Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (68)
- Vortrag (5)
- Posterpräsentation (3)
- Beitrag zu einem Tagungsband (2)
- Corrigendum (1)
Schlagworte
- Quantum yield (37)
- Fluorescence (27)
- Photoluminescence (22)
- Lanthanide (20)
- NIR (18)
- Upconversion (17)
- Lifetime (16)
- Nano (16)
- Photophysics (16)
- Nanoparticle (13)
Organisationseinheit der BAM
Paper des Monats
- ja (2)
Eingeladener Vortrag
- nein (5)
The commercial availability of stand-alone setups for the determination of absolute photoluminescence quantum yields (φf) in conjunction with the increasing use of integrating sphere accessories for spectrofluorometers is expected to have a considerable influence not only on the characterization of chromophore systems for use in optical and opto-electronic devices, but also on the determination of this key parameter for (bio)analytically relevant dyes and functional luminophores. Despite the huge potential of systems measuring absolute φf values and the renewed interest in dependable data, evaluated protocols for even the most elementary case, the determination of the fluorescence quantum yield of transparent dilute solutions of small organic dyes with integrating sphere methods, are still missing. This encouraged us to evaluate the performance and sources of uncertainty of a simple commercial integrating sphere setup with dilute solutions of two of the best characterized fluorescence quantum yield standards, quinine sulfate dihydrate and rhodamine 101, strongly differing in spectral overlap between absorption and emission. Special attention is dedicated to illustrate common pitfalls of this approach, thereby deriving simple procedures to minimize measurement uncertainties and improve the comparability of data for the broad community of users of fluorescence techniques.
To improve the reliability of fluorescence data in the life and material sciences and to enable accreditation of fluorescence techniques, standardization concepts are required that guarantee and improve the comparability of fluorescence measurements. At the core of such concepts are simple and evaluated fluorescence standards for the consideration of instrument-specific spectral and intensity distortions of measured signals and for instrument performance validation (IPV). Similarly in need are fluorescence intensity standards for the quantification from measured intensities and for signal referencing, thereby accounting for excitation light-induced intensity fluctuations. These standards should be preferably certified, especially for use in regulated areas like medical diagnostics. This encouraged us to develop liquid and solid standards for different fluorescence parameters and techniques for use under routine measurement conditions in different formates. Special emphasis was dedicated to the determination and control of the spectral responsivity of detection systems, wavelength accuracy, homogeneity of illumination, and intensity referencing for e.g. spectrofluorometers, fluorescence sensors and confocal laser scanning fluorescence microscopes. Here, we will present design concepts and examples for mono- and multifunctional fluorescence standards that provide traceability to radiometric units and present a first step towards a toolbox of standards.
We present the synthesis and characterization of multifunctional fluorophore-labeled poly(organosiloxane) nanoparticles with core-shell architecture, where the fluorescent dye is incorporated into the core. Grafting of heterobifunctional poly(ethylene oxide) (PEO) onto the particle surface leads to water-soluble biocompatible nanoparticles. Two different strategies have been used for the synthesis: The encapsulation of dye-labeled monomers during the polycondensation with additional PEO coating and subsequent dye labeling by covalent attachment of the fluorescent dye rhodamine B to the (chloromethylphenyl)siloxane groups in the core after polymerization and grafting of PEO onto the surface. Comparison of the fluorescence quantum yields of the nanoparticles before and after PEO coating show a decrease in quantum yield after PEO coating.
Polystyrene nanoparticles (PS-NPs) were doped with an oxygen-sensitive near-infrared (NIR)-emissive palladium meso-tetraphenylporphyrin and an inert reference dye which are both excitable at 635 nm. The nanosensors were characterized with special emphasis on fundamental parameters such as absolute photoluminescence quantum yield and fluorescence lifetime. The PS-NPs were employed for ratiometric dual-wavelength and lifetime-based photoluminescent oxygen sensing. They were efficiently taken up by cultured murine alveolar macrophages, yielding a characteristic and reversible change in ratiometric response with decreasing oxygen concentration. This correlated with the cellular hypoxic status verified by analysis of hypoxia inducible factor-1α (HIF-1α) accumulation. In addition, the surface of PS-NPs was functionalized with polyethylene glycol (PEG) and the monoclonal antibody herceptin, and their binding to HER2/neu-overexpressing tumor cells was confirmed in vitro. First experiments with tumor-bearing mouse revealed a distinctive ratiometric response within the tumor upon hypoxic condition induced by animal sacrifice. These results demonstrate the potential of these referenced NIR nanosensors for in vitro and in vivo imaging that present a new generation of optical probes for oncology.
A setup for fluorescence upconversion spectroscopy (FLUPS) is described which has 80 fs temporal response (fwhm) for emission in the spectral range 425–750 nm. Broadband phase matching is achieved with tilted gate pulses at 1340 nm. Background from harmonics of the gate pulse is removed and sensitivity increased compared to previous designs. Photometric calibration of the upconversion process is performed with a set of fluorescent dyes. For Coumarin 153 in methanol the peak position, bandwidth, and asymmetry depending on delay time are reported.
The photoluminescence quantum yield (Φf) that presents a direct measure for the efficiency of the conversion of absorbed photons into emitted photons is one of the spectroscopic key parameters of functional fluorophores. It determines the suitability of such materials for applications in, for example, (bio)analysis, biosensing, and fluorescence imaging as well as as active components in optical devices. The reborn interest in accurate Φf measurements in conjunction with the controversial reliability of reported Φf values of many common organic dyes encouraged us to compare two relative and one absolute fluorometric method for the determination of the fluorescence quantum yields of quinine sulfate dihydrate, coumarin 153, fluorescein, rhodamine 6G, and rhodamine 101. The relative methods include the use of a chain of Φf transfer standards consisting of several 'standard dye' versus 'reference dye' pairs linked to a golden Φf standard that covers the ultraviolet and visible spectral region, and the use of different excitation wavelengths for standard and sample, respectively. Based upon these measurements and the calibration of the instruments employed, complete uncertainty budgets for the resulting Φf values are derived for each method, thereby providing evaluated standard operation procedures for Φf measurements and, simultaneously, a set of assessed Φf standards.
Unter dem Motto „Innovation und Qualitätssicherung in der (Bio)Analytik“ werden in der Arbeitsgruppe Fluoreszenzspektroskopie der BAM, Bundesanstalt für Materialforschung und -prüfung, funktionelle Chromophor-Systeme, einfache Signalverstärkungs- und Multiplexingstrategien sowie innovative Validierungs- und rückführbare Standardisierungskonzepte für verschiedene fluorometrische Messgrößen und Methoden entwickelt. Im Mittelpunkt stehen dabei molekulare Fluorophore, Nanokristalle mit größenabhängigen optischen Eigenschaften (sogenannte Quantenpunkte, QDs) und fluoreszierende Partikel variabler Größe sowie Sonden und Sensormoleküle für neutrale und ionische Analyte und für die Charakterisierung von funktionellen Gruppen. Dabei erfolgen auch methodische Entwicklungen für die Fluoreszenzspektroskopie, die Fluoreszenzmikroskopie, die Milcrofluorometrie, die Sensorik und die Mikroarraytechnologie. Ziele sind u. a. das Design und die Untersuchung von multiplexfähigen selektiven und sensitiven Sonden für die Biomarkeranalytik, die Entwicklung von Methoden zur Charakterisierung der signalrelevanten Eigenschaften dieser Chromophor-Systeme und zur Charakterisierung von funktionellen Gruppen an Oberflächen und ihre Validierung sowie die Entwicklung und Bereitstellung von formatadaptierbaren, flexibel ersetzbaren
Standards für die fluoreszenzbasierte Multiparameteranalytik.
The widespread use and acceptance of fluorescence techniques especially in regulated areas like medical diagnostics is closely linked to standardization concepts that guarantee and improve the comparability and reliability of fluorescence measurements. At the core of such concepts are dependable fluorescence standards that are preferably certified. The ever rising interest in fluorescence measurements in the near-infrared (NIR) spectral region renders the availability of spectral and intensity standards for this wavelength region increasingly important. This encouraged us to develop approaches to solid NIR standards based upon dye-doped polymers and assess their applicationrelevant properties in comparison to metal ion-doped glasses. The overall goal is here to provide inexpensive, easily fabricated, and robust internal and external calibration tools for a broad variety of fluorescence instruments ranging e.g. from spectrofluorometers over fluorescence microscopes to miniaturized fluorescence sensors.
Encapsulation of hydrophobic dyes in polystyrene micro- and nanoparticles via swelling procedures
(2011)
Aiming at the derivation of a generalized
procedure for the straightforward preparation of particles
fluorescing in the visible and near-infrared (NIR) spectral
region, different swelling procedures for the loading of the
hydrophobic polarity-probe Nile Red into nano- and
micrometer sized polystyrene particles were studied and
compared with respect to the optical properties of the
resulting particles. The effect of the amount of incorporated
dye on the spectroscopic properties of the particles was
investigated for differently sized beads with different
surface chemistries, i.e., non-functionalized, aminomodified
and PEG-grafted surfaces. Moreover, photostability
and leaking studies were performed. The main criterion
for the optimization of the dye loading procedures was a
high and thermally and photochemically stable fluorescence
output of the particles for the future application of these
systems as fluorescent labels.
The amount of grafted poly(acrylic acid) on poly(methyl methacrylate) micro- and nanoparticles was quantified by conductometry, 13C solid-state NMR, fluorophore labeling, a supramolecular assay based on high-affinity binding of cucurbit[7]uril, and two colorimetric assays based on toluidine blue and nickel complexation by pyrocatechol violet. The methods were thoroughly validated and compared with respect to reproducibility, sensitivity, and ease of use. The results demonstrate that only a small but constant fraction of the surface functional groups is accessible to covalent surface derivatization independently of the total number of surface functional groups, and different contributing factors are discussed that determine the number of probe molecules which can be bound to the polymer surface. The fluorophore labeling approach was modified to exclude artifacts due to fluorescence quenching, but absolute quantum yield measurements still indicate a major uncertainty in routine fluorescence-based surface group quantifications, which is directly relevant for biochemical assays and medical diagnostics. Comparison with results from protein labeling with streptavidin suggests a porous network of poly(acrylic acid) chains on the particle surface, which allows diffusion of small molecules (cutoff between 1.6 and 6.5 nm) into the network.
There is an increasing interest in chromophores absorbing and emitting in the near-infrared (NIR) spectral region, e.g., for applications as fluorescent reporters for optical imaging techniques and hence, in reliable methods for the characterization of their signal-relevant properties like the fluorescence quantum yield (Φf) and brightness. The lack of well established Φf standards for the NIR region in conjunction with the need for accurate Φf measurements in transparent and scattering media encouraged us to built up an integrating sphere setup for spectrally resolved measurements of absolute fluorescence traceable to radiometric scales. Here, we present the design of this setup and its characterization and validation including an uncertainty budget for the determination of absolute Φf in the visible and NIR. To provide the basis for better measurements of Φf in the spectral window from ca. 600 to 1000 nm used, e.g., for optical imaging, the absolute Φf of a set of NIR chromophores covering this spectral region are measured and compared to relative values obtained using rhodamine 101 as Φf standard. Additionally, the absolute Φf values of some red dyes that are among the most commonly used labels in the life sciences are presented as well as the absolute quantum yield of an optical probe for tumor imaging.
Here, we present a detailed characterisation of rhodamine B-containing magnetoliposomes (FLU-ML), emphasising the dependence of their fluorescence properties on the presence of iron oxide cores, and the molar fraction of the fluorophore. The magnetoliposome types used exist as colloidally stable, negatively charged clusters with an average hydrodynamic diameter of 95 nm. The molar rhodamine B fractions were 0.67 % and 1.97 %. Rhodamine B normalised fluorescence, quantum yields and fluorescence lifetimes were substantially reduced by inner filter effects as the magnetoliposome concentration is increased, by increasing molar rhodamine B fraction, and by quenching originating from the iron oxide cores. MR relaxometry at 3 T revealed extremely high r2 relaxivities (440 to 554 s-1mM-1) and moderately high r1 values (2.06 to 3.59 s-1mM-1). Upon incubating human prostate carcinoma (PC-3) cells with FLU-ML, a dose-dependent particle internalisation was found by MR relaxometry. In addition, the internalised FLU-ML were clearly visible by fluorescence microscopy. At the FLU-ML concentrations used (up to 3 × 103 M Fe) cell viability was not substantially impaired. These results provide valuable insights on the fluorescence properties of bimodal magnetoliposomes and open promising perspectives for the use of these materials as a platform technology for advanced functional and molecular MR and optical imaging applications.
Synthesis and characterisation of highly fluorescent core-shell nanoparticles based on Alexa dyes
(2012)
Current and future developments in the
emerging field of nanobiotechnology are closely
linked to the rational design of novel fluorescent
nanomaterials, e.g. for biosensing and imaging applications.
Here, the synthesis of bright near infrared
(NIR)-emissive nanoparticles based on the grafting
of silica nanoparticles (SNPs) with 3-aminopropyl
triethoxysilane (APTES) followed by covalent attachment
of Alexa dyes and their subsequent shielding by an
additional silica shell are presented. These nanoparticles
were investigated by dynamic light scattering (DLS),
transmission electron microscopy (TEM) and fluorescence
spectroscopy. TEM studies revealed the monodispersity
of the initially prepared and fluorophorelabelled
silica particles and the subsequent formation of
raspberry-like structures after addition of a silica
precursor.Measurements of absolute fluorescence quantum
yields of these scattering particle suspensions with
an integrating sphere setup demonstrated the influence
of dye labelling density-dependent fluorophore aggregation
on the signaling behaviour of such nanoparticles.
The rational design of nano- and micrometer-sized particles with tailor-made optical properties for biological, diagnostic, and photonic applications requires tools to characterize the signal-relevant properties of these typically scattering bead suspensions. This includes methods for the preferably nondestructive quantification of the number of fluorophores per particle and the measurement of absolute fluorescence quantum yields and absorption coefficients of suspensions of fluorescent beads for material performance optimization and comparison. Here, as a first proof-of-concept, we present the first time determination of the number of dye molecules per bead using nondestructive quantitative (19F) NMR spectroscopy and 1000 nm-sized carboxylated polystyrene particles loaded with varying concentrations of the laser dye coumarin 153 containing a CF3 group. Additionally, the signal-relevant optical properties of these dye-loaded particles were determined in aqueous suspension in comparison to the free dye in solvents of different polarity with a custom-built integrating sphere setup that enables spectrally resolved measurements of emission, transmission, and reflectance as well absolute fluorescence quantum yields. These measurements present an important step toward absolute brightness values and quantitative fluorescence analysis with particle systems that can be exploited, for example, for optical imaging techniques and different fluorescence assays as well as for the metrological traceability of fluorescence methods.
In order to develop simple and versatile procedures for the preparation of red emissive particles, various one-step swelling procedures for the loading of fluorophores into nanometer- and micrometer-sized polystyrene particles were systematically assessed. Parameters studied for model dyes from common dye classes include the composition of the swelling medium, dye charge and polarity, dye concentration, and particle surface chemistry. The dye loading procedures were compared based upon the efficiency of dye incorporation, fluorescence intensity, and colloidal stability of the resulting particles as well as the absence of dye leaking as determined by absorption and fluorescence spectroscopy, flow cytometry, and measurements of zeta potentials. In addition, for the first time, the influence of the amount of incorporated dye on the absolute fluorescence quantum yield and brightness of the fluorescent particles was investigated for selected chromophores in differently sized particles using a custom-made calibrated integrating sphere setup. Our results demonstrate the general suitability of these one-step loading procedures for efficient particle staining with neutral, zwitterionic, and charged fluorophores like oxazines, coumarines, squaraines, xanthenes, and cyanines emitting in the visible and near infrared. Dye polarity was identified as a suitable tool to estimate the loading efficiency of fluorophores into these polymer particles.
To establish the methodical basis for the development and certification of fluorescence quantum yield standards, we determined the fluorescence quantum yield Φf of rhodamine 6G (R6G) with two absolute methods with complementary measurement principles, here optical spectroscopy using an integrating sphere setup and pulsed laser photoacoustic spectroscopy (PAS). For the assessment of aggregation- and reabsorption-induced distortions of measured fluorescence quantum yields and procedures for the reliable consideration of such effects, this systematic comparison was performed in ethanol and in water employing different concentrations of R6G. In addition, the relative and absolute fluorescence quantum yields of these solutions were obtained with a calibrated spectrofluorometer and a commercialized integrating sphere setup. Based upon this systematic comparison, experimental advantages and systematic sources of variation were identified for both methods.
Current optical probes including engineered nanoparticles (NPs) are constructed from near infrared (NIR)-emissive organic dyes with narrow absorption and emission bands and small Stokes shifts prone to aggregation-induced self-quenching. Here, we present the new asymmetric cyanine Itrybe with broad, almost environment-insensitive absorption and emission bands in the diagnostic window, offering a unique flexibility of the choice of excitation and detection wavelengths compared to common NIR dyes. This strongly emissive dye was spectroscopically studied in different solvents and encapsulated into differently sized (15, 25, 100 nm) amino-modified polystyrene NPs (PSNPs) via a one-step staining procedure. As proof-of-concept for its potential for pre-/clinical imaging applications, Itrybe-loaded NPs were surface-functionalized with polyethylene glycol (PEG) and the tumor-targeting antibody Herceptin and their binding specificity to the tumor-specific biomarker HER2 was systematically assessed. Itrybe-loaded NPs display strong fluorescence signals in vitro and in vivo and Herceptin-conjugated NPs bind specifically to HER2 as demonstrated in immunoassays as well as on tumor cells and sections from mouse tumor xenografts in vitro. This demonstrates that our design strategy exploiting broad band-absorbing and -emitting dyes yields versatile and bright NIR probes with a high potential for e.g. the sensitive detection and characterization of tumor development and progression.
Calcium, strontium, and barium copper silicates are demonstrated to possess valuable photophysical properties which make them particularly attractive for application in optical chemosensors. Several examples of sensing materials based on these phosphors are provided. Particularly, broad excitation and near-infrared emission makes them ideal candidates for the preparation of ratiometric sensors based on absorption-based indicators. Due to their excellent chemical and photochemical stability and high brightness, these phosphors can serve as reference for fluorescent indicators to enable ratiometric intensity or dually lifetime referenced measurements. Finally, the moderate temperature dependence of the luminescence decay time enables intrinsic temperature compensation of the sensing materials at ambient temperatures. The improved sensitivity at temperatures above 100 °C makes these new materials promising candidates for high-temperature thermographic phosphors.
Luminescence techniques are among the most widely used detection methods in the life and material sciences. At the core of these methods is an ever-increasing variety of fluorescent reporters (i.e., simple dyes, fluorescent labels, probes, sensors and switches) from different fluorophore classes ranging from small organic dyes and metal ion complexes, quantum dots and upconversion nanocrystals to differently sized fluorophore-doped or fluorophore-labeled polymeric particles. A key parameter for fluorophore comparison is the fluorescence quantum yield (Φf), which is the direct measure for the efficiency of the conversion of absorbed light into emitted light. In this protocol, we describe procedures for relative and absolute determinations of Φf values of fluorophores in transparent solution using optical methods, and we address typical sources of uncertainty and fluorophore class-specific challenges. For relative determinations of Φf, the sample is analyzed using a conventional fluorescence spectrometer. For absolute determinations of Φf, a calibrated stand-alone integrating sphere setup is used. To reduce standard-related uncertainties for relative measurements, we introduce a series of eight candidate quantum yield standards for the wavelength region of ~350950 nm, which we have assessed with commercial and custom-designed instrumentation. With these protocols and standards, uncertainties of 5–10% can be achieved within 2 h.
Critical review of the determination of photoluminescence quantum yields of luminescent reporters
(2015)
A crucial variable for methodical performance evaluation and comparison of luminescent reporters is the photoluminescence quantum yield (Φ pl). This quantity, defined as the number of emitted photons per number of absorbed photons, is the direct measure of the efficiency of the conversion of absorbed photons into emitted light for small organic dyes, fluorescent proteins, metal–ligand complexes, metal clusters, polymeric nanoparticles, and semiconductor and up-conversion nanocrystals. Φ pl determines the sensitivity for the detection of a specific analyte from the chromophore perspective, together with its molar-absorption coefficient at the excitation wavelength. In this review we discuss different optical and photothermal methods for measuring Φ pl of transparent and scattering systems for the most common classes of luminescent reporters, and critically evaluate their potential and limitations. In addition, reporter-specific effects and sources of uncertainty are addressed. The ultimate objective is to provide users of fluorescence techniques with validated tools for the determination of Φ pl, including a series of Φ pl standards for the ultraviolet, visible, and near-infrared regions, and to enable better judgment of the reliability of literature data.