Grundsätzliches zur Frage der "UV-Beständigkeit" bzw. der "Lichtbeständigkeit" polymerer Werkstoffe
(2013)
Scrap tyres are widely reused in the form of granules as infill materials or component of sub-base layers in construction of sporting grounds such as synthetic turf areas and athletic track surfaces. The recycled rubber may contain organic and inorganic pollutants due to the presence of vulcanisation catalysts, stabilisers and other additives which can be released into soil and groundwater in the case of outdoor sports facilities. In order to evaluate the amount of potentially mobile pollutants, leaching tests can be employed. This study aimed particularly at the investigation of the feasibility of column tests using complete synthetic surface flooring or turf system assemblies. The release of zinc and polycyclic aromatic hydrocarbons (PAH) leached from components of sports surfaces containing recycled rubber granules was considered. Additionally, batch tests on coated and uncoated styrene butadiene rubber (SBR) granules aged by artificial weathering were performed to indicate its possible influence on the leaching behaviour of zinc and PAH. The chosen approach of column tests simulating typical complete synthetic sports surface installations has been proven to be feasible and robust. The time-dependent leaching behaviour and interactions between single components can be evaluated by column tests. Zinc was the most relevant contaminant in the eluates and its leachability was enhanced after accelerated ageing by artificial weathering. Leachable PAH were found in relatively low but well detectable amounts which increase by ageing as well.
Temperature is an important parameter in weathering tests. In many (photo-)chemical degradation processes a Variation of the specimen temperature by A t = + 1 °C can cause a Variation of AP(property change) by ± 8%.
Since the early eighties it is well known that some types of black panel thermometers can show temperatures that are far below the maximum surface temperature of a black specimen. Although, there were precise requirements for the black coating of the BPT, a replacement by a white coating - depending on the design of the BPT - did not really change the temperature shown by the thermometer. There was no correlation between the BPT and the specimen surface temperature.
In Europe and later at ISO the so-called black- and white-standard thermometers BST/WST were introduced. Now, there are BST and WST (ISO) and there are thermally uninsulated and insulated BPT and WPT (ASTM), partly for artificial or for outdoor exposure. And there are other adventurous procedures to determine surface temperatures.
The different types of thermometers and different procedures will be discussed and it will be shown that there is no procedure which establishes a correlation between outdoor surface temperatures and surface temperatures in artificial exposure tests.