Large-language models (LLMs) such as GPT-4 caught the interest of many scientists. Recent studies suggested that these models could be useful in chemistry and materials science. To explore these possibilities, we organized a hackathon. This article chronicles the projects built as part of this hackathon. Participants employed LLMs for various applications, including predicting properties of molecules and materials, designing novel interfaces for tools, extracting knowledge from unstructured data, and developing new educational applications. The diverse topics and the fact that working prototypes could be generated in less than two days highlight that LLMs will profoundly impact the future of our fields. The rich collection of ideas and projects also indicates that the applications of LLMs are not limited to materials science and chemistry but offer potential benefits to a wide range of scientific disciplines.
Permeability estimation from induced polarization (IP) measurements is based on a fundamental premise that the characteristic relaxation time τ is related to the effective hydraulic radius reff controlling fluid flow. The approach requires a reliable estimate of the diffusion coefficient of the ions in the electrical double layer. Others have assumed a value for the diffusion coefficient, or postulated different values for clay versus clay-free rocks. We have examined the link between a widely used single estimate of τ and reff for an extensive database of sandstone samples, in which mercury porosimetry data confirm that reff is reliably determined from a modification of the Hagen-Poiseuille equation assuming that the electrical tortuosity is equal to the hydraulic tortuosity. Our database does not support the existence of one or two distinct representative diffusion coefficients but instead demonstrates strong evidence for six orders of magnitude of variation in an apparent Diffusion coefficient that is well-correlated with reff and the specific surface area per unit pore volume Spor. Two scenarios can explain our findings:
(1) the length scale defined by τ is not equal to reff and is likely much longer due to the control of pore-surface roughness or
(2) the range of diffusion coefficients is large and likely determined by the relative proportions of the different minerals (e.g., silica and clays) making up the rock. In either case, the estimation of reff (and hence permeability) is inherently uncertain from a single characteristic IP relaxation time as considered in this study.
The pore size distribution provides a suitable description of the pore space geometry that can be used to investigate the fractal nature of the pore space or to determine a fractal dimension. Fractal dimension describes the size of geometric objects as a function of resolution. It can be integrated into models of permeability prediction. We investigated the fractal dimension of the pore volume of 11 Eocene sandstone samples from China. This study describes an approach to use spectral induced polarisation spectra to estimate the pore size distribution and to determine the fractal dimension of the pore volume. Additionally, the fractal dimension was derived from data of the capillary pressure curves from mercury intrusion and the transversal relaxation time distribution of nuclear magnetic resonance. For samples with an effective pore radius larger than 1 μm, good agreement exists between the values of fractal dimension derived from the three different methods, which implies the identification of similar pore structures. Spectral induced polarisation can be a non-invasive laboratory technique for the estimation of the pore size distribution, but the application of the methodology for field measurements remains a challenging problem considering the limited frequency range.
In der Vergangenheit wurde immer wieder diskutiert, ob die Porenhalsverteilung poröser silikatischer Medien maßgeblich die Relaxationszeit in Messergebnissen der Spektralen Induzierten Polarisation (SIP) bestimmt und dementsprechend auch neuere Ansätze, Porenweitenverteilungen aus diesen Daten abzuleiten, zuverlässig sein können. Systematische Studien an Gesteinen mit sehr unterschiedlichen Porenverteilungen zeigten, dass in Materialien mit engen Porenhälsen (z.B. < 5 μm) vor allem oder zusätzlich zum vermuteten Porenhalspeak niederfrequente Relaxationen zu beobachten sind, deren Ursache noch unklar ist.
Unter Einbeziehung der Methoden Röntgen-Computertomografie (μ-CT), Quecksilberporosimetrie (MIP), Stickstoffabsortion, Nukleare Magnetische Resonanz, SIP und Auflichtmikroskopie untersuchen wir den Porenraum hinsichtlich der Parameter Porosität, Permeabilität und innere Oberfläche und bestimmen die geometrischen Eigenschaften wie Porenweitenverteilungen oder fraktale Dimension durch verschiedene Algorithmen. Dabei ist zu berücksichtigen, dass sich die Methoden hinsichtlich der Grenzen ihres Auflösungsvermögens unterscheiden. Mit einer Zusammenführung der Ergebnisse aller Methoden kann eine mehrere Längenskalen überdeckende Charakterisierung der Porenraumgeometrie erfolgen.
Die Anwendung und Auswertung der verschiedenen Methoden werden am Beispiel von Baumberger Kalksandstein und Bentheimer Sandstein verglichen und diskutiert.
We investigate the pore space of rock samples with respect to different petrophysical parameters using various methods, which provide data upon pore size distributions, including micro computed tomography (μ-CT), mercury intrusion porosimetry (MIP), nuclear magnetic resonance (NMR), and spectral induced polarization (SIP). The resulting cumulative distributions of pore volume as a function of pore size are compared. Considering that the methods differ with regard to their limits of resolution, a multiple length scale characterization of the pore space geometry is proposed, that is based on a combination of the results from all of these methods. The findings of this approach are compared and discussed by using Bentheimer sandstone. Additionally, we compare the potential of SIP to provide a pore size distribution with other commonly used methods (MIP, NMR). The limits of resolution of SIP depend on the usable frequency range (between 0.002 and 100 Hz). The methods with similar resolution show a similar behavior of the cumulative pore volume distribution in the overlapping pore size range. The methods μ-CT and NMR provide the pore body size while MIP and SIP characterize the pore throat size. Using this difference, the average pore body to throat ratio is determined to be about three for the Bentheimer sandstone.
Our study shows that a good agreement between the pore radii distributions can only be achieved if the curves are adjusted considering the resolution and pore volume in the relevant range of pore radii. The MIP curve with the widest range in resolution should be used as reference
Dehydration is a common process occurring in natural environments, rocks, and building materials. Suitable methods for monitoring the changing moisture content should be identified.
We have investigated the impact of dehydration of sandstones on complex conductivity spectra. Spectral induced polarization measurements were performed on five sandstone samples during evaporative drying. The complex conductivity spectra indicate considerable changes with decreasing saturation. The relationship between conductivity and saturation can be described by a power law known as the second empirical Archie equation. Separate saturation exponents have been determined for the real and imaginary parts of conductivity. The imaginary part of conductivity indicates higher saturation exponents for the investigated sandstones compared to the real part. Obviously, the saturation exponents depend on the method used for changing water saturation. Evaporative drying, which is used in our experiments, causes an increase of pore-water salinity and results in lower saturation exponents for the real part of conductivity but higher exponents for the imaginary part in comparison with the classical imbibition/Drainage technique. We evaluate a theoretical approach that considers the influence of pore water salinity on the saturation exponents of the real and imaginary parts of conductivity. The complex conductivity spectra are processed by a Debye decomposition procedure.
The resulting integrating parameters such as direct current resistivity, total chargeability, normalized chargeability, and mean relaxation time indicate a power law dependence on saturation. Our experiments indicate that the imaginary part of conductivity and normalized chargeability have a high sensitivity related to the drying process of rocks and might be suitable indicators to Monitor the changes of moisture content in sandstones.
Permeability estimation from spectral induced
polarization (SIP) measurements is based on a
fundamental premise that the characteristic relaxation
time (t) is related to the effective hydraulic radius (reff)
controlling fluid flow. The approach requires a reliable
estimate of the diffusion coefficient of the ions in the
electrical double layer. Others have assumed a value for
the diffusion coefficient, or postulated different values for
clay versus clay-free rocks. We examine the link between
t and reff for an extensive database of sandstone samples
where mercury porosimetry data confirm that reff is
reliably determined from a modification of the Hagen-
Poiseuille equation assuming that the electrical tortuosity
is equal to the hydraulic tortuosity. Our database does not
support the existence of 1 or 2 distinct representative
diffusion coefficients but instead demonstrates strong
evidence for 6 orders of magnitude of variation in an
apparent diffusion coefficient that is well correlated with
both reff and the specific surface area per unit pore
volume (Spor). Two scenarios can explain our findings:
(1) the length-scale defined by t is not equal to reff and is
likely much longer due to the control of pore surface
roughness; (2) the range of diffusion coefficients is large
and likely determined by the relative proportions of the
different minerals (e.g. silica, clays) making up the rock.
In either case, the estimation of reff (and hence
permeability) is inherently uncertain from SIP relaxation
time.
We investigate the pore space of rock samples with respect to different petrophysical parameters using various methods, which provide data on pore size distributions, including micro computed tomography (µ-CT), mercury Intrusion porosimetry (MIP), nuclear magnetic resonance (NMR), and spectral-induced polarization (SIP). The resulting cumulative distributions of pore volume as a function of pore size are compared. Considering that the methods differ with
regard to their limits of resolution, a multiple-length-scale characterization of the pore space is proposed, that is based on a combination of the results from all of these methods.
The approach is demonstrated using samples of Bentheimer and Röttbacher sandstone. Additionally, we compare the potential of SIP to provide a pore size distribution with other commonly used methods (MIP, NMR). The limits of Resolution of SIP depend on the usable frequency range (between 0.002 and 100 Hz). The methods with similar Resolution show a similar behavior of the cumulative pore volume distribution in the verlapping pore size range. We assume that µ-CT and NMR provide the pore body size while MIP and SIP characterize the pore throat size. Our study Shows that a good agreement between the pore radius distributions can only be achieved if the curves are adjusted considering the resolution and pore volume in the relevant range of pore radii. The MIP curve with the widest range in Resolution should be used as reference.