We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using
these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ∼3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ∼5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ∼4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. We also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.
The lead authors failed to name two collaborators as co-authors. The authors listed should include:
Miss Claudia L. Compean-Gonzalez (ORCID:
0000-0002-2367-8450) and Dr. Giacomo Ceccone (ORCID:
0000-0003-4637-0771).
These co-authors participated in VAMAS project A27, provided data that were analyzed and presented in this publication (and supporting information), and reviewed the manuscript before submission.
We analyse electromotive force measurements of concentration cells using non-equilibrium thermodynamics, and determine the transference coefficients of ion-exchange membranes in aqueous KCl solutions. By taking advantage of the analytical expression for the permselectivity, we extract transport coefficients with high accuracy. The transport number of K+ and the transference coefficient of water in the Selemion CMVN cationexchange membrane are found to be 100𝑡K+ = 99.59 ± 0.56 and 𝑡𝑤 = 3.69 ± 0.40 respectively, while for the Selemion AMVN anion-exchange membrane they are 100𝑡Cl− = 100.21 ± 0.37 and 𝑡𝑤 = −3.75 ± 0.27. These results suggest that the membranes are perfectly selective to the target ion, and that each ion carries 3-4 water molecules through the membrane, which reduces the membrane permselectivity. In these concentration cells, the electrical potential contribution of the membrane alone was more easily isolated with bare Ag/AgCl electrodes without reference solutions and liquid junction plugs. Additionally, we find a large contribution to the measured concentration cell voltage from concentration gradients across the porous plug of the reference electrode, which cannot be explained by Henderson’s equation alone. For most of the concentration range, the transport number of the porous plug is determined to be 100𝑡K+ = 49.43 ± 0.78 with negligible water transport, similar to literature values for bulk electrolyte. In dilute electrolyte solutions with concentrations below 0.1 mol kg−1, the plug shows anomalous behaviour consistent with an increase in K+ selectivity and water co-transport.
We report the results of a Versailles Project on Advanced Materials and Standards (VAMAS) interlaboratory study on the measurement of the shell thickness and chemistry of nanoparticle coatings. Peptide-coated gold particles were supplied to laboratories in two forms: a colloidal suspension in pure water and particles dried onto a silicon wafer. Participants prepared and analyzed these samples using either X-ray photoelectron spectroscopy (XPS) or low energy ion scattering (LEIS). Careful data analysis revealed some significant sources of discrepancy, particularly for XPS. Degradation during transportation, storage, or sample preparation resulted in a variability in thickness of 53%. The calculation method chosen by XPS participants contributed a variability of 67%. However, variability of 12% was achieved for the samples deposited using a single method and by choosing photoelectron peaks that were not adversely affected by instrumental transmission effects. The study identified a need for more consistency in instrumental transmission functions and relative sensitivity factors since this contributed a variability of 33%. The results from the LEIS participants were more consistent, with variability of less than 10% in thickness, and this is mostly due to a common method of data analysis. The calculation was performed using a model developed for uniform, flat films, and some participants employed a correction factor to account for the sample geometry, which appears warranted based upon a simulation of LEIS data from one of the participants and comparison to the XPS results.