Filtern
Dokumenttyp
- Zeitschriftenartikel (12)
- Beitrag zu einem Tagungsband (1)
- Sonstiges (1)
Sprache
- Englisch (13)
- Mehrsprachig (1)
Schlagworte
- SAXS (5)
- Nanoparticle (4)
- Small-angle X-ray scattering (4)
- Biofilm (2)
- Nano (2)
- Nanomaterials (2)
- Nanoparticles (2)
- Single particle ICP-MS (2)
- Antimicrobials (1)
- BODIPY (1)
- Bacteria (1)
- Bundesoberbehörden (1)
- Calibration (1)
- Characterization (1)
- Corrosion (1)
- Dissolution (1)
- Dye (1)
- Ecotoxicity (1)
- Exposure (1)
- Fluorescence (1)
- Forschungsstrategie (1)
- Hydrodynamic chromatography (HDC) (1)
- Innovative Werkstoffe (1)
- Iposomes (1)
- MIC (1)
- Matrix (1)
- Microdroplet generator (1)
- Microorganism (1)
- Nano-carrier (1)
- Nanomaterialien (1)
- Nanon (1)
- Nanoparticle characterization (1)
- Nanopatricle (1)
- Ph (1)
- Photodynamic therapy (1)
- Polymer (1)
- Quantum yield (1)
- Reference (1)
- Sensor (1)
- Signal enhancement (1)
- Small-angle x-ray scattering (1)
- SpICP-MS (1)
- Spectrometer (1)
- Standardization (1)
- Synthesis (1)
- Toxicity (1)
- Validation (1)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (5)
- 1.1 Anorganische Spurenanalytik (4)
- 6 Materialchemie (4)
- 6.5 Synthese und Streuverfahren nanostrukturierter Materialien (4)
- P Präsident (3)
- P.0 Präsident und andere (3)
- 1.2 Biophotonik (1)
- 4 Material und Umwelt (1)
- 4.1 Biologische Materialschädigung und Referenzorganismen (1)
- 6.3 Strukturanalytik (1)
Development and market introduction of new nanomaterials trigger the need for an adequate risk assessment of such products alongside suitable risk communication measures. Current application of classical and new nanomaterials is analyzed in context of regulatory requirements and standardization for chemicals, food and consumer products. The challenges of nanomaterial characterization as the main bottleneck of risk assessment and regulation are presented. In some areas, e.g., quantification of nanomaterials within complex matrices, the establishment and adaptation of analytical techniques such as laser ablation inductively coupled plasma mass spectrometry and others are potentially suited to meet the requirements. As an example, we here provide an approach for the reliable characterization of human exposure to nanomaterials resulting from food packaging. Furthermore, results of nanomaterial toxicity and ecotoxicity testing are discussed, with concluding key criteria such as solubility and fiber rigidity as important parameters to be considered in material development and regulation. Although an analysis of the public opinion has revealed a distinguished rating depending on the particular field of application, a rather positive perception of nanotechnology could be ascertained for the German public in general. An improvement of material characterization in both toxicological testing as well as end-product control was concluded as being the main obstacle to ensure not only safe use of materials, but also wide acceptance of this and any novel technology in the general public.
Among the different tested endpoints, Al- and Ticontaining nanomaterials did notshowany toxicity in intestinal cell lines in vitro. Nevertheless, this absence of effect was not due to an absence of exposure, since particle-specific uptake was reported.
Metal particle uptake over a long time period might therefore be relevant for risk assessment of aluminum- and titanium-containing food products.
Aluminum has gathered toxicological Attention based on relevant human exposure and its suspected hazardous potential. Nanoparticles from food supplements or Food contact materials may reach the human gastrointestinal tract.
Here, we monitored the physicochemical fate of aluminum containing nanoparticles and aluminum ions when passaging an in vitro model of the human gastrointestinal tract. Smallangle X-ray scattering (SAXS), transmission electron microscopy (TEM), ion beam microscopy (IBM), secondary ion beam mass spectrometry (TOF-SIMS), and inductively coupled plasma mass spectrometry (ICP-MS) in the singleparticle mode were employed to characterize two aluminumcontaining nanomaterials with different particle core materials (Al0, γAl2O3) and soluble AlCl3. Particle size and shape remained unchanged in saliva, whereas strong Agglomeration of both aluminum nanoparticle species was observed at low pH in gastric fluid together with an increased ion release. The levels of free aluminum ions decreased in intestinal fluid and the particles deagglomerated, thus liberating primary particles again. Dissolution of nanoparticles was limited and substantial changes of their shape and size were not detected. The amounts of particle-associated phosphorus, chlorine, potassium, and calcium increased in intestinal fluid, as compared to nanoparticles in standard dispersion.
Interestingly, nanoparticles were found in the intestinal fluid after addition of ionic aluminum. We provide a comprehensive characterization of the fate of aluminum nanoparticles in simulated gastrointestinal fluids, demonstrating that orally ingested nanoparticles probably reach the intestinal epithelium. The balance between dissolution and de novo complex formation should be considered when evaluating nanotoxicological experiments.
The application of appropriate analytical techniques is essential for nanomaterial (NM) characterization. In this study, we compared different analytical techniques for NM analysis. Regarding possible adverse health effects, ionic and particulate NM effects have to be taken into account. As NMs behave quite differently in physiological media, special attention was paid to techniques which are able to determine the biosolubility and complexation behavior of NMs. Representative NMs of similar size were selected: aluminum (Al0) and aluminum oxide (Al2O3), to compare the behavior of metal and metal oxides. In addition, titanium dioxide (TiO2) was investigated. Characterization techniques such as dynamic light scattering (DLS) and nanoparticle tracking analysis (NTA) were evaluated with respect to their suitability for fast characterization of nanoparticle dispersions regarding a particle's hydrodynamic diameter and size distribution. By application of inductively coupled plasma mass spectrometry in the single particle mode (SP-ICP-MS), individual nanoparticles were quantified and characterized regarding their size. SP-ICP-MS measurements were correlated with the information gained using other characterization techniques, i.e. transmission electron microscopy (TEM) and small angle X-ray scattering (SAXS). The particle surface as an important descriptor of NMs was analyzed by X-ray diffraction (XRD). NM impurities and their co-localization with biomolecules were determined by ion beam microscopy (IBM) and confocal Raman microscopy (CRM). We conclude advantages and disadvantages of the different techniques applied and suggest options for their complementation. Thus, this paper may serve as a practical guide to particle characterization techniques.
Mit einer langfristigen Forschungsstrategie begleiten die für die Sicherheit von Mensch und Umwelt zuständigen Bundesoberbehörden (Umweltbundesamt, Bundesinstitut für Risikobe-wertung, Bundesanstalt für Arbeitsschutz und Arbeitsmedizin, Bundesanstalt für Materialfor-schung und -prüfung und Physikalisch-Technische Bundesanstalt) die rasch voranschreiten-de Entwicklung neuer Materialien unter den Gesichtspunkten des Arbeits-, Verbraucher- und Umweltschutzes. Die Strategie steht daher in enger Verbindung zu den öffentlichen Förder-programmen für Nanomaterialien und andere innovative Werkstoffe, z. B. des BMBF („Vom Material zur Innovation“) und der EU („Horizon 2020“).
Die Forschungsstrategie baut auf den bisherigen Ergebnissen der 2008 begonnenen und 2013 erstmals bilanzierten gemeinsamen Forschungsstrategie der Bundesoberbehörden „Nanotechnologie - Gesundheits- und Umweltrisiken von Nanomaterialien"1 auf und erweitert den Blickwinkel auch auf andere Materialinnovationen, bei denen vergleichbare Risiken für Mensch und Umwelt bestehen oder abgeklärt werden müssen. Darüber hinaus greift sie die Idee „anwendungssichere chemische Produkte“2 aus der Initiative „Neue Qualität der Arbeit“ (INQA) des Bundesministeriums für Arbeit und Soziales (BMAS) und das Konzept der nach-haltigen Chemie3 auf, das vom Bundesministerium für Umwelt, Naturschutz, Bau und Reak-torsicherheit (BMUB) unterstützt wird. Durch eine anwendungssichere und umweltverträgli-che Gestaltung innovativer Materialien und ihrer Folgeprodukte sollen nicht akzeptable Risi-ken für Mensch und Umwelt von Anfang an weitgehend ausgeschlossen werden. Dies kann erreicht werden durch
1.
die Verwendung sicherer Materialien ohne Gefahreneigenschaften für Mensch und Umwelt (direkte Anwendungssicherheit) oder
2.
eine Produktgestaltung, die über den gesamten Lebenszyklus emissionsarm und umweltverträglich ist (integrierte Anwendungssicherheit) oder
3.
eine Unterstützung des Anwenders (product stewardship) durch den Hersteller bei technischen, organisatorischen und persönlichen Schutzmaßnahmen zur sicheren Verwendung und Entsorgung des Produktes (unterstützte Anwendungssicherheit).
Die Fortschreibung der Forschungsstrategie soll als Bestandteil des Nanoaktionsplans 2020 der Bundesregierung Beiträge der Ressortforschung zu folgenden Schwerpunkten leisten:
•
Charakterisierung und Bewertung der Risiken von Materialinnovationen
•
Unterstützung von Forschungseinrichtungen und Unternehmen
•
Fortschreiben von Rechtsvorschriften und Praxisempfehlungen
1
http://www.baua.de/nn_47716/de/Themen-von-A-Z/Gefahrstoffe/Nanotechnologie/pdf/Forschungsstrategie.pdf
2 http://www.baua.de/de/Themen-von-A-Z/Gefahrstoffe/Nachhaltige-Chemie/Nachhaltige-Chemie.html
3
http://www.umweltbundesamt.de/themen/chemikalien/chemikalien-management/nachhaltige-chemie
2
•
Gesellschaftliche Akzeptanz
Die Forschungsstrategie soll mit Projekten und anderen forschungsnahen Aktivitäten umge-setzt werden. Dies umfasst die eigene Forschung der Häuser, die extramurale Ausschrei-bung und Vergabe von Forschungsdienstleistungen sowie die Beteiligung an vorwiegend öffentlich geförderten Drittmittelprojekten. Hinzu kommen Aktivitäten im Rahmen der Politik-beratung und der hoheitlichen Aufgaben. Mit inter- und transdisziplinären Ansätzen soll die Risiko- und Sicherheitsforschung enger mit der Innovationsforschung und Materialentwick-lung verknüpft werden. Die Forschungsstrategie ist aufgrund der raschen Entwicklungen auf diesem Gebiet für den Zeitraum bis 2020 angelegt. Die Forschungsziele adressieren die in diesem Zeitraum voraussichtlich umsetzbaren Forschungsansätze. Die Forschungsstrategie wird durch einen Arbeitskreis begleitet und spätestens mit Ablauf des Nanoaktionsplans 2020 evaluiert und angepasst.
Uptake and molecular impact of aluminum-containing nanomaterials on human intestinal caco-2 cells
(2018)
Aluminum (Al) is one of the most common elements in the earth crust and increasingly used in food, consumer products and packaging. Its hazard potential for humans is still not completely understood. Besides the metallic form, Al also exists as mineral, including the insoluble oxide, and in soluble ionic forms. Representatives of these three species, namely a metallic and an oxidic species of Al-containing nanoparticles and soluble aluminum chloride, were applied to human intestinal cell lines as models for the intestinal barrier. We characterized physicochemical particle parameters, protein corona composition, ion release and cellular uptake. Different in vitro assays were performed to determine potential effects and molecular modes of Action related to the individual chemical species. For a deeper insight into signaling processes, microarray transcriptome analyses followed by bioinformatic data analysis were employed. The particulate Al species showed different solubility in biological media. Metallic Al nanoparticles released more ions than Al2O3 nanoparticles, while AlCl3 showed a mixture of dissolved and agglomerated particulate entities in biological media. The protein corona composition differed between both nanoparticle species. Cellular uptake, investigated in transwell experiments, occurred predominantly in particulate form, whereas ionic Al was not taken up by intestinal cell lines. Transcellular transport was not observed. None of the Al species showed cytotoxic effects up to 200 mg Al/mL. The transcriptome analysis indicated mainly effects on oxidative stress pathways, xenobiotic metabolism and metal homeostasis. We have shown for the first time that intestinal cellular uptake of Al occurs preferably in the particle form, while toxicological effects appear to be ion-related.
Aluminum (Al) can be taken up from food, packaging, or the environment and thus reaches the human gastrointestinal tract. Its toxic potential after oral uptake is still discussed. The fate of different solid and ionic Al species during the passage through the digestive tract is the focus of this research, as well as the cellular effects caused by these different Al species. The present study combines the physicochemical processing of three recently studied Al species (metallic Al0, mineral Al2O3, and soluble AlCl3) in artificial digestion fluids with in vitro cell systems for the human intestinal barrier. Inductively coupled plasma mass spectrometry (ICP-MS) and small-angle X-ray scattering (SAXS) methods were used to characterize the Al species in the artificial digestion fluids and in cell culture medium for proliferating and differentiated intestinal Caco-2 cells. Cytotoxicity testing and cellular impedance measurements were applied to address the effects of digested Al species on cell viability and cell proliferation. Microarray-based transcriptome analyses and quantitative real-time PCR were conducted to obtain a deeper insight into cellular mechanisms of action and generated indications for cellular oxidative stress and an influence on xenobiotic metabolism, connected with alterations in associated signaling pathways. These cellular responses, which were predominantly caused by formerly ionic Al species and only at very high concentrations, were not impacted by artificial digestion. A two-directional conversion of Al between ionic species and solid particles occurred throughout all segments of the gastrointestinal tract, as evidenced by the presence of nanoscaled particles. Nevertheless, this presence did not increase the toxicity of the respective Al species.
Iron oxides used as food colorants are listed in the European Union with the number E172. However, there are no specifications concerning the fraction of nanoparticles in these pigments.
Here, seven E172 products were thoroughly characterized. Samples of all colors were analyzed with a Broad spectrum of methods to assess their physico-chemical properties. Small-Angle X-ray Scattering (SAXS), Dynamic Light Scattering (DLS), Transmission Electron Microscopy (TEM), zeta-potential, Inductively Coupled Plasma-Mass Spectrometry (ICP-MS), X-ray diffraction (XRD), Brunauer-Emmett-Teller analysis (BET), Asymmetric Flow Field-Flow Fractionation (AF4) and in vitro cell viability measurements were used.
Nanoparticles were detected in all E172 samples by TEM or SAXS measurements. Quantitative results from both methods were comparable. Five pigments were evaluated by TEM, of which four had a size median below 100 nm, while SAXS showed a size median below 100 nm for six evaluated pigments. Therefore, consumers May be exposed to iron oxide nanoparticles through the consumption of food pigments.
Biofilms are ubiquitous in nature and in the man-made environment. Given their harmful effects on human health, an in-depth understanding of biofilms and the monitoring of their formation and growth are important. Particularly relevant for many metabolic processes and survival strategies of biofilms is their extracellular pH. However, most conventional techniques are not suited for minimally invasive pH measurements of living biofilms. Here, a fluorescent nanosensor is presented for ratiometric measurements of pH in biofilms in the range of pH 4.5–9.5 using confocal laser scanning microscopy. The nanosensor consists of biocompatible polystyrene nanoparticles loaded with pH-inert dye Nile Red and is surface functionalized with a pH-responsive fluorescein dye. Its performance was validated by fluorometrically monitoring the time-dependent changes in pH in E. coli biofilms after glucose inoculation at 37 °C and 4 °C. This revealed a temperature-dependent decrease in pH over a 4-h period caused by the acidifying glucose metabolism of E. coli. These studies demonstrate the applicability of this nanosensor to characterize the chemical microenvironment in biofilms with fluorescence methods.
Metal-containing nanoparticles (NP) can be characterized with inductively coupled plasma mass spectrometers (ICP-MS) in terms of their size and number concentration by using the single-particle mode of the instrument (spICP-MS). The accuracy of measurement depends on the setup, operational conditions of the instrument and specific parameters that are set by the user. The transport efficiency of the ICP-MS is crucial for the quantification of the NP and usually requires a reference material with homogenous size distribution and a known particle number concentration.
Currently, NP reference materials are available for only a few metals and in limited sizes. If particles are characterized without a reference standard, the results of both size and particle number may be biased. Therefore, a dual-inlet Setup for characterizing nanoparticles with spICP-MS was developed to overcome this problem. This setup is based on a conventional introduction system consisting of a pneumatic nebulizer (PN) for nanoparticle solutions and a microdroplet Generator (μDG) for ionic calibration solutions. A new and flexible interface was developed to facilitate the coupling of μDG, PN and the ICP-MS system. The interface consists of available laboratory components and allows for the calibration, nanoparticle (NP) characterization and cleaning of the arrangement, while the ICP-MS instrument is still running.
Three independent analysis modes are available for determining particle size and number concentration. Each mode is based on a different calibration principle.
While mode I (counting) and mode III (μDG) are known from the literature, mode II (sensitivity), is used to determine the transport efficiency by inorganic ionic Standard solutions only. It is independent of NP reference materials. The μDG based inlet system described here guarantees superior analyte sensitivities and, therefore, lower detection limits (LOD). The size dependent LODs achieved are less than 15 nm for all NP (Au, Ag, CeO2) investigated.
Nano-carrier systems such as liposomes have promising biomedical applications. Nevertheless, characterization of these complex samples is a challenging analytical task. In this study a coupled hydrodynamic chromatography-single particle-inductively coupled plasma mass spectrometry (HDC-spICP-MS) approach was validated based on the technical specification (TS) 19590:2017 of the international organization for standardization (ISO). The TS has been adapted to the hyphenated setup. The quality criteria (QC), e.g., linearity of the calibration, transport efficiency, were investigated. Furthermore, a cross calibration of the particle size was performed with values from dynamic light scattering (DLS) and transmission electron microscopy (TEM). Due to an additional Y-piece, an online-calibration routine was implemented. This approach allows the calibration of the ICP-MS during the dead time of the chromatography run, to reduce the required time and enhance the robustness of the results. The optimized method was tested with different gold nanoparticle (Au-NP) mixtures to investigate the characterization properties of HDC separations for samples with increasing complexity. Additionally, the technique was successfully applied to simultaneously determine both the hydrodynamic radius and the Au-NP content in liposomes. With the established hyphenated setup, it was possible to distinguish between different subpopulations with various NP loads and different hydrodynamic diameters inside the liposome carriers.
Bacterial biofilms can pose a serious health risk to humans and are less susceptible
to antibiotics and disinfection than planktonic bacteria. Here, a novel method
for biofilm eradication based on antimicrobial photodynamic therapy utilizing
a nanoparticle in conjunction with a BODIPY derivative as photosensitizer was
developed. Reactive oxygen species are generated upon illumination with
visible light and lead to a strong, controllable and persistent eradication of
both planktonic bacteria and biofilms. One of the biggest challenges in biofilm
eradication is the penetration of the antimicrobial agent into the biofilm and
its matrix. A biocompatible hydrophilic nanoparticle was utilized as a delivery
system for the hydrophobic BODIPY dye and enabled its accumulation within the
biofilm. This key feature of delivering the antimicrobial agent to the site of action
where it is activated resulted in effective eradication of all tested biofilms. Here,
3 bacterial species that commonly form clinically relevant pathogenic biofilms
were selected: Escherichia coli, Staphylococcus aureus and Streptococcus
mutans. The development of this antimicrobial photodynamic therapy tool for
biofilm eradication takes a promising step towards new methods for the much
needed treatment of pathogenic biofilms.
A broad range of inorganic nanoparticles (NPs) and their dissolved ions possess a possible toxicological risk for human health and the environment. Reliable and robust measurements of dissolution effects may be influenced by the sample matrix, which challenges the analytical method of choice. In this study, CuO NPs were investigated in several dissolution experiments. Two analytical techniques (dynamic light scattering (DLS) and inductively-coupled plasma mass spectrometry (ICP-MS)) were used to characterize NPs (size distribution curves) time-dependently in different complex matrices (e.g., artificial lung lining fluids and cell culture media). The advantages and challenges of each analytical approach are evaluated and discussed. Additionally, a direct-injection single particle (DI sp)ICP-MS technique for assessing the size distribution curve of the dissolved particles was developed and evaluated. The DI technique provides a sensitive response even at low concentrations without any dilution of the complex sample matrix. These experiments were further enhanced with an automated data evaluation procedure to objectively distinguish between ionic and NP events.
With this approach, a fast and reproducible determination of inorganic NPs and ionic backgrounds can be achieved. This study can serve as guidance when choosing the optimal analytical method for NP characterization and for the determination of the origin of an adverse effect in NP toxicity.
This study reports on the development of a single-particle (sp) inductively coupled plasma mass spectrometry (ICP-MS) technique suitable for the multi-mode determination of nanoparticle (NP) metal mass fraction and number concentration. The described technique, which is based on a dual inlet System consisting of a pneumatic nebulizer (PN) and a microdroplet generator (MDG), allows for the sequential introduction of ionic metal calibrant solutions and nanoparticle suspensions via all combinations of the two inlets; thus allowing for a combination of three independent modes of analysis. A novel interface, assembled using standard analytical components (a demountable quartz ICP-MS torch, flexible nonconducting silicon tubing and various connectors), was used to interface the dual inlet system to an ICP-MS. The interface provided improved functionality, compared to a previous design. It is now possible to conveniently exchange and introduce standard solutions and samples via all inlet combinations, analyze them, and also wash the sample inlet systems while the whole setup is still connected to an operating ICP-MS. This setup provided seamless and robust operation in a total of three analysis modes, i.e. three ways to independently determine the metal mass fraction and NP number concentration. All three analyses modes could be carried out within a single analytical run lasting approximately 20 min.
The unique feature of the described approach is that each analysis mode is based on a different.