Laboratory Study:
Combining Signal Features of Ground-Penetrating Radar to Classify Moisture Damage in Layered Building Floors
https://doi.org/10.3390/app11198820
On-Site Study:
TBA
Doctoral Thesis:
Non-destructive classification of moisture deterioration in layered building floors using ground penetrating radar
https://doi.org/10.14279/depositonce-19306
Measurement Parameters
The GPR measurements were carried out with the SIR 20 from GSSI and a 2 GHz antenna pair (bandwidth 1 GHz to 3 GHz) in common-offset configuration. Each B-Scan consists of N A-Scans, each including 512 samples of a 11 ns time window. Survey lines were recorded with 250 A-Scans/ meter, which equals a 4 mm spacing between each A-Scan No Gains were applied.
Folder Description:
Lab_dry, Lab_insulDamage, Lab_screedDamage
- each contain 168 Measurements (B-Scans) in .csv on 84 dry floors, floors with insulation damage and screed damage.
- each floor setup was measured twice on two orthogonal survey lines, indicated by _Line1_ and _Line2_ in the file name.
- the file names encode the building floor setup e.g. CT50XP100 describes a 50 mm cement screed with 100 mm extruded polystyrene below
- the material codes are
CT: cement screed, CA: anhydrite screed, EP: expanded polystyrene, XP: extruded polystyrene, GW: glass wool, PS: perlites
further information can be found in the publication https://doi.org/10.3390/app11198820
OnSite_
- 5 folders containing B-Scans on 5 different practical moisture damages
- the building floor setup is encoded according to the lab with an additional measurement point numbering at the start and a damage case annotation at the end of the file name with _dry, _insulationDamage and_screedDamage
File Description:
B-Scans, Measurement files - no header
- dimension: 512 x N data point with N beeing the number of A-Scans including 512 samples of a 11 ns time window.
- survey lines were recorded with 250 A-Scans/ meter, which equals a 4 mm spacing between each A-Scan
Moisture References
- Moist_Reference of On-Site Locations include the columns MeasPoint: Measurement point, wt%Screed: moisture content of screed layer in mass percent; wt%Insul: moisture content of insulation layer in mass percent. References were obtained by drilling cores with 68 mm diameter in the center of each survey line.
- Moist_Reference_Screed of Lab data include the columns Screed: Screed material and thickness in mm, wt%Screed moisture content of screed layer in mass percent
- Moist Reference_Insul of Lab data include the columns Insulation: Insulation material and thickness in mm, water addition in l: water added to the insulation layer in liters, V%Insulation: water added to the insulation layer in volume percent, RH%: resulting relative humidy in the insulation layer during measurement. These References are only avaible for Lab measurements on insulation damages.