetic fragility, expressed by the steepness index m, was determined from the temperature dependence of η at the glass transition. Viscosity data from previous studies on hydrous float glasses (CW > 1 wt%) were surveyed together with literature data on the (H2O)Na2OCaOSiO2, (H2O)Na2OSiO2 and (H2O)SiO2 systems to expand the range of water concentration and bulk composition. We could demonstrate that m decreases for all glasses although water is dissolved as OH and should depolymerize the network. An empirical equation of the general type m = a - b logCW where a, b are fitting parameters, enables m to be predicted, for each glass series as function of the water content CW. The enlarged data base shows that the parameter B of the Arrhenius viscosity-temperature relation decreases much stronger than the isokom temperature at the glass transition.
Measuring perceived air quality and intensity by a Sensor System, the European Project SysPAQ
(2008)
The paper will give an overview of new methodology for evaluating the
reliability of NDE systems accurately, reliably and efficiently in accordance with the
specific requirements of industrial application. After a review of the substantive
issues from the previous workshops, the go forward guidance from these
interactions is considered.
At the beginning of the reliability analysis, the actual safety demands have to
be defined in order to fit the investigation to the level of risk when the component
would fail. Next, all the essential influencing parameters need to be documented and
transferred to an appropriate design of experiments (DOE) to determine the
reliability in terms of a qualitative assessment for lower risk or in terms of a
quantitative probability of detection (POD) or ROC (Receiver Operating
Characteristics) curves for higher safety demands. A new paradigm is offered to
consider the POD or reliability of the system as a function of the configuration of
input variables and use it for optimisation rather than for a final judgement. An
advantage for the end user is also to sample all single PODs to an integral 'Volume
POD' of a part.
Among the influencing parameters, the human factor is the most important one.
A systematic psychological approach shall help to find out where the bottlenecks are
but most importantly to provide best possible working conditions for the human
inspectors.
Fabrication of modern microelectronic components requires miscellaneous solder materials for joining. In order to guarantee the quality of the manufacturing process and the reliability of the resulting solder joint it is necessary to know the material properties of the joining parts and of the solder materials. In particular Youngs modulus, yield stress, and the hardness are of great interest. Moreover, a complete stress-strain curve is important for a detailed material characterization and simulation of a component, e.g., by Finite Elements (FE). The miniaturization of modern electronic products with small solder joints allows only fabrication of very small-sized specimens. Because of this miniature tests are used for measuring the mechanical properties of the solders in the experimental investigations of this paper. More specifically two miniature tests are presented and discussed, a mini-uniaxial-tension-test and a nanoindenter experiment. In the tensile test the axial loading is prescribed, the corresponding extension of the specimen length is recorded, both of which determines the stress-strain- curve directly. The stress-strain curves are then mathematically analyzed by assuming a non-linear relationship between stress and strain of the Ramberg-Osgood type and fitting the corresponding parameters to the experimental data by means of an optimization routine. For a detailed analysis of very local mechanical properties nanoindentation is used, resulting primarily in load vs. indentation-depth data. According to the procedure of Pharr and Oliver this data can be used to obtain hardness and Youngs modulus but not a complete stress-strain curve, at least not directly. In order to obtain such a stress-strain-curve, the nanoindentation experiment is combined with FE and the coefficients involved in the corresponding constitutive equation for stress and strain are obtained by means of the inverse method. Finally in this paper, the stress-strain curves from nanoindentation and tensile tests are compared for two materials, namely aluminum and steel and differences are explained in terms of the locality of the measured properties.