Filtern
Erscheinungsjahr
Dokumenttyp
Schlagworte
- Computed tomography (6)
- DIRECTT (3)
- Missing wedge (3)
- Computertomographie (2)
- Computertomographie (CT) (2)
- Darkfield imaging (2)
- Electron tomography (2)
- Elektronentomographie (2)
- Iterative reconstruction (2)
- Magnetic domains (2)
Organisationseinheit der BAM
Charakterisierung von Katalysatormaterialien für Brennstoffzellen mittels Elektronentomografie
(2010)
Zur Optimierung moderner Katalysatoren für Brennstoffzellen werden diese elektronen-tomografisch charakterisiert. Die Elektronentomografie ermöglicht einzigartige Einblicke in die Nanometer-Strukturen der metallischen Katalysatorpartikel, die auf einem elektrisch leitenden, inerten Kohlenstoffträger abgeschieden werden. Die dreidimensional bildgebende Methode ermöglicht über qualitative Untersuchungen hinaus detaillierte quantitative Form- und Strukturanalysen der Katalysatormaterialien. So werden beispielsweise die Positionen der Katalysatorpartikel relativ zum Trägermaterial analysiert. Ihre Form und Einbettung in den Träger, welche die für die katalytische Reaktion maßgebliche "freie Oberfläche" definieren, werden bestimmt. Die Elektronentomografie ermöglicht somit quantitative Vergleiche zwischen verschiedenen Katalysatormaterialien und Herstellungsverfahren. Sie erweitert die Möglichkeiten der Korrelation gewünschter elektrochemischer Eigenschaften mit der Nanostruktur dieser Materialien und macht so weitere Optimierungen der Katalysatormaterialien möglich.
Als Alternative zur Neutronentomographie wird das Potenzial der Computertomographie (CT) mit inkohärenter Röntgen-Streustrahlung (Compton-Streuung) untersucht. Die gleichzeitige Abbildung von Materialien sehr unterschiedlicher Dichten (Ordnungszahlen) ist eine wiederkehrende Herausforderung für die Radiologie und die Computertomographie mit Röntgenstrahlung. Die Messungen ergeben asymmetrische Projektionsprofile für Sinogramme der Streuintensität. Am Beispiel verschiedener Polymere (Polyethylen, Polyamid, PVC), Glas und Holz wird in den Tomogrammen ein hochaufgelöster 'Comptonkontrast' vergleichbarer Dynamik erreicht, während der simultan gemessene 'Absorptionskontrast' ausschließlich die starken Absorber (Glas und PVC) zeigt. Der Vergleich mit ähnlich auflösender Neutronentomographie zeigt ähnliche Kontraste und eröffnet mithin die Möglichkeit, diese künftig durch Compton-Tomographie im Labormaßstab zu ersetzen.
Carbon fiber based felt materials are widely used as gas diffusion layer (GDL) in fuel cells. Their transport properties can be adjusted by adding hydrophobic agents such as polytetrafluoroethylene (PTFE). We present a synchrotron X-ray tomographic study on the felt material Freudenberg H2315 with different PTFE finishing. In this study, we analyze changes in microstructure and shape of GDLs at increasing degree of compression which are related to their specific PTFE load. A dedicated compression device mimicking the channel-land pattern of the flowfield is used to reproduce the inhomogeneous compression found in a fuel cell. Transport relevant geometrical parameters such as porosity, pore size distribution and geometric tortuosity are calculated and consequences for media transport discussed. PTFE finishing results in a marked change of shape of compressed GDLs: surface is smoothed and the invasion of GDL fibers into the flow field channel strongly mitigated. Furthermore, the PTFE impacts the microstructure of the compressed GDL. The number of available wide transport paths is significantly increased as compared to the untreated material. These changes improve the transport capacity liquid water through the GDL and promote the discharge of liquid water droplets from the cell.
In this investigation, synchrotron X-ray imaging was used to investigate the water distribution inside newly developed gas diffusion media in polymer electrolyte membrane fuel cells. In-situ radiography was used to reveal the relationship between the structure of the microporous layer (MPL) and the water flow in a newly developed MPL equipped with randomly arranged holes. A strong influence of these holes on the overall water transport was found. This contribution provides a brief overview to some of our recent activities on this research field.
A strategy to mitigate typical reconstruction artefacts in missing wedge computed tomography is presented. These artefacts appear as elongations of reconstructed details along the mean direction (i.e. the symmetry centre of the projections). Although absent in standard computed tomography applications, they are most prominent in advanced electron tomography and also in special topics of X-ray and Neutron tomography under restricted geometric boundary conditions. We investigate the Performance of the DIRECTT (Direct Iterative Reconstruction of Computed Tomography Trajectories) algorithm to reduce the directional artefacts in standard procedures. In order to be sensitive to the anisotropic nature of missing wedge artefacts, we investigate isotropic substructures of metal foam as well as circular disc models. Comparison is drawn to filtered backprojection and algebraic techniques. Reference is made to reconstructions of complete data sets. For the purpose of assessing the reconstruction Quality, Fourier transforms are employed to visualize the missing wedge directly. Deficient reconstructions of disc models are evaluated by a length-weighted boundary orientations. The DIRECTT results are assessd at different signal-to-noise ratios by means of local and integral evaluation Parameters.
While X-ray based darkfield imaging with grating interferometers is already widely used, darkfield imaging with neutrons has still a relatively small user community focused mostly on magnetic materials. Here, we demonstrate the application of neutron darkfield imaging byTalbot-Lau type grating interferometry to fiber reinforced plastics. Common carbon and glass fiber composites have been investigated including characteristic damage structures. The darkfield images show a strong signal response caused by fiber delamination, suitable fiber direction, particles, pores and cracks. The basic principles of neutron darkfield imaging applied to fiber composites are highlighted.
Incomplete tomographic data sets such as limited view (missing wedge) data represent a well-known challenge
for reconstruction algorithms, since they unavoidably lead to substantial image artefacts. Such data sets may
occur in industrial computed tomography of limited access (e.g. extended components, fixed objects), directional
opacity, limited sample life time or laminographic set-up. We present strategies to effectively suppress the
typical elongation artefacts (e.g. lemon-like deformed pores) by our iterative algorithm DIRECTT which offers
the opportunity to vary the versatile reconstruction parameters within each cycle. Those strategies are applied to
experimental data obtained from metallic foams as well as model simulations. Comparison is drawn to state-ofthe-
art techniques (filtered backprojection and algebraic techniques). Further reference is made to reconstructions
of complete data sets serving as gold standards. For quantitative assessment of the reconstruction
quality adapted techniques based on spatial statistics are introduced.
Typische 'Missing Wedge'(MW)-Artefakte in Rekonstruktionen der Computertomografie können mit dem iterativen DIRECTT-Algorithmus (Direkte iterative Rekonstruktion computertomografischer Trajektorien) unterdrückt werden. Die durch fehlende Projektionswinkel bedingten MW-Restriktionen betreffen bisher nur Sonderapplikationen der Röntgen- und Neutronentomografie, müssen in der Nanometer auflösenden Elektronentomografie jedoch als Standard akzeptiert werden. Die MW-Artefakte werden besonders effektiv mit einer spezifischen DIRECTT-Prozedur partiell diskreter Zwischenlösungen beseitigt. Für die Beurteilung der Abbildungsqualität werden Rekonstruktionen von vollständigen und unvollständigen Mess- und Modell-Datensätzen erzeugt und mit Ergebnissen anderer Algorithmen (gefilterte Rückprojektion (FBP) und ART-Methoden) verglichen. Die Fourier-Transformierten der Rekonstruktionen demonstrieren die erfolgreiche Ergänzung der fehlenden Information im MW-Bereich. Die quantitative Bewertung der lokalen Rekonstruktionsqualität mit Methoden der räumlichen Statistik ergibt auch für unterschiedliche Signal-Rausch-Verhältnisse signifikante Vorteile gegenüber FBP und ART.
Wir stellen eine Prozedur vor, mit der typische 'Missing Wedge' (MW)-Artefakte in CT-Rekonstruktionen effektiv unterdrückt werden können. Dazu wird der iterative DIRECTT-Algorithmus (Direkte Iterative Rekonstruktion Computertomographischer Trajektorien) mit einigen Zyklen diskreter Rekonstruktion eingesetzt. Die Kernfunktionen des Algorithmus', die wiederholte Auswahl und Gewichtung von Elementen einer Zwischenkonstruktion, werden beibehalten. Abgesehen von Sonderfällen der Röntgen- und Neutronentomographie tritt die MW-Restriktion (neben einer Vielzahl anderer) in Standardkonfigurationen der Elektronentomographie auf. Um den MW-Effekt isoliert zu untersuchen und beurteilen zu können, werden hier vollständige experimentelle Datensätze einer bekannten Porenstruktur um einen Sektor beschnitten sowie MW-Rekonstruktionen von Porenmodellen erzeugt. Die Ergebnisse werden mit zurzeit verbreiteten Algorithmen (Gefilterte Rückprojektion (FBP) und ART-Varianten) verglichen. Die Bewertung im Fourierraum zeigt, dass DIRECTT die fehlende Information im MW erfolgreich ergänzt. Zur quantitativen Bewertung der lokalen Rekonstruktionsqualität werden Methoden der räumlichen Statistik eingesetzt.
Magnetic domains have been the subject of much scientific investigation since their theoretical existence was first postulated by P.-E. Weiss over a century ago. Up to now, the three-dimensional (3D) domain structure of bulk magnets has never been observed owing to the lack of appropriate experimental methods. Domain analysis in bulk matter thus remains one of the most challenging tasks in research on magnetic materials. All current domain observation methods are limited to studying surface domains or thin magnetic films. As the properties of magnetic materials are strongly affected by their domain structure, the development of a technique capable of investigating the shape, size and distribution of individual domains in three dimensions is of great importance. Here, we show that the novel technique of Talbot-Lau neutron tomography with inverted geometry enables direct imaging of the 3D network of magnetic domains within the bulk of FeSi crystals.