Filtern
Dokumenttyp
Sprache
- Englisch (2)
Referierte Publikation
- ja (2) (entfernen)
Schlagworte
- Leaching (2) (entfernen)
Leaching tests are fundamental tools for the assessment of long-term impact of contaminated waste materials on the soil-groundwater pathway. Experiments were carried out in the framework of standardization and validation of column percolation and batch test procedures, in particular concerning the stipulation of the experimental setup. The colloid release of column and batch experiments was compared and the influence of different column filling heights (12.5–50 cm) on the release of polycyclic aromatic hydrocarbons (PAH) from soil was studied, as well as the effect of varying contact times (2.5–16 h) on the release of chromium from construction and demolition (C&D) waste and municipal solid waste incineration (MSWI) bottom ash. The results indicate that filtration of the eluate, which is required for batch tests, does not always allow the simulation of the actual colloid amount in soil pore water. Medium column heights four times the inner diameter of the column seemed to provide reasonable equilibrium adjustment conditions and avoid major biodegradation. The release of chromium was only marginally affected by the contact time, varied between 0.115 and 0.150 mg/kg for demolition waste eluate at a liquid-to-solid ratio of approximately 5 L/kg.
Stir bar sorptive extraction (SBSE) is an equilibrium extraction method used amongst others for the analysis of polycyclic aromatic hydrocarbons (PAH) in aqueous samples. We compared SBSE to liquid–liquid extraction (LLE) for aqueous eluates obtained from batch and column tests of PAH contaminated soils to check whether SBSE might be considered as an alternative sample preparation method. We used soils with different particle size distribution, organic matter content, and resulting eluate turbidity to test the sample preparation methods on eluates with matrices of varying complexity. Furthermore, we studied the influence of diluted organic matter (DOM) on the PAH sorption process to the polymer coating of the stir bar during SBSE. In the majority of cases, we found higher PAH concentrations (up to 288%) with SBSE than with LLE. The turbidity correlates with the difference in PAH results, i.e. the greater the turbidity in the eluate, the more PAH we found with SBSE compared to LLE. We observed no similar trend regarding the amount of total organic carbon (TOC). The presence of DOM in the eluate seems to hamper the SBSE slightly, the PAH recovery varied between 82 and 104%.