Multi-sensory monitoring and ultrasound for quality assurance at underground sealing structures
(2023)
Within the safety concepts of underground disposal sites of nuclear waste, engineered barriers play an important role. As these sealing structures have high demands concerning integrity, we aim at advancing the available construction materials, monitoring, and inspection techniques within the project SealWasteSafe. A specifically developed alkali-activated material is compared to classical salt concrete. A comprehensive multi-sensory monitoring scheme is used at 150-340 l specimens to monitor setting and hardening of both materials. All sensors are demonstrated to resist the highly alkaline environments. Besides cabled and wireless temperature and humidity of the materials, strain variations using fibre optic sensors and acoustic emissions are recorded over periods of at least 28 days, partly for more than eight months. After hardening of the specimens, further nondestructive evaluations using ultrasonic echo and thermographic measurements are conducted.
Preliminary results proof the suitability of the tested sensors and clearly highlight differences between the tested materials. Particularly, the newly developed alkali-activated material shows lower acoustic emission activity indicating less cracking activity. Additionally, unique ultrasonic methods will enable better images of potential internal objects and cracks at in-situ sealing structures. A largescale ultrasonic system is optimised to reliably detect objects at a depth exceeding 9 m while still obtaining a good resolution. Modelling studies show the potential of further increasing the distance between individual transducer arrays. Additionally, a new ultrasonic borehole probe using phased arrays allowing for beam focussing is constructed and tested. Laboratory measurements at a halfcylindrical concrete specimen coincide well with the previous modelling. In total, the presented safe materials, detailed monitoring approaches and ultrasonic quality assurance methods will help to obtain safe sealing structures within salt as a host rock. The concepts can partly be transferred to sealing structures in alternative host rocks and will also be valuable for non-nuclear waste repositories.
This contribution introduces an investigation of a large-scale prestressed concrete bridge model (“BLEIB” structure at the BAM-TTS open air test site) by means of on-site cooperative measurements. This bridge has an external post-tensioning system and has been instrumented with the ultrasonic transducers, temperature sensors and optical fibers for Distributed Acoustic Sensing (DAS). Our experiment was designed to test the suitability of the novel 6C sensors developed within the framework of the GIOTTO project – the IMU50. The IMU50 sensor enables vibration measurements in translation along three axes and rotation around three axes. The geophone sensors were considered for complementary measurements of vertical velocity response. In the experiment, several perturbations were achieved by controlling the external influence factors such as loading and prestressing changes. The aim of the integrated measurement strategy was to fully observe the results of the condition change and to verify the effectiveness of multiple sensors for bridge monitoring.
Die B1 Brücke am Altstädter Bahnhof in Brandenburg an der Havel wurde im Dezember 2019 aufgrund von während einer turnusmäßigen Inspektion entdeckten Rissen und Hohlstellen entlang der vorgespannten Längsträger gesperrt und im Mai 2021 abgebrochen. In der Zwischenzeit wurde die Brücke detailliert überwacht. Vor dem Abriss wurden zudem umfangreiche Untersuchungen zur Bestandsaufnahme und Schadensanalyse sowie Tests moderner Sensorik vorgenommen. Dabei konnte sowohl die richtige, zuvor nicht sicher bekannte Anzahl von Spanngliedern in den Querträgern sicher ermittelt werden als auch durch moderne Varianten der Schwingungsmessungen und der faseroptischen Sensorik zusätzliche Kenntnisse püber das Bauwerksverhalten ermittelt werden . In dem Beitrag werden die Verfahren mit ihren Möglichkeiten und Grenzen vorgestellt, die Ergebnissee an der Brücke in Brandenburg erläutert und zukünftige Einsatzmöglichkeiten diskutiert.
Before the final disposal of radioactive wastes, various processes can be implemented to optimise the waste form. This can include different chemical and physical treatments, such as thermal treatment for waste reduction, waste conditioning for homogenisation and waste immobilisation for stabilisation prior to packaging and interim storage. Ensuring the durability and safety of the waste matrices and packages through performance and condition assessment is important for waste owners, waste management organisations, regulators and wider stakeholder communities. Technical achievements and lessons learned from the THERAMIN and PREDIS projects focused on low- and intermediate-level waste handling is shared here. The recently completed project on Thermal Treatment for Radioactive Waste Minimization and Hazard Reduction (THERAMIN) made advances in demonstrating the feasibility of different thermal treatment techniques to reduce volume and immobilise different streams of radioactive waste (LILW) prior to disposal. The Pre-Disposal Management of Radioactive Waste (PREDIS) project addresses innovations in the treatment of metallic materials, liquid organic waste and solid organic waste, which can result from nuclear power plant operation, decommissioning and other industrial processes. The project also addresses digitalisation solutions for improved safety and efficiency in handling and assessing cemented-waste packages in extended interim surface storage.
Die B1 Brücke am Altstädter Bahnhof in Brandenburg an der Havel wurde im Dezember 2019 aufgrund von während einer turnusmäßigen Inspektion entdeckten Rissen und Hohlstellen entlang der vorgespannten Längsträger gesperrt und im Mai 2021 abgebrochen. In der Zwischenzeit wurde die Brücke detailliert überwacht. Vor dem Abriss wurden zudem umfangreiche Untersuchungen zur Bestandsaufnahme und Schadensanalyse sowie Tests moderner Sensorik vorgenommen. Dabei konnte sowohl die richtige, zuvor nicht sicher bekannte Anzahl von Spanngliedern in den Querträgern sicher ermittelt werden als auch durch moderne Varianten der Schwingungsmessungen und der faseroptischen Sensorik zusätzliche Kenntnisse püber das Bauwerksverhalten ermittelt werden . In dem Beitrag werden die Verfahren mit ihren Möglichkeiten und Grenzen vorgestellt, die Ergebnissee an der Brücke in Brandenburg erläutert und zukünftige Einsatzmöglichkeiten diskutiert.
The project "SealWasteSafe" of the Bundesanstalt für Materialforschung und -prüfung (BAM, Berlin) deals with sealing structures applied for underground disposal of nuclear waste from two perspectives: (1) material improvement for application in sealing constructions and (2) feasibility study regarding multi-sensor approaches to ensure quality assurance and long-term monitoring.
One specimen of 150 l made of alkali-activated material, which was found innovative and suitable for sealing constructions based on preliminary laboratory studies, and, for comparison purpose, another one made of salt concrete, are manufactured with an integrated multi-sensory setup for quality assurance and long-term-monitoring. The specimens were left in their cast form and additionally thermally insulated to simulate the situation in the repository. The multi-sensory concept comprises RFID technology embedded in the specimens suppling material temperature and moisture measurements, integrated fibre optic sensing allowing strain measurement and acoustic emission testing for monitoring possible crack formation. Overall, the suitability and the functionality of the sensors embedded into and attached to strongly alkaline (pH > 13 for the AAM) and salt corrosive (NaCl) environment was proven for the first 672 h.
First temperature measurement based on RFID succeeded after 626 h for the alkali-activated material and after 192 h for the conventional salt concrete. Strain measurement based on distributed fibre optic sensing turned out the alkali-activated material with > 1 mm m-1 undergoing approximately twice the compression strain as the salt concrete with strains < 0.5 mm m-1. In contrast, the acoustic emission first and single hits representing crack formation in numbers, was found for alkali-activated material half of that detected at the salt concrete.
This contribution introduces an investigation of a large-scale prestressed concrete bridge model (“BLEIB” structure at the BAM-TTS open air test site) by means of on-site cooperative measurements. This bridge has an external post-tensioning system and has been instrumented with the ultrasonic transducers, temperature sensors and optical fibers for Distributed Acoustic Sensing (DAS). Our experiment was designed to test the suitability of the novel 6C sensors developed within the framework of the GIOTTO project – the IMU50. The IMU50 sensor enables vibration measurements in translation along three axes and rotation around three axes. The geophone sensors were considered for complementary measurements of vertical velocity response. In the experiment, several perturbations were achieved by controlling the external influence factors such as loading and prestressing changes. The aim of the integrated measurement strategy was to fully observe the results of the condition change and to verify the effectiveness of multiple sensors for bridge monitoring.
A new type of ultrasonic borehole probe is currently under development for the quality assurance of sealing structures in radioactive waste repositories using existing research boreholes. The goal is to examine the sealing structures made of salt concrete for possible cracks, delamination, and embedded objects. Earlier prototype probes use 12 or 16 individual dry point contact (DPC) horizontal shear wave transducers grouped into a transmitter and a receiver array, each made up of six or eight individual transducers. They are operated with a commercially available portable ultrasonic flaw detector used in the civil engineering industry. To increase the generated sound pressure of the borehole probe, the number of transducers in the novel probe is increased to 32. In addition, timed excitation of each probe is used to direct a focused sound beam to a specific angle and distance based on calculated time delays. Hence, the sensitive test volume is limited, and the signal-to-noise ratio of the received signals is improved. This paper presents the validation of the newly developed phased array borehole probe by beam computation in CIVA software and experimental investigations on a semi-cylindrical test specimen to investigate the directional characteristics. In combination with geophysical reconstruction techniques, an optimised radiation pattern of the probe is expected to improve the signal quality and thus increase the reliability of the imaging results.
This is of great importance for the construction of safe sealing structures needed for the disposal of radioactive or toxic waste.
Concrete structures are invaluable assets to a society and managing them efficiently and effectively can be supported by information gathered through structural health monitoring (SHM). In this paper, a combined approach based on passive, i.e., acoustic emission (AE), and active, i.e., ultrasonic stress wave (USW) monitoring techniques for application to concrete structures is proposed and evaluated. While AE and USW are based on the same underlying physics, i.e., wave motion in solids, they differ fundamentally with respect to the nature of the source. For the former, external stimuli such as mechanical loads or temperature cause the rapid release of energy from initially unknown locations. As a result, AE events are unique and cannot be repeated. For the latter, a known source at a known location is employed at a specified time. This approach is thus controlled and repeatable. It is
argued that a combination of these two techniques has the potential to provide a more comprehensive picture of ongoing fracture processes, damage progression, as well as slowly occurring aging and degradation mechanisms.
This combined approach does thus promise new opportunities to support condition assessment of concrete structures. After providing an overview and comparison of the two techniques, results, and observations from a full-scale laboratory experiment and an in-service bridge monitoring study are discussed to demonstrate the promise of the proposed combined monitoring approach. Finally, suggestions for further work are presented.
This presentation summarizes the opbjectives and the progress of the EURATOM project PREDIS (pre-disposal management of radioactive waste) and its workpackage 7 in particular. Focus is on the development of wireless sensors for monitoring radioactive waste packages, measuring radiation, temperature, pressure and humidity.