Filtern
Dokumenttyp
- Vortrag (2)
- Posterpräsentation (2)
- Zeitschriftenartikel (1)
Sprache
- Englisch (5)
Schlagworte
- Immunoassay (5) (entfernen)
Organisationseinheit der BAM
Eingeladener Vortrag
- nein (2)
An immunochromatographic assay for the determination of bisphenol a releases from plastic materials
(2018)
Background. The worldwide increase in the use of bisphenol A (BPA), a monomer commonly used to manufacture polycarbonate plastic products and the epoxy resins that line metal cans, has resulted in an increased human exposure because both products come in contact with food and beverages. Since BPA is an endocrine disruptor excessive exposure could affect human reproductive function. In response, various countries have adopted a range of measures, from voluntary reductions to outright bans of BPA in some products, mostly in baby bottles and containers for canned foods. Nonetheless, consumers would certainly appreciate a quick test for their own assessment of contaminations by bisphenol A.
Methods. An immunochromatographic test strip was developed. This lateral-flow immunoassay (LFIA) is based on anti-BPA antibodies (from mouse) conjugated with gold nanoparticles as the marker, deposited in an elaborate pad. To form control and test zones, anti-mouse antibody and a BPA-BSA conjugate were spotted on the nitrocellulose membrane, respectively.
Results. Negative samples are revealed by red lines both in the test and control zones, respectively, whereas positive samples produce a single red line only in the control zone. The limit of detection (LOD) was found to be 0.05 µg/l, visually detected by the naked eye within 5 minutes. In addition, the intensities at the test line can be read by dedicated lateral flow readers (opTrilyzer® and Cube by opTricon, Berlin) for a more precise and documented determination.
Conclusion. Pregnancy-test like strips in combination with hand-held readers provide a simple and versatile tool to determine the presence of bisphenol A quantitatively, making it a very attractive analytical approach especially for on-site applications at critical points, such as environmental analysis, consumer protection, and materials testing.
Diclofenac (DCF) is a non-steroidal anti-inflammatory drug (NSAID) with analgetic, anti-inflammatory, and antipyretic properties. The mechanism of action of diclofenac, like that of other NSAIDs, involves inhibition of cyclooxygenase (COX-1 and COX-2). Another pharmacological effect is preventing of prostaglandin synthesis in vitro. Prostaglandins are mediators of inflammation, because diclofenac is an inhibitor of prostaglandin synthesis.
A method has been developed to analyse for diclofenac (DCF) in the milk.
Bisphenol A (BPA) is a common industrial chemical that is widely used as a monomer or additive in the production of polycarbonate plastics and other polymeric materials. The primary way of exposure to BPA for most people is assumed to be a direct con-tamination of food and water through use of containers, bottles, and other plastic stor-age. BPA has been identified as an important endocrine disrupting compound (EDC). It can interfere with hormonal activities like biosynthesis, metabolism and elimination of natural blood-borne hormones. Moreover, BPA can originate environmental problems. A spectrum of methods have been developed with the aim of determining BPA in water. Immunoassays appear to comply with sensitivity, rapidity, and low cost requirements for effective monitoring.
In this work a comparative analysis was conducted of the effect of temperature and the choice of buffers, as well as the substrate at various stages of an ELISA (enzyme-linked immunosorbent assay). The method has been optimized and has shown good repeatability and sensitivity. The results obtained from ELISA will be used as the basis for the development of a Lateral Flow ImmunoAssay (LFIA).
One of the most important chemicals used in the production of polymer plastics and coatings is bisphenol A. However, despite the large number of studies on the toxicity and hormonal activity of BPA, there are still open questions and thus considerable media attention regarding BPA toxicity. Hence, it is necessary to develop a sensitive, simple, cost-efficient, specific, portable, and rapid method for monitoring bisphenol A and for high sample throughput and on-site screening analysis. Lateral flow immunoassays have potential as rapid tests for on-site screening. To meet sensitivity criteria, they must be carefully optimized. A latex microparticle-based LFIA for detection of BPA was developed. The sensitivity of the assay was improved by non-contact printing of spot grids as the control and test lines with careful parameter optimization. Results of the test could be visually evaluated within 10 min with a visual cut-off of 10 µg/L (vLOD). Alternatively, photographs were taken, and image analysis performed to set up a calibration, which allowed for a calculated limit of detection (cLOD) of 0.14 µg/L. The method was validated for thermal paper samples against ELISA and LC–MS/MS as reference methods, showing good agreement with both methods