Filtern
Erscheinungsjahr
Dokumenttyp
- Zeitschriftenartikel (92)
- Buchkapitel (2)
Referierte Publikation
- ja (94) (entfernen)
Schlagworte
- IDMS (15)
- Metrology (9)
- Traceability (9)
- ICP-MS (8)
- TIMS (8)
- Mass spectrometry (7)
- Measurement uncertainty (7)
- CCQM (6)
- Isotope dilution (5)
- Isotope reference materials (5)
Organisationseinheit der BAM
- 1 Analytische Chemie; Referenzmaterialien (43)
- 1.1 Anorganische Spurenanalytik (43)
- P Präsident (4)
- P.0 Präsident und andere (4)
- 1.3 Instrumentelle Analytik (3)
- 1.4 Prozessanalytik (3)
- 1.6 Anorganische Referenzmaterialien (3)
- S Qualitätsinfrastruktur (3)
- S.1 Qualität im Prüfwesen (3)
- 1.7 Organische Spuren- und Lebensmittelanalytik (2)
An ICP-MS equipped with collision cell, sector field and multi-collector technology has been applied to developing analytical procedures for Fe in terms of isotope ratio measurements and isotope dilution analysis. Therefore a detailed study on the reduction of molecular interferences by a variety of collision gases (He, Ar, Kr, H2, D2 and N2) was performed. The efficiency of the reduction has been checked by high resolution mass scans. The argon based interferences disturbing the determination of 54Fe and 56Fe could be completely removed when using Faraday detectors. The interferences on mass 57 could be reduced to a level which enables accurate measurements. Also, the 40Ar12C interference, which disturbs the chromium correction, could be completely removed. Reproducibilities of 0.01% could be reached for 54Fe/56Fe isotope ratios and 0.02% for 57Fe/56Fe isotope ratios. Under these measurement conditions a sensitivity of 1.2 V per 50 µg kg1 Fe is available. This corresponds to 1.5 × 109 cps per mg kg1. Based on these results highly accurate procedures for Fe isotope ratio determinations were set up, reaching a performance level superior to that of other ICP-MS instruments. Consequently, IDMS procedures were developed on this basis in order to perform certification measurements at the highest metrological level. The first application was the contribution to the Fe reference value by IMEP-12, an interlaboratory comparison with approximately 350 participants worldwide. The analysed Fe mass content is 0.2150 mg kg1 with its expanded uncertainty (k= 2) of 0.0012 mg kg1(0.56%), which is ten times less than the uncertainty of the second certification laboratory. Another application was the certification campaign of the two reference materials Tea Leaves and Polish Herbs. The results obtained with the ICP-MS procedure, 542 ± 11 mg kg1 and 543 ± 12 mg kg1, were compared with the results analysed by TIMS, 541 ± 12 mg kg1 and 541 ± 13 mg kg1, and agree very well within the stated uncertainties (k= 2). The results presented demonstrate quite well the suitability of the developed IDMS procedures for certification or reference measurements.
This article reviews the application of isotope dilution mass spectrometry (IDMS) to the field of reference material (RM) characterisation within the past 15 years, focusing on elemental and elemental species analysis. Emphasis is placed on liquid and solid RMs and IDMS measurements of the highest analytical quality. Basic principles, as well as the equation system, are being revisited. Different calibration strategies, such as single, double or triple IDMS, are critically reviewed and the achievable uncertainties are discussed. Differences in the application of thermal ionization mass spectrometry (TIMS) and inductively coupled plasma mass spectrometry (ICP-MS) are discussed as well as differences between different types of mass spectrometers, such as single collector versus multi-collector or quadrupole versus magnetic sector instruments. Possible sources of errors and bias are mentioned and correction models introduced and applied within the past years are discussed. Several examples for RM characterisations and inter-laboratory comparisons for elemental as well as elemental species analysis are shown, each demonstrating excellent analytical quality. In general, it can be stated that IDMS is the most important reference method for elemental and elemental species analysis, offering the highest accuracy and precision or smallest measurement uncertainties, when properly applied. Thus, IDMS represents by far the best suited reference method for RM characterisation. Owing to its universal applicability IDMS offers sufficient potential to follow future needs in analytical chemistry as well as in the RM sector.
The present paper describes the contribution of the Institute for Reference Materials and Measurements to the certification of B, Cd, Mg, Pb, Rb, Sr, and U amount contents in a natural water sample, in round 9 of the International Measurement Evaluation Programme (IMEP-9). The analytical procedure to establish the reference values for B, Cd, Mg, Pb, Rb, Sr, and U amount contents was based on isotope dilution inductively coupled plasma-mass spectrometry used as a primary method of measurement. Applying this procedure reference values, traceable to the SI, were obtained for the natural water sample of IMEP-9. For each of the certified amount contents presented here a total uncertainty budget was calculated using the method of propagation of uncertainties according to ISO and EURACHEM guidelines. The measurement procedures, as well as the uncertainty calculations are described for all seven elements mentioned above. In order to keep the whole certification process transparent and so traceable, the preparations of various reagents and materials as well as the sample treatment and blending, the measurements themselves, and finally the data treatment are described in detail. Explanations focus on Pb as a representative example. The total uncertainties (relative) obtained were less than 2% for all investigated elements at amount contents in the pmol/kg up to the high 7mol/kg range, corresponding to low 7g/kg and mg/kg levels.
The present paper describes the certification of the amount content of Cd, Cr and Pb in two different polyethylene materials within the third phase of the Polyethylene Elemental Reference Material (PERM) project. The analytical procedure to establish the reference values for Cd, Cr and Pb amount contents in these materials is based on isotope dilution mass spectrometry used as a primary method of measurement. Cd and Pb were measured with inductively coupled plasma-mass spectrometry and Cr with positive thermal ionization-mass spectrometry. The decomposition of the polymer matrix was carried out using a high pressure asher. Reference values for amount content, traceable to the SI-system, have been obtained for these three elements in both of the polyethylene samples of PERM. For each of the certified amount content values an uncertainty budget was calculated using the method of propagation of uncertainties according to ISO and EURACHEM guidelines. The measurement procedures, as well as the uncertainty calculations, are described for all three elements. In order to keep the whole certification process as transparent as possible, the preparations of various reagents and materials as well as the sample treatment and blending are described in detail. The mass spectrometry measurements and the data treatment are also explained carefully. The various sources of uncertainty present in the procedure are displayed in the uncertainty budgets. The obtained combined uncertainties for the amount content values were less than 2% relative (k=1) for all investigated elements. The amount contents were in the ?mol/kg range, corresponding to mg/kg levels.
A thin-layer reference material for surface and near-surface analytical methods was produced and certified. The surface density of the implanted Sb layer was determined by Rutherford backscattering spectrometry (RBS), instrumental neutron activation analysis (INAA), and inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) equipped with a multi-collector. The isotopic abundances of Sb (121Sb and 123Sb) were determined by multi-collector ICP-MS and INAA. ICP-IDMS measurements are discussed in detail in this paper. All methods produced values traceable to the SI and are accompanied by a complete uncertainty budget. The homogeneity of the material was measured with RBS. From these measurements the standard uncertainty due to possible inhomogeneities was estimated to be less than 0.78% for fractions of the area increments down to 0.75 mm2 in size. Excellent agreement between the results of the three different methods was found. For the surface density of implanted Sb atoms the unweighted mean value of the means of four data sets is 4.8121016 cm-2 with an expanded uncertainty (coverage factor k=2) of 0.0921016 cm-2. For the isotope amount ratio R (121Sb/123Sb) the unweighted mean value of the means of two data sets is 1.435 with an expanded uncertainty (coverage factor k=2) of 0.006.
The ?- branching ratio of 64Cu was determined by investigating the resulting decay products in copper doped by neutron transmutation. The numbers of 64Zn and 64Ni atoms were analyzed using isotope dilution analysis combined with thermal ionization mass spectrometry. A ?- branching ratio of (38.06±0.30)% was obtained, which agrees with the study of Kawada (Appl. Radiat. Isot. 37 (1) (1986) 7) to a higher accuracy. However, our result differs from the value cited in the NUDAT database of (39.0±0.3)%.
The present work describes the development of an existing TIMS procedure to a reference procedure for low sulfur concentration measurements in fossil fuels. With this enhanced procedure SI-traceable sulfur mass fractions below 10 mg kg-1 can be obtained. The achieved detection limit is approximately 0.2 mg kg-1. The procedure was validated by certified reference materials. The procedure was already applied to candidate reference materials and to samples analysed within projects of the Comité Consultatif pour la Quantité de Matière CCQM.
Additionally the influence of the isotopic composition on the results and its corresponding uncertainty was studied. Reference data published in the literature on the isotopic composition of sulfur were assessed.
The stable carbon and nitrogen isotopic composition of urine and milk samples from cattle under different feeding regimes were analysed over a period of six months. The isotope ratios were measured with isotope ratio mass spectrometry (IRMS). The δ13C values of milk and urine were dependent on different feeding regimes based on C3 or C4 plants. The δ13C values are more negative under grass feeding than under maize feeding. The δ13C values of milk are more negative compared to urine and independent of the feeding regime. Under grass feeding the analysed milk and urine samples are enriched in 13C relative to the feed, whereas under maize feeding the 13C/12C ratio of urine is in the same range and milk is depleted in 13C relative to the diet. The difference between the 15N/14N ratios for the two feeding regimes is less pronounced than the 13C/12C ratios. The δ15N values in urine require more time to reach the new equilibrium, whereas the milk samples show no significant differences between the two feeding regimes.